首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
目的 探讨双低对比剂联合能谱CT成像技术在门静脉成像中的应用价值,并评价其辐射剂量.方法 搜集行肝脏门静脉CT扫描的患者72例,均采用宝石能谱CT进行扫描.随机分为两组,A组为双低对比剂联合单能量成像组,共36例;B组为常规组,共36例.A组使用低浓度对比剂碘克沙醇,浓度为270 mgI/ml,低对比剂总量(按1.2 ml/kg体重计算).采用能谱扫描模式,80 kVp和140 kVp电压快速切换,通过原始数据重组出最佳单能量图像.B组使用常规对比剂碘海醇,浓度为350 mgI/ml,常规对比剂总量(按1.5ml/kg体重计算).采用螺旋扫描模式,120 kVp混合能量,得到门静脉图像.比较两组图像中门静脉主干的CT值、信噪比(SNR)、对比噪声比(CNR)及噪声,通过这些客观参数来评价图像质量,由2名高年资放射科医师采用双盲法对图像质量进行主观评分,并比较两组图像的CT容积剂量指数(CTDI)、剂量长度乘积(DLP)及有效辐射剂量(ED).对所得的数据使用SPSS 19.0统计软件进行统计学分析.结果 A组对比剂总量为(84.43±11.17) ml,B组对比剂总量为(93.50±9.53) ml,A组明显低于B组(P<0.01).A组门静脉CT值及CNR分别为(226.65±17.99) HU、5.83 ±1.64,B组门静脉CT值及CNR分别为(195.01±23.98)HU、4.00±1.64,A组门静脉CT值及CNR明显高于B组(P<0.01).两组中门静脉SNR、图像噪声及主观评分差异无统计学意义(P>0.05).A组中CTDI、DLP及ED分别为(10.32 ±2.22) mGy、(264.54±57.44) mGy·cm、(4.50±0.98) mSv,B组中CTDI、DLP及ED分别为(13.20±2.35) mGy、(363.89±75.40) mGy·cm、(6.19±1.28) mSv,A组中CTDI、DLP及ED明显低于B组(P<0.01).结论 在门静脉CT血管成像中,使用低总量、低浓度对比剂联合能谱CT单能量成像技术,在获得满足临床需求图像的同时,不仅有效地减少了对比剂的用量及提高图像的SNR,还降低了辐射剂量,具有在临床广泛推广的价值.  相似文献   

2.
目的 探讨80 kV管电压双源CT冠状动脉成像(CTCA)在低体质量指数(BMI)患者中应用的可行性.方法 240例疑有冠状动脉疾病且BMI在18.6~21.5 kg/m2的患者按数字表法随机分成A、B、C组行双源CTCA检查,分别采用120、100和80 kV管电压.对每位患者的对比剂用量、CT容积剂量指数(CTDIvol)、剂量长度乘积(DLP)、有效辐射剂量(ED)、图像噪声、冠状动脉CT值、对比度、信噪比(SNR)、对比噪声比(CNR)和图像优良指数(FOM)进行评估.同时按3分法对冠状动脉图像质量进行评分(3分为优秀,2分为一般,1分为差).扫描长度、CTDIvol、DLP、ED、对比剂用量、图像噪声、冠状动脉CT值、对比度、SNR、CNR及FOM在3组间比较均采用单因素方差分析,采集时间窗使用情况比较采用x2检验,图像质量评分比较采用Kruskal-Wallis检验.结果 3组间扫描长度及采集时间窗使用情况差异均无统计学意义(扫描长度F=2.58,采集时间窗x2=0.77,P均>0.05).A、B和C组对比剂用量(碘海醇350 mg I/ml)平均值分别为(82.0±6.4)、(76.8±6.1)和(59.1±3.5)ml,相应的CTDIvol平均值分别为(27.5±6.2)、(18.7±4.4)和(11.4±2.4) mGy,DLP平均值分别为(427.7±92.4)、(295.4±77.1)和(183.9 ±41.3)mGy·cm,ED平均值分别为(6.1±1.3)、(4.1±1.1)和(2.6±0.6) mSv,3组间对比剂用量、CTDIvol、DLP和ED差异均有统计学意义(对比剂用量、CTDIvol、DLP和ED对应的F值分别为383.08、248.13、221.05和234.81,p值均<0.01),与A和B组相比,C组对比剂用量分别下降27.9%和23.0%,ED分别下降57.4%和36.6%.A、B和C组图像噪声平均值分别为(22.6±2.2)、(26.1±3.0)和(29.1 ±3.4)HU,差异有统计学意义(F=101.32,P<0.01).A组右冠状动脉(RCA)近段的CT值、对比度、SNR、CNR及FOM分别为(438.3±66.3)HU、(517.3 ±67.8)HU、19.5±2.8、23.0±3.0和92.9±31.0,左冠状动脉主干(LMA)的CT值、对比度、SNR、CNR及FOM分别为(440.2±59.9) HU、(509.5±62.6) HU、19.6±2.6、22.7±2.9和90.1±29.7;B组RCA近段的各相应参数值分别为(534.2±68.8) HU、(628.9±70.0) HU、20.7±3.2、24.3 ±3.6和157.6±59.8,LMA的各相应参数值分别为(528.4 ±61.2) HU、(607.9±71.2) HU、20.4±3.0、23.5 ±3.4和147.6±57.6;C组RCA近段的各相应参数值分别为(602.1±78.8)HU、(696.8±83.3) HU、20.8±2.9、24.1 ±3.2和239.3 ±74.8,LMA的各相应参数值分别为(592.5±72.3) HU、(671.8±82.5) HU、20.5±2.5、23.2±3.0和221.8±65.7.C组冠状动脉CT值、对比度、SNR、CNR及FOM均未见下降.3组RCA近段的CT值、对比度、SNR、CNR及FOM比较,相应的F值分别为106.06、119.90、4.69、3.70和127.50,P值均<0.05;LMA的CY值、对比度、SNR、CNR及FOM比较相应的F值分别为111.79、101.57、2.68、1.39和123.00,P值分别<0.01、<0.01、>0.05、>0.05、<0.01.A组图像质量评分为优秀、一般和差的节段数目分别为631、330和37个,B组分别为640、323和41个,C组分别为615、348和45个,3组图像质量评分比较差异无统计学意义(x2=1.90,P>0.05).结论 对于BMI≤21.5 kg/m2的患者,80 kV管电压行双源CTCA可完成冠状动脉疾病诊断,并能够明显降低辐射剂量和对比剂用量.  相似文献   

3.
目的 探讨低kVp扫描技术在小儿心脏大血管CTA检查中降低辐射剂量的价值.方法 选取小儿先天性心脏病CTA检查病例39例分为两组,A组24例,B组1 5例.A组使用常规kVp 120,B组使用低kVp 90.记录两组病例扫描时机器自动显示的扫描长度(L)、容积CT剂量指数(CTDIvol)及剂量长度乘积(DLP).测量并计算左心房中部水平胸主动脉信噪比(SNR)、对比噪声比(CNR)以客观评价图像质量;双盲法主观评价心脏大血管后重组图像对肺动脉六分支的显示情况并给予优、良、差分级.对L、CTDIvol、DLP、E值、SNR及CNR进行t检验,主观图像质量评价采用x2检验.结果 A组和B组L分别为(10.40±1.97)cm和(9.54±1.72)cm,两组比较无统计学差异(P=0.169).A组和B组的CTDIvol分别为(11.6±0)mGy和(5.0±0)mGy,DLP为(120.67±22.55)mGy·cm和(47.68±8.61)mGy·cm,两组比较均有统计学差异(P<o.0001),B组比A组分别降低56.9%、60.5%.A组和B组SNR分别为(41.86±12.05)和(42.11±7.83)(P=0.944),CNR分别为(33.15±10.82)和(33.75±6.76)(P=0.850),两组比较无统计学差异.A组和B组的图像质量主观评判诊断满意率均达1oo%,统计学比较无差异.结论 小儿心脏大血管CTA检查使用低kVp扫描技术可以较大幅度降低辐射剂量,且不影响图像质量,具有较大的临床应用价值.  相似文献   

4.
目的:探讨低管电压结合自适应统计性迭代重建(ASIR)对仿真模体腹部CT图像质量的影响。方法对仿真模体从噪声指数(NI)=6到 NI=15间隔为1的10个 NI 进行80 kVp 扫描,50% ASIR,测量每次扫描的肝脏标准差(SD),做出 SD 与 NI 的关系图,并在图中找出 SD=10 HU 时所对应的 NI 值。然后利用此 NI 值、50% ASIR 进行20组80 kVp 扫描,利用 NI=10、滤波反投影重建(FBP)进行20组120 kVp 扫描,以此分为 A 组、B 组。比较 A 组和 B 组的 CTDIVOL 、DLP、对比噪声比(CNR)、信噪比(SNR)、质量因数(FOM);对比2组的图像质量评分。结果① A 组的 CTDIVOL 、DLP 分别为(3.96±0.04)mGy、(57.89±0.57)mGy/cm,B 组的 CTDIVOL 、DLP 分别为(6.85±0.66)mGy、(100.12±0.96)mGy/cm,A 组与 B 组差异具有显著统计学意义(P <0.01);②A 组的图像质量评分为4.15±0.59,B 组的图像质量评分为3.85±0.59,A 组与 B 组差异没有统计学意义(P >0.05);③A 组肝脏 CNR、SNR、FOM 分别为11.70±1.42、8.03±0.93、35.04±8.88,B 组肝脏 CNR、SNR、FOM 分别为6.70±0.66、6.87±0.66、6.62±1.32;A 组脾脏 CNR、SNR、FOM 分别为11.39±1.38、7.72±0.91、33.22±8.47,B 组脾脏 CNR、SNR、FOM 分别为6.84±6.53、7.00±0.67、6.89±1.34;A 组胰腺 CNR、SNR、FOM 分别为7.61±0.98、3.95±0.51、14.89±4.03,B 组胰腺 CNR、SNR、FOM 分别为3.31±0.31、3.56±0.30、2.41±5.33;A 组与 B 组 CNR、FOM 差异均具有显著统计学意义(P <0.01),A 组与 B 组间 SNR 差异均具有统计学意义(P <0.05)。结论低管电压结合 ASIR 仿真模体腹部 CT 成像不但可以降低辐射剂量,而且提高了图像质量。  相似文献   

5.
目的:探讨联合应用低管电压和低对比剂方案用于非肥胖患者门静脉成像(MSCTP)的可行性.方法:纳入接受MSCTP、体质量指数≤25 kg/m2的患者160例,采用数字法随机分为2组,每组80例.常规组管电压为120 kVp,对比剂用量为1.2 mL/kg,双低组管电压为80 kVp,对比剂用量为1.0 mL/kg.采用独立样本t检验比较各组CT剂量容积指数(CTDIvol)、有效管电流(mAs)、剂量长度乘积(DLP)、有效辐射剂量(ED)和对比剂用量、肝实质CT值(CTH)、门静脉CT值(CTp)、图像噪声(SD)、肝实质SNR(SNRH)、门静脉与肝实质CNR(CNRp)的差异;采用秩和检验比较两组图像评分.采用Kappa检验两位医师评分结果一致性.结果:双低组CTDIvol[(4.59±1.03) mGy]低于常规组CTDIvol[(7.50±1.45) mGy(P<0.05)],均有统计学差异;双低组ED[(1.71±0.50) mSv]低于常规组[(2.75±0.67) mSv(P<0.05)];双低组平均辐射剂量比常规组减少了1.05 mSv,减少38.09%;双低组图像质量评分(3.93±0.88)高于常规组[(3.33±0.81),有统计学差异(P<0.05)];双低组CTH和CTp分别为(126.74±30.59)和(223.78±45.85) HU均明显高于常规组(95.60±15.89)和(161.47±25.37) HU,差异有统计学意义(P<0.05);双低组SD(24.61±2.77) HU高于常规组(1.65±3.38) HU,P<0.05],双低组SNRH为(5.20±1.24) HU低于常规组SNRH(7.00±2.44) HU,差异有统计学差异(P<0.05),但是双低组门静脉与肝实质CNRp为(4.33±0.97) HU与常规组(4.67±1.44) HU比较差异无统计学意义(P>0.05);双低组平均对比剂用量为(66.56±2.48) mL显著低于常规组[(80.48±2.97) mL(P<0.05)],双低组平均造影剂用量较常规组减少17.30%.结论:采用80 kVp低管电压结合低剂量和对比剂方案对非肥胖患者进行MSCTP能降低辐射剂量和对比剂用量并进一步提高图像质量.  相似文献   

6.
双源CT低管电压技术在超重患者冠状动脉成像中的应用   总被引:1,自引:1,他引:0  
目的 探讨在超重患者双源CT冠状动脉成像中低管电压技术的应用价值,评价其图像质量和辐射剂量.方法 将66例接受双源CT冠状动脉检查,体质量<85 kg、且体质量指数(BMI)为25.0~30.0 ks/m2的患者完全随机化分为A、B 2组.A组30例,管电压为120 kVp;B组36例,管电压为100 kVp.所有患者均采用回顾性心电门控螺旋扫描和四维智能在线剂量调控(CARE Dose 4D)技术,严格控制扫描范围.对2组的扫描数据分别进行多种图像后处理,由影像科副主任医师和副主任技师各1名采用双盲法评估图像质量.测量并计算信噪比(SNR)、对比信噪比(CNR).记录CT容积剂量指数(CTDIvol)和剂量长度乘积(DLP),计算有效辐射剂量(ED).应用两独立样本t检验比较2组患者图像ROI的CT值、噪声、SNR、CNR、辐射剂量及对比剂用量、图像质量评分等.应用X2检验比较两组患者冠状动脉图像质量分级显示段数.应用Kappa检验判断2名评价者评分的一致性.以P<0.05为差异有统计学意义.结果 图像ROI内CT值、噪声(以标准差SD计算)、SNR测量值:A组右冠状动脉(RCA)起始部分别为(429.3±77.4)HU,24.0±8.2、21.8±9.9,左冠状动脉主干(LMA)起始部分别为(436.7±79.0)HU、19.4±7.3、22.3±9.8;B组RCA分别为(503.5±95.4)HU、34.0±12.6、21.0±10.7,LMA分别为(491.7±96.2)HU、33.4±15.5、20.6±11.4;CNR测量值:A组为24.4±10.3,B组为21.9±8.2.2组患者冠状动脉血管腔内强化平均CT值、噪声比较,B组大于A组,差异有统汁学意义(P值均<0.05);2组间SNR、CNR筹异无统计学意义(P值均>0.05);2组CTDIvol比较,A组为(42.2±13.8)mGy,B组为(20.2±6.5)mGy,差异有统计学意义(P<0.05);A组ED为(9.5±3.6)roSy,B组为(4.8±1.7)mSv,差异有统汁学意义(P<0.05);A组图像质量评分为(4.5±1.0)分,B组为(4.7±0.5)分,筹异无统计学意义(P>0.05);A绀评价383段冠状动脉,图像优良者377段(98.4%)B组评价490段冠状动脉,图像优良者483段(98.6%).结论 对于BMI在25.0~30.0 kg/m2的患者,使用100 kVp管电压配合CARE Dose 4D技术进行双源CT冠状动脉检查,可以获得较好的图像质量,并且可以显著降低辐射剂量.
Abstract:
Objective To investigate the image quality and the radiation dose of dual-source computed tomography coronary angiography by using low kilovohage combination with low tube current in overweight patients.Methods Sixty-six patients with body mass inde,(BMI)25.(0-30.0 kg/m2 and a body weight<85 kg were randomized two groups(group A and group B).Thirty patients in group A were examined with 120 kVp,and 36 patients in group B with 100 kVp.ECG-pulsing and care dose 4D for radiation dose reduction were used in all patients.All images were transferred to Siemens workstation for post processing and analysis.Two observers blimted to clinical data independently assessed the image quality of each coronary segment by using a 5-point scoring scale(5:excellent,1:no diagnostic).and measured the different image parameters including image noise,signal-to-noise ratio(SNR)and contrast-to-noise ratio (CNR).The effective dose(ED)was calculated by using CT dose volume index(CTDIvol)and the doselength product (DLP). The mean intraluminal attenuation, image noise, SNR, CNR, radiation dose,volume of contrast medium, and mean image quality scores were compared between the two groups with t test. The grading quantity of coronary artery segment was compared with Chi-square test. The interobserver agreement was determined by Kappa statistics. Results The mean intraluminal attenuation, image noise,SNR in group A were (429. 3±77.4 ) HU, 24.0±8.2, 21.8±9. 9 in right coronary artery ( RCA), and (436. 7±79. 0) HU, 19.4±7.3, 22. 3±9. 8 in left main coronary artery (LMA ), and that in group B were (503.5±95.4) HU, 34.0±12.6, 21.0±10.7 in RCA, and (491.7±96.2) HU, 33.4±15.5,20.6±11.4 in LMA. The CNR were 24.4±10.3 in group A and 21.9±8.2 in group B. The mean intraluminal attenuation and image noise were significantly higher for group B compared with group A ( P <0. 05 ). There were no difference in SNR and CNR between the two groups ( P > 0. 05 ). Estimated ED in group B was significantly lower than that in group A [CTDIvol = (42. 2±13. 8) mGy, ED = (9. 5±3.6)mSv in group A vs. CTDIvol = ( 20. 2±6.5 ) mGy, ED = (4. 8±1.7 ) mSv in group B ; each P < 0. 05 ].Mean image quality scores were not significantly different between two groups ( 4. 5±1.0 in group A vs.4. 7±0. 5 in group B, P > 0. 05 ). A total of 383 coronary artery segments were evaluated in group A and 490 segments in group B. The difference of grading quantity of coronary artery segment was no statistical significant between two groups. Conclusions 100 kVp combination with ECC-pulsing and CARE Dose 4D of dual-source CTCA was valuable for patients with BMI ranging from 25 to 30 kg/m2 which have a better image quality and low radiatiun dose.  相似文献   

7.
目的:评估自然呼吸状态下小剂量对比剂CT肺动脉成像(CTPA)的可行性及诊断肺动脉栓塞的价值.方法:64例临床怀疑肺动脉栓塞的患者行CTPA检查,按随机表分为A、B两组:A组(n=32),自然呼吸状态下扫描,管电压100kV,螺距3.2,对比剂为碘海醇(350 mg I/mL)25 mL;B组(n=32),常规扫描模式,管电压120 kV,螺距2.2,对比剂为碘帕醇(370 mg I/mL).测量各级肺动脉CT值、标准差(SD)、上腔静脉CT值;计算肺动脉主干及双下肺动脉基底支信噪比(SNR)、对比噪声比(CNR);记录对比剂用量、容积CT剂量指数(CTDIvol)、剂量长度乘积(DLP)、有效辐射剂量(ED),并进行统计学分析.结果:两组肺动脉各级分支CT值及两下肺动脉基底支SD值、SNR差异均无统计学意义(P>0.05).A组肺动脉主干、左右肺动脉SD值高于B组,差异均有统计学意义(P<0.05);A、B两组肺动脉主干SNR、CNR及左右下肺动脉基底支CNR差异均有统计学意义(P<0.05).A组上腔静脉CT值[(469.93±196.22) HU]、对比剂用量(25.00mL)明显低于B组[(870.72±426.87)HU、(49.47±7.56)mL],差异有统计学意义(P<0.01);A组CTDIvol、DLP、ED较B组明显减低[(2.81±3.86) vs (5.65±1.14),P=0.000;(86.25±0.40) vs (163.63±39.00),P=0.000;(1.21±0.18)mSv vs (2.29±0.55)mSv,P=0.000],差异均有统计学意义(P<0.05).两组共检出肺动脉栓塞24例(A组11例,B组13例),两组间阳性显示率差异无统计学意义(P>0.05);两组上腔静脉线束硬化伪影显示率(A组9例,B组19例)差异有统计学意义(P<0.05).结论:自然呼吸状态下小对比剂用量CTPA检查图像质量可满足诊断要求,可减少上腔静脉线束硬化伪影,降低对比剂用量及辐射剂量.  相似文献   

8.
目的 探讨多层螺旋CT肺动脉成像(MSCTPA)中应用低管电压(kVp)结合个体化管电流设置减低辐射剂量的可行性.方法 连续56例拟行MSCTPA的患者纳入研究,用SPSS产生的随机数随机分为2组:A组27例,采用120 kVp和100 mAs;B组29例,采用100 kVp并根据患者体重个体化调节管电流输出(约1.0 mAs/kg),B组分别采用标准算法(FC13,B1组)和降噪算法(FC11,B2组)重建图像.比较辐射剂量及图像质量.结果 B组的容积CT剂量指数(CTDIvol)、剂量长度乘积(DLP)、有效吸收剂量(E)均数分别为5.1 mGy、83.3 mGy·cm和1.4 mSv,与A组比较,分别下降了64.3%、66.4%和66.7% (F =32.57,12.32,11.98,P<0.05).与A组比较,B1组图像噪声增加了118.2%(t=10.05,P<0.05),中央肺动脉和周围肺动脉的信噪比(SNR)与对比噪声比(CNR)及主观评分均值分别降低了51.5%、46.6%、50.8%、45.3%和20.4%(t=7.20、6.30、6.58、5.54、8.35,P<0.05).与B1组比较,B2组图像噪声又减低了32.5%(t=6.12,P<0.05),中央肺动脉和周围肺动脉的SNR与CNR及主观评分均值分别增加46.2%、46.2%、45.9%、46.9%和18.4%(t=3.19、3.55、2.95、3.37、5.42,P<0.05).与A组比较,B2组图像噪声增加47.3%(t=4.03,P<0.05),中央肺动脉和周围肺动脉的SNR与CNR及主观评分均值分别降低29.1%、21.8%、28.2%、19.6%和8.2%(=4.06、2.82、3.68、2.22、3.02,P<0.05).结论 在保证良好图像质量情况下,MSCTPA中应用低kVp(100 kV)结合个体化管电流输出设置(约1.0 mAs/kg)可以显著降低辐射剂量.  相似文献   

9.
目的 探讨低浓度对比剂联合低电压和迭代重建算法行320排CT冠状动脉成像的可行性.方法 选取心率≤70次/min、心律规则的60例患者,随机分为A、B2组,各30例,A组管电压120 kVp,370 mg I/mL对比剂,滤波反投影算法(FBP)重建;B组管电压100 kVp,270 mg I/mL对比剂,自适应迭代剂量减低算法(AIDR 3D)重建.采用双盲法评价2组间冠状动脉各节段图像质量的差异,比较2组兴趣区增强CT值、噪声(SD)、信噪比(SNR)、对比噪声比(CNR)、剂量长度乘积(DLP)和有效辐射剂量(ED)的差异.结果 60例检查成功率为100%.注射对比剂时患者有明显热感者B组(4/30)明显低于A组(25/30).主观评价2组间可诊断的节段差异无统计学意义(P>0.05).2组兴趣区增强CT值差异无统计学意义,但SD、SNR以及CNR均有显著差异(P<0.05).2组间DLP和ED差异有统计学意义(P<0.05),B组较A组降低约50%.结论 采用低浓度对比剂(270 mg I/mL)联合低电压(100 kVp)和迭代重建算法(AIDR 3D)在320排CT冠状动脉血管成像中能获得满意的诊断图像,且患者舒适度好,并能有效降低辐射剂量.  相似文献   

10.
目的:探讨低浓度等渗对比剂联合应用80 kV 和自适应统计迭代重建(ASiR)技术,对支气管动脉(BA)CT 血管成像(CTA)的价值。方法随机选取本院40例欲行 CT 增强检查的肺癌患者,18.5 kg/m2≤体质量指数(BMI)≤25 kg/m2。随机分为80 kV、260 mA 及120 kV、150 mA 2组,每组20例,其中80 kV 组为低浓度等渗对比剂(Visipaque 270 mg I/mL),50% ASiR;120 kV 组为高浓度对比剂(Ultravist 370 mg I/mL),滤波反投影(FBP)。比较2组中 BA 的 CT 值、图像噪声(SD)、信噪比(SNR)、对比噪声比(CNR)及有效辐射剂量(ED)。所得结果应用 SPSS 17.0软件采用独立样本 t 检验两两比较,P <0.05有统计学意义。结果80 kV 组的 CT 值(317.33 HU±70.44 HU)高于120 kV 组(256.39 HU±37.38 HU),差异有统计学意义(P <0.05);80 kV 组 SD、ED 及剂量长度乘积(DLP)[SD (7.55±1.51)HU;ED (1.74±0.14)mSv;DLP (124.94±9.9)mGy/cm]低于120 kV 组[SD (9.36±1.26)HU;ED (3.20±0.35)mSv;DLP (228.82±25.13)mGy/cm],差异有统计学意义(P<0.05);80 kV 组的 CNR 和 SNR(CNR 59.71±17.36;SNR 44.01±14.71)均优于120 kV 组(CNR 37.61±6.16;SNR 27.75±4.72),差异有统计学意义(P <0.05)。80 kV 组图像质量主观评分(3.73±0.66)略低于120 kV 组(3.81±0.59),但差异无统计学意义(t =-0.558,P >0.05)。结论对于 BMI 在正常范围内的患者,采用低浓度等渗对比剂联合80 kV 和 ASiR 技术行 BA CTA 检查,可在保证 BA 图像质量的同时显著降低有效辐射剂量47%,降低碘用量27%。  相似文献   

11.
Introduction Interventional Radiology has evolved into a specialty having enormous input into the care of the traumatized patient.In all hospitals,regardless of size,the Interventional Radiologist must consider their relationships with the trauma service in order to  相似文献   

12.
The ultrasonographic diagnosis of pneumothorax is based on the analysis of artifacts. It is possible to confirm or rule out pneumothorax by combining the following signs: lung sliding, the A and B lines, and the lung point. One fundamental advantage of lung ultrasonography is its easy access in any critical situation, especially in patients in the intensive care unit. For this reason, chest ultrasonography can be used as an alternative to plain-film X-rays and computed tomography in critical patients and in patients with normal plain films in whom pneumothorax is strongly suspected, as well as to evaluate the extent of the pneumothorax and monitor its evolution.  相似文献   

13.
KEY POINTS· Carbohydrate intake during exercise can delay the onset of fatigue and improve performance of prolonged exercise as well as exercise of shorter duration and greater intensity (e.g., continuous exercise lasting about 1h and intermittent high-intensity exercise), but the mechanisms by which performance is improved are different.  相似文献   

14.
目的 探讨磁共振扩散加权成像(DWI)和动态增强在颅底脊索瘤和侵袭性垂体瘤(IPA)鉴别诊断中的应用价值.方法 搜集经手术病理证实且影像学有鞍区破坏的颅底脊索瘤患者15例、向鼻咽部侵犯的IPA患者20例.测量二者的表观扩散系数(ADC)值,绘制受试者工作特征曲线(ROC),分析动态增强曲线的类型,统计达峰时间(TTP)、增强峰值(EP)和最大对比增强率(MCER),分析各个参数在鉴别诊断中的价值.结果 颅底脊索瘤的ADC值为(1.274±0.07)×10-3mm2/s,高于IPA ADC值(0.672±0.03) ×10-3 mm2/s(P <0.001),ADC阈值为0.964×10-3mm2/s时,ROC曲线下面积为0.997,敏感度为93.3%,特异度为100%.颅底脊索瘤时间-信号强度曲线(TIC)Ⅰ型14例,TICⅢ型1例,此例TICⅢ型者TTP约40 s;IPA TIC Ⅰ型7例,TICⅢ型13例.颅底脊索瘤和IPA的EP、MCER差异均有统计学意义(P <0.001).结论 ADC值和TIC的类型及其相关参数(EP,MCER)有助于颅底脊索瘤和IPA之间的鉴别.  相似文献   

15.
Primary hepatocellular carcinoma (HCC) continues to be one of the most common malignancies with an incidence of approximately one million cases per year and a dismal prognosis; some authors have reported a median survival of 1 ~ 2 months after diagnosis. Although surgery remains the only hope for cure, few patients are candidates[1,2].  相似文献   

16.
U50,488H对正常及缺氧心肌细胞L型钙电流的作用   总被引:3,自引:0,他引:3  
目的 探讨心脏阿片受体和β-受体相互作用的机制。方法 采用全细胞膜片钳技术,观察U50,488H(β-阿片受体选择性激动剂)对正常和缺氧心肌细胞L型钙电流的作用。结果 U50,488H剂量依赖性(0.1~100μmol/L)抑制正常心肌细胞的L型钙电流及异丙肾上腺素(0.1μmol/L)激动的钙电流,而细胞缺氧后,这一抑制作用减弱;U50,488H对Forskolin(10μmol/L)激动的L型钙电流无明显影响。结论 β-阿片受体对β-受体信号的负性调节作用在细胞缺氧后减弱,其作用位点可能发生于β-受体与腺苷酸环化酶环节之间。  相似文献   

17.
18.

Introduction

Overtraining is clearly a multifactorial disturbance. We aimed at evaluating the relative importance of overactivity and nutritional imbalances.

Methods

A comparison of 17 footballers with seven subjects with a diagnosis of overtraining evidenced that the two groups differ by energy expenditure resulting from physical activity (1573 ± 378.6 kcal/d from 804.7 ± 184.7 kcal/d) while food intake does not exhibit significant differences.

Conclusion

In this sample of subjects, inadequate food intake is found in both groups, so that overtraining appears rather characterized by a higher level of physical activity. Therefore, a relative energy deficit resulting from overactivity rather than dietary mistakes appears to explain the syndrome in these athletes, who are thus truly “overtrained”.  相似文献   

19.
Ultrasound is the first-line imaging study of the fetal brain performed at 12, 22 and 32 weeks of gestation. The very structured evaluation of biometric and morphological data, facilitated by the use of a checklist, ensures a high quality examination. All patients where an anomaly of any key element is suspected should be referred to a center dedicated to prenatal diagnosis for confirmation irrespective of the gestational age. Prenatal diagnosis plays a significant role in France since medical interruption of pregnancy until term is authorized.  相似文献   

20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号