首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 666 毫秒
1.
目的评价肺灌注/通气显像与螺旋CT肺动脉造影诊断肺栓塞各自的敏感性。方法以肺动脉造影为金标准,并按不同栓塞部位分为叶及段肺动脉、亚段肺动脉两组;按肺动脉狭窄程度分为严重狭窄(超过50%)和轻度狭窄(少于50%)两组。对40例疑肺栓塞患者先后行肺核素显像和螺旋CT肺动脉造影检查,根据分组分别比较两种方法的敏感性。结果①肺动脉造影共确定叶及段肺动脉栓塞102支。其中,肺灌注/通气显像显示86处叶及段性肺灌注/通气不匹配,敏感性为84.3%;螺旋CT肺动脉造影示98支,敏感性为96.1%;②肺动脉造影共确定140支亚段肺动脉栓塞,其中肺灌注/通气显示120处,敏感性为85.7%;螺旋CT肺动脉造影显示115支,敏感性为82.1%;③肺动脉狭窄程度>50%时,通气/灌注显示109处,螺旋CT肺动脉造影显示97支;肺动脉狭窄程度<50%时,通气/灌注显示91处,螺旋CT肺动脉造影显示121支。结论对叶及段肺动脉栓塞,两种方法敏感性基本相同;对亚段肺动脉栓塞,肺灌注/通气显像略高;肺血管轻度栓塞时,螺旋CT肺动脉造影略高。  相似文献   

2.
放射性核素肺显像与螺旋CT诊断急性肺栓塞的对比研究   总被引:3,自引:2,他引:1  
目的 比较肺通气/灌注(V/Q)显像与多层螺旋CT肺动脉造影(CTPA)在诊断急性肺动脉血栓栓塞症(PTE)方面的临床价值。方法 前瞻性分析2005年10月~2006年5月共51例临床疑诊急性PTE患者的肺灌注显像,其中18例行肺通气显像,并与CTPA对比。以汇总所有临床资料、各实验室检查及影像学检查后讨论得出的最终诊断作为“标准”。结果 最终24位患者被诊断为PTE占47.1%(24/51例),V/Q显像与CTPA的灵敏度分别为95.8%(23/24例)和95.8%(23/24例),特异性分别为88.9%(24/27例)和92.6%(25/27例),准确性分别为92.2%(47/51例)和94.1%(48/51例)。在定性诊断方面,2种影像学检查结果差异无统计学意义(χ^2=0.14,P=0.71),两者定性诊断符合率为86.3%(44/51例),Kappa值为0.73。24例PTE患者中,CTPA显示为“完全阻塞”的肺动脉血管所对应的44个肺段中,肺灌注显像显示为“放射性稀疏、缺损”的肺段数为32个(72.7%);CTPA显示为“部分充盈缺损”的肺动脉血管所对应的266个肺段中,肺灌注显像显示为“放射性稀疏、缺损”的肺段数为155个(58.3%),显示为“亚肺段放射性稀疏、缺损”的肺段数为9个(3.4%)。结论 V/Q显像与CTPA在PTE定性诊断方面符合率高,一致性好,但在定位方面存在差异;两者为互补关系。  相似文献   

3.
目的 通过与核素肺通气灌注显像比较,评价双能量CT肺血管成像(DE-CTPA)及双能量CT肺灌注成像(DE-CTLP)技术诊断肺栓塞的能力.方法 比较50例临床怀疑肺栓塞的患者DE-CTPA、DE-CTLP及核素肺通气灌注显像结果,以非线性相关检验比较DE-CTPA显示肺血管腔内充盈缺损与DE-CTLP显示灌注缺损之间的相关性,以核素为参考标准,应用一致性检验方法(Kappa检验)对照分析两者之间的一致性及DE-CTLP诊断肺栓塞的敏感性和特异性.结果 (1)50例临床怀疑肺栓塞患者中,4例CT图像质量差,不能评价.余46例共920个有效肺段中,DE-CTPA显示262个肺段肺血管腔内充盈缺损,DE-CTLP显示266个肺段明确灌注缺损.核素肺通气灌注扫描显示268个肺段灌注与通气不匹配.(2)DE-CTLP与DE-CTPA两者间显著相关(r=0.883,P<0.01);DE-CTLP与核素肺通气灌注显像的一致性良好(Kappa=0.940,P<0.01);以核素肺通气灌注成像为诊断参考标准,应用DE-CTLP诊断肺栓塞的阳性预测值95.5%(279/292),阴性预测值98.3%(641/652),敏感性96.2%(279/290),特异性98.0%(641/654).(3)应用CareDose 4D技术,DE-CTPA和DE-CTLP患者平均射线损伤剂量为(4.37±0.47)mSv.结论 应用DE-CTPA和DE-CTLP技术可以在一次扫描中同时获得常规CT肺血管成像的血管形态学信息和肺实质血流灌注情况,为临床诊断肺栓塞提供直观、有效的综合影像信息.  相似文献   

4.
肺灌注显像结合X线胸片诊断急性肺栓塞   总被引:3,自引:1,他引:2  
目的探讨肺灌注显像/x线胸片检查(Q/X)替代肺灌注/通气显像(Q/V)用于急性肺栓塞诊断的可行性。方法72例疑诊急性肺栓塞,且肺灌注显像显示至少有一个肺段灌注缺损的患者,24h内行x线胸片检查和肺通气显像,比较Q/X和QIV的诊断符合率和准确性。结果Q/x与Q/V结果的符合率为84.7%,Q/x对Q/V的阳性预测值为83.7%,阴性预测值为87.0%。在该组病例中,Q/X诊断急性肺栓塞的灵敏度为94.9%,特异性为63.6%,准确性为80.6%;而Q/V则分别为94.9%,78.8%和87.5%。5例慢性阻塞性肺部疾病(COPD)Q/X均显示不匹配,而Q/v均显示匹配,两者结果不同。结论对于多数疑诊急性肺栓塞患者,Q/X可以替代Q/v用于诊断,但对于COPD患者应选择Q/V。  相似文献   

5.
本文对11例经~(99)m锝大分子聚合白蛋白(~(99m)TC—MAA)肺灌注发现肺内有充盈缺损的患者作肺动脉造影(PA)研究。造影结果与肺核素显像基本一致。结合有关文献对肺动脉造影方法、成像特点及亚段肺栓塞(PTE)的血管造影诊断作了分析和探讨。  相似文献   

6.
实验性急性肺栓塞的比较影像学研究   总被引:6,自引:2,他引:4  
目的 探讨核素肺灌注显像、增强螺旋CT及数字减影肺动脉造影对猪急性肺栓塞实验模型 (相当于人类亚肺段水平肺栓塞 )的影像学特点。方法  13头中国实验用小型猪 ,经颈静脉注射明胶海绵栓子 (直径 3 8~ 4 2mm) ,制作肺栓塞模型后进行核素肺灌注显像、增强螺旋CT和数字减影肺动脉造影 ,以病理检查为标准 ,比较 3种检查方法的灵敏度和特异性。结果 对 195个肺段(动脉段 )进行分析 ,病理诊断阳性肺段 4 6个 ,阴性肺段 14 9个。核素肺灌注显像阳性肺段 5 1个 (包括假阳性肺段 11个 ) ,灵敏度为 87% ,特异性为 93% ;增强螺旋CT阳性肺段 4 4个 (包括假阳性肺段15个 ) ,灵敏度为 6 3% ,特异性为 90 % ;数字减影肺动脉造影阳性肺段 4 7个 (包括假阳性肺段 2个 ) ,灵敏度为 98% ,特异性为 99%。核素肺灌注显像病变检出率比增强螺旋CT高 (P <0 0 5 ) ,但与数字减影肺动脉造影相比差异无显著性 (P >0 0 5 )。增强螺旋CT可对栓子进行准确定位。结论 核素肺灌注显像对猪肺段 (相当于人类亚肺段 )肺栓塞的探测优于增强螺旋CT ,而后者对栓子定位优于前者 ;数字减影肺动脉造影对猪肺段肺栓塞诊断能力最强 ,但有创 ,应用受限。  相似文献   

7.
急性脑血栓性栓塞的核素显像诊断与疗效判断   总被引:5,自引:1,他引:4  
目的 评价核素显像对急性肺血栓性栓塞的诊断与疗效评价的价值。方法对10例临床确诊或可疑为肺栓塞的患者进行核素肺灌注、肺通气、肺血栓灶以及双下肢深静脉显像,4例与肺动脉造影或电子束CT结果对照。8例患者溶栓后复查肺灌注显像,2例患者昨查肺血栓灶显像,结果 肺灌注显像+下肢深静脉显像对急性肺栓塞诊断的阳性率为100%,与X线检查结果基本一致,溶栓后复查提示肺血流均有明显改善乃至恢复正常。结论 核素显像  相似文献   

8.
目的评价核素显像对急性肺血栓性栓塞的诊断与疗效评价的价值。方法对10例临床确诊或可疑为肺栓塞的患者进行核素肺灌注、肺通气、肺血栓灶以及双下肢深静脉显像,4例与肺动脉造影或电子束CT结果对照。8例患者溶栓后复查肺灌注显像,2例患者复查肺血栓灶显像。结果肺灌注显像+下肢深静脉显像对急性肺栓塞诊断的阳性率为100%,与X线检查结果基本一致,溶栓后复查提示肺血流均有明显改善乃至恢复正常。结论核素显像对诊断急性肺栓塞以及判断疗效是一种准确、可靠的无创性手段。  相似文献   

9.
肺灌注/通气显像与肺动脉造影诊断肺动脉栓塞的对比研究   总被引:10,自引:3,他引:7  
目的评价核素肺通气/灌注(V/Q)显像在肺动脉栓塞(PE)诊断中的价值。方法临床疑有PE患者30例,男女各15例,平均年龄(38.2±13.9)岁。均行胸部X线片检查、核素V/Q显像和肺动脉造影。11例患者在行肺灌注显像时,选择双侧足背静脉注射肺灌注显像剂,同时完成双下肢静脉显像。结果30例患者中22例V/Q显像示不相匹配的肺叶、肺段或多发亚肺段的放射性分布稀疏或缺损,提示为PE;但肺动脉造影证实22例中20例为PE。8例患者的V/Q显像为相匹配的肺叶、肺段或多发亚肺段的稀疏或缺损,提示不是PE,与肺动脉造影结果一致。核素V/Q显像诊断PE的灵敏度为100%(20/20例),特异性为80.0%(8/10例),准确性为93.3%(28/30例)。X线胸片和核素下肢静脉显像有助于PE的正确诊断。结论多数PE患者通过核素肺V/Q显像结合X线胸片可以作出明确诊断,少数肺V/Q显像与临床表现不符的患者需行肺动脉造影。  相似文献   

10.
增强MR肺灌注扫描诊断肺动脉栓塞的初步研究   总被引:3,自引:0,他引:3  
目的应用增强MR肺灌注扫描技术(MRPP)与增强MR肺动脉造影(MRPA)、核素肺灌注扫描相对照,初步探讨此项成像技术诊断肺动脉栓塞的敏感性及特异性。方法14例最终明确诊断为肺动脉栓塞患者,均行增强MRPA及MRPP。5例患者同时拥有核素肺通气一灌注扫描结果。3例经溶栓治疗后复查MRPA及MRPP。通过在上、中下肺野和异常区域内设置感兴趣区(ROI),测量信号强度(SI)、时间一信号曲线,获取灌注高峰期信号强度变化率。结果14例肺动脉栓塞患者,MRPA发现共62支肺动脉闭塞,MRPP共发现55个肺灌注异常区与之相吻合。符合率为88.71%,14例中MRPP显示有25个肺段合并有段及段以远的肺动脉栓塞。5例同时拥有核素扫描结果的患者,核素显示37个段灌注缺损,MRPP显示33个段,敏感度为89.19%,3例经溶栓治疗后复查MRPA和MRPP,均见受累肺动脉明显改善,肺灌注缺损区明显减少。正常灌注与灌注缺损区及低灌注区的信号强度变化率(TROS)差异有统计学意义(t=22.882,P〈0.01)。结论MRPP能够显示肺动脉栓塞的灌注缺损区和低灌注区。时间一信号曲线显示肺动脉栓塞区对比剂无灌注高峰期,信号曲线波动幅度小,信号强度变化率减低。MRPP对段及段以远的肺动脉栓塞的显示有较高的研究价值。MRPP联合MRPA可进一步提高MR诊断肺动脉栓塞的敏感度。  相似文献   

11.
三维增强磁共振肺动脉血管造影诊断急性肺栓塞的实验研究   总被引:13,自引:1,他引:12  
目的 探讨钆喷替酸葡甲胺(Gd-DTPA)三维增强共振肺动脉血管造影成像(3DCEMRPA)在急性肺栓塞(pulmonary embolism,PE)中的诊断价值。方法 对17只自体血栓引发的犬急性肺栓塞模型,利用3D快速扰相梯度回波序列(FSPGR)行3D CEMRPA检查和X线肺动脉血管造影(X-ray pulmonary angiography,XPA)检查,并与病理解剖对照。  相似文献   

12.
螺旋CT肺动脉造影对肺栓塞的诊断   总被引:10,自引:0,他引:10       下载免费PDF全文
目的:评价螺旋CT及其肺动脉造影诊断肺动脉栓塞(PE)的价值。方法:回顾性分析12例PE患,均行螺旋CT容积扫描,并在工作站进行图像后处理,获得肺动脉多平面重建图像及三维立体图像。结果:对12例196支肺动脉分支进行分析,受累率为46.4%;栓子发生在主肺动脉、左右肺动脉干及叶段肺动脉。多平面重建图像上表现为充盈对比剂血管内有充盈缺损区,或其远侧方无对比剂充填区。肺动脉成像示,主干血管内可见充盈缺损影,或呈截断状影;叶栓塞或段栓塞亦呈突然“截断状”,其远侧方肺动脉分支不显影或呈纤维状。结论:螺旋CT肺动脉造影不仅可以获得轴位图像,而且可以获得立体图像,可多轴向旋转观察PE部位,是诊断叶或段以上PE可靠而直观的检查方法。  相似文献   

13.
Our objective was to evaluate, in a routine clinical setting, the role of spiral CT as a second procedure in patients with clinically suspected pulmonary embolism (PE) and abnormal perfusion scan. We prospectively studied the role of spiral CT in 279 patients suspected of PE. All patients started their diagnostic algorithm with chest radiographs and perfusion scintigraphy. Depending on the results of perfusion scintigraphy, patients proceeded to subsequent levels in the algorithm: stop if perfusion scintigraphy was normal; CT and pulmonary angiography if subsegmental perfusion defects were seen; ventilation scintigraphy followed by CT when segmental perfusion defects were seen; and pulmonary angiography in this last group when results of ventilation/perfusion scintigraphy and CT were incongruent. Reference diagnosis was based on normal perfusion scintigraphy, high probability perfusion/ventilation scintigraphy in combination with abnormal CT, or pulmonary angiography. If PE was present, the largest involved branch was noted on pulmonary angiography, or on spiral CT scan in case of a high-probability ventilation/perfusion scan and a positive CT scan. A distinction was made between embolism in a segmental branch or larger, or subsegmental embolism. Two hundred seventy-nine patients had abnormal scintigraphy. In 27 patients spiral CT and/or pulmonary angiography were non-diagnostic and these were excluded for image analysis. Using spiral CT we correctly identified 117 of 135 patients with PE, and 106 of 117 patients without PE. Sensitivity and specificity was therefore 87 and 91%, respectively. Prevalence of PE was 53%. Positive and negative predictive values were, respectively, 91 and 86%. In the high-probability group, sensitivity and specificity increased to 97 and 100%, respectively, with a prevalence of 90%. In the non-high probability-group sensitivity and specificity decreased to 61 and 89%, respectively, with a prevalence of 25%. In a routine clinical setting single-detector spiral CT technology has limited value as a second diagnostic test because of low added value in patients with a high-probability lung scan and low sensitivity in patients with non-high-probability lung scan result.  相似文献   

14.
目的 探讨64层螺旋CT肺动脉造影(CT pulmonary angiography,CTPA)对肺动脉栓塞(pulmonary embolism,PE)的诊断价值.方法 回顾分析24例肺动脉栓塞患者的64层螺旋CT增强图像,将原始图像复制到EBW4.0工作站,对肺动脉主干及分支进行多平面重建(MPR),最大密度投影(MIP)及容积重建(VR)分析.结果 24例患者中,共检出了76处肺动脉及其分支的栓子.其中,左、右肺动脉主干14处(右主干10处、左主干4处),肺叶动脉24处,肺段动脉26处,亚肺段动脉12处.CT表现为肺动脉主干或分支内混合性、附壁性、中心性充盈缺损,可分为完全性或部分性.结论 64层CTPA具有准确、高效、无创等优点,可直观、立体地观察到肺动脉血栓的大小、分布、范围及类型,是临床诊断及观察疗效的首选方法,有望成为肺动脉栓塞检查的“金标准”.  相似文献   

15.
目的:探索双源 CT 后处理软件在外周型肺栓塞诊断中的价值。方法对150例可疑肺栓塞患者进行扫描,20例患者符合标准。扫描数据采用肺栓塞分析软件(PED)、双能量肺灌注成像(DEPI)及肺动脉成像(CTPA)对图像重建,分别由2名高年资血管专业诊断医师对 PED 图、DEPI 图及 CTPA 图进行分析,根据诊断标准,分别记录由 PED 图、CTPA 图诊断的肺段及亚段动脉肺栓子位置、数目,计算显示率并评价其统计学差异;同时评价 PED 图与 DEPI 图对肺段动脉肺栓塞诊断一致性。结果 CTPA图共发现30处段动脉及40处亚段动脉内存在血栓,其检出率为7.50%及5.00%,PED 图共发现48处段动脉及62处亚段动脉内存在血栓,其检出率为12.00%及7.75%,CTPA 图与 PED 图存在显著的统计学差异(χ2=4.60、5.06,P <0.05)。以 PED 图诊断结果为参考标准,Kappa 系数=0.94,一致性极好。在 PED 图发现48处段动脉肺栓塞中,13处完全性栓塞,DEPI 图显示10例出现灌注缺损,3例出现灌注稀疏;35处不完全性肺栓塞,2例灌注缺损,29例出现灌注稀疏,4例无明显灌注改变。结论双源 CT肺栓塞探测软件联合能量灌注成像能够明显提高外周型肺栓塞的诊断率,具有较高的实用性及临床价值。  相似文献   

16.
双源CT双能量肺灌注成像诊断急性肺栓塞的实验研究   总被引:5,自引:0,他引:5  
目的 评价双源CT(DSCT)双能量肺灌注成像(DEPI)的可行件及其诊断急性实验性肺栓塞的价值.方法 对8只新两兰白兔制备成急性肺栓塞模型的前、后行DSCT平妇及双能量增强扣描,并进行数据后处理,分别得到CT解剖图像(CTPA)、DEPI及两者融合图像,观察肺动脉内有无栓子,分析栓塞前、后的肺灌注影像表现;进行家兔肺大体病理解剖和镜下观察.计算CTPA、DEPI及融合图像的诊断敏感度、特异度、阳性预测值(PPV)、阴性预测值(NPV).应用Kappa系数评价两种检查结果的一致性.结果 7只兔模型制作成功,1只因肺内导管头影响图像评价而排除;6只兔30个肺时数据可用于分析.病理共发现18个肺叶栓塞阳件,12个阴性.与正常肺组织相比,肺柃塞区域DEPI表现为灌注不良或缺损,CTPA表现为相应肺动脉中断或充盈缺损.CTPA诊断的敏感度、特异度、PPV、NPV分别为66.7%(12/18)、100.0%(12/12)、100.0%(12/12)、66.7%(12/18),与病理结果吻合度一般(Kappa=0.651);DEPI诊断的敏感度、特异度、PPV、NPV分别为88.9%(16/18)、91.7%(11/12)、94.1%(16/17)、84.6%(11/13),与病理结果吻合度较强(Kappa=0.795).融合图像结果与DEPI一致.结论 DSCT的DEPI能够反映兔肺部『『fL流分布情况,对肺栓塞的诊断有较高的敏感度,并与病理结果有较强的一致性.  相似文献   

17.
PURPOSE: Development of a comprehensive magnetic resonance (MR) examination consisting of MR angiography (MRA) and MR ventilation and perfusion (MR V/Q) scan for the detection of pulmonary emboli (PE) and assessment of the technique in a rabbit model. MATERIALS AND METHODS: Reversible PE was induced by inflating a non-detachable silicon balloon in the left pulmonary artery of five New Zealand White rabbits. MR V/Q scans were obtained prior to, during, and after balloon deflation. MRA was performed during balloon inflation. MR ventilation imaging was performed after the inhalation of hyperpolarized helium-3. MR perfusion imaging was performed with Flow-sensitive Alternating Inversion Recovery with an Extra Radiofrequency pulse technique (FAIRER). High-resolution contrast-enhanced MR pulmonary angiography was used to confirm the occlusion of the pulmonary artery. All imaging was performed on a 1.5-T whole body scanner with broadband capabilities. RESULTS: High-resolution ventilation images of the lungs were obtained. No ventilation defects were detected before, during, or after resolution of simulated PE. FAIRER imaging allowed visualization of pulmonary perfusion. No perfusion defects were detected prior to balloon inflation. During balloon inflation (PE), there was decreased perfusion in the left lower lobe. After reversal of the PE, there was improved perfusion to the left lower lobe. In analogy to nuclear medicine techniques, acute PE produced a mismatched defect in the MR V/Q scan. MRA verified the occlusive filling defect in the left pulmonary artery. CONCLUSION: High-resolution MRA and MR V/Q imaging of the lung is feasible and allows comprehensive assessment of pulmonary embolism in one imaging session.  相似文献   

18.
目的:评价螺旋CT在诊断肺动脉栓塞中的作用。方法:16例肺动脉栓塞患者行螺旋CT肺动脉造影 (SCTA)检查,层厚3mm,扫描时间0.8s,对比剂注射速度3.5ml/s,总量100ml,扫描延迟时间15s。结果:16例 共644支,其中134支肺动脉及分支显示了栓塞,占20.8%。228支肺段肺动脉中,有56支显示肺动脉栓塞,占分 析肺动脉支的24.5%。204支亚段肺动脉中37支显示肺动脉栓塞,占分析肺动脉支15.4%。肺动脉栓塞的CT形 态:①直接征象为不同程度的肺动脉分支内充盈缺损。中心型充盈缺损17支,偏心型充盈缺损44支,附壁血栓型 34支,完全阻塞型39支。②间接征象胸膜下肺梗死灶,内乳动脉一侧增粗,肺纹理稀少,胸水,肺动脉高压。结论: 螺旋CT肺动脉造影是诊断肺动脉栓塞的快速、有效、无创伤的诊断方法。  相似文献   

19.
目的:探讨双源CT双能量肺灌注成像对肺动脉栓塞的诊断和临床应用价值。方法:对疑诊肺动脉栓塞的78名患者行双源CT肺动脉成像双能量扫描,数据经后处理得到肺动脉血管图像(CTA)和肺灌注图像(PBV)。两位医师对PBV图像进行质量评价和分型,同时观察CTA图像有无栓塞以及栓塞的部位、程度。分析PBV图像的表现与CTA图像、肺部异常改变的关系。用Kappa系数检验两位观察者对PBV图像质量评价和分型的一致性,计算PBV图像诊断肺栓塞的敏感度、特异度、阳性预测值和阴性预测值。结果:两位医师对肺灌注图像质量的分级以及肺灌注图像的分型一致性极强,K值分别为0.87、0.80,P值均<0.01。PBV图像诊断肺栓塞的敏感度为95.30%,特异度为56.40%,阳性预测值为70.70%,阴性预测值为91.20%。对于完全栓塞的患者,其敏感度和特异度均为100%。结论:双源CT双能量肺灌注成像能够显示肺动脉栓塞导致肺血流改变的肺灌注异常。  相似文献   