首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 433 毫秒
1.
内听道及内耳结构的正常MRI表现   总被引:3,自引:0,他引:3  
目的:探讨正常内听道及内耳解剖结构的正常MRI表现.材料和方法:选择40例(80耳)无耳部病变患者,使用GE 1.5T超导型MR成像仪,头部环形线圈或颞下颌线圈FSE序列薄层扫描,用最大强度投影术(MIP)对兴趣区进行多轴位重建,多视角多平面旋转观察内听道及内耳膜迷路结构.结果:全部病例均能满意显示两侧内听道及内耳膜迷路结构,半规管、椭圆囊、球囊、耳蜗管及内听道呈高信号,面听神经呈低信号,半规管直径约1.17~1.40mm,耳蜗高度4.7~4.8mm,蜗底直径7.00~7.5mm,内听道宽度5.5mm左右,面神经、前庭上神经、耳蜗神经、前庭下神经截面直径约0.61~1.1mm.结论:MR水成像技术能立体直观的显示内听道及内耳膜迷路的细微结构,是一个值得重视的成像方法.  相似文献   

2.
3D-CISS序列与3D-TSE序列对Ⅶ~Ⅸ对颅神经成像质量的比较   总被引:4,自引:0,他引:4  
目的:通过3D-CISS序列与3D-TSE序列对Ⅶ~Ⅸ对颅神经成像质量的比较,确定3D-CISS序列对脑脊液包绕的Ⅶ~Ⅸ对颅神经和淋巴液充盈的内耳迷路成像显示的优势。方法:应用3D-CISS序列与3D-TSE序列分别对第Ⅶ~Ⅸ对颅神经及内耳迷路进行MR成像,在MPR图像及MIP重建图像上最大程度的显示颅神经及内耳迷路,并对两种序列的成像质量进行统计比较。结果:面神经的脑池段、内听道近段及远段、前庭蜗神经的脑池段及内听道近段、耳蜗、前庭及半规管在两个序列中全部以100%的几率显示;蜗神经、前庭上神经、前庭下神经及舌咽神经在3D-CISS序列、3D-TSE序列的显示几率依次分别为:100%、81.2%;100%、51.4%;100%、42.0%;100%、57.1%;面神经、前庭蜗神经的内听道段、内耳迷路、舌咽神经的3D-CISS序列成像质量明显优于3D-TSE序列成像;面神经、前庭蜗神经的脑池段3D-CISS序列成像质量略优于3D-TSE序列。结论:对于被脑脊液包绕的颅神经和淋巴液充盈的内耳迷路的成像,3D-CISS序列是最佳的选择。  相似文献   

3.
儿童先天性感音神经性耳聋的高分辨率CT和MRI研究   总被引:3,自引:0,他引:3  
目的 探讨CT和MRI在儿童先天性感音神经性耳聋中的应用价值.资料与方法 对48例儿童先天性感音神经性耳聋患者进行颞骨高分辨率CT和MRI检查.结果 前庭导水管扩大11例,MRI显示所有病例内淋巴管和内淋巴囊均扩大;单纯Mondini Ⅱ型畸形2例;水平半规管不发育2例;共同腔畸形合并内听道狭窄1例;脑脊液内耳漏2例,MRI显示前庭耳蜗神经畸形;单侧Mondini Ⅰ型畸形合并单侧内听道狭窄1例;双侧内听道狭窄合并前庭半规管发育不良1例;单纯内听道狭窄1例.所有内听道狭窄者MRI均显示其前庭耳蜗神经畸形.其余27例CT和MRI均未见内耳及内听道畸形.结论 颞骨高分辨率CT能显示内耳骨迷路畸形,MRI则能显示畸形的迷路内腔,同时还清晰显示扩大的内淋巴管和内淋巴囊以及内听道内前庭耳蜗神经.因此MRI在评价先天性感音神经性耳聋方面比CT更具优越性.  相似文献   

4.
目的:对比研究FLAIR序列与T2加权序列在颅脑占位病变中的诊断敏感性,方法:对64例颅脑占位病变患者行快速FLAIR及T2加权序列MR扫描,比较FLAIR序列及T2加权序列显示脑占位病变的差异。结果:(1)64例脑占位病变中,FLAIR显示病灶124个,T2加权像显示109个,FLAIR与T2加权像在显示病灶数目上无统计学差异(P>0.05);(2)12例脑转移瘤患者,FLAIR共显示病灶72个,T2加权像权显示57个,FLAIR较T2加权像显示病灶数目敏感(P<0.05);(3)109个病灶的边界,水肿及内部结构在FLAIR均较T2加权像显示清晰(P<0.01)。结论:FLAIR像在检出转移性肿瘤的病灶数目及显示脑占位病变的病灶边界、范围及内部结构均优于T2加权像,可作为常规颅脑检查的补充序列。  相似文献   

5.
正常人内耳前庭、半规管及耳蜗的MRI测量   总被引:27,自引:0,他引:27  
目的 利用高级快速自旋回波 (FASE)重T2 WI三维重建技术重建正常内耳膜迷路 ,建立内耳系统各主要结构的MRI测量正常值。方法 将 5 3例健康志愿者按年龄分为婴幼儿组、少年组、青年组、中年组和老年组 ,共 10 6只内耳分别行三维 ( 3D)FASE重T2 WI横断扫描。原始图像行最大强度投影 (MIP)重建 ,多角度旋转并测量内耳各主要结构的径线 ( 3个半规管高度和管径 ,耳蜗蜗高、底周直径和管径 ,前庭垂直径 ) ;行透视容积成像 (PVR)重建测量内耳液体容积。各观察指标就侧别、性别和年龄组间进行比较。结果  ( 1) 3DFASE重T2 WI可清晰显示正常膜迷路结构和内听道内的神经 ;( 2 )内耳液体容积无年龄组间、侧别间差异 ,但男性 ( 0 2 42± 0 0 2 3 6)mm3与女性 ( 0 2 2 6±0 0 2 1)mm3间差异有非常显著性意义 (P <0 0 0 1)。 3个半规管高度、前庭垂直径无年龄组间、侧别间差异 ,但上半规管高度男性 ( 5 5 11± 0 62 6)mm与女性 ( 5 167± 0 3 5 7)mm间差异有非常显著性意义(P <0 0 0 1) ;水平半规管高度男性 ( 3 763± 0 495 )mm与女性 ( 3 44 6± 0 40 5 )mm间差异有非常显著性意义 (P <0 0 0 1) ;后半规管高度男性 ( 5 2 2 7± 0 5 47)mm与女性 ( 4 786± 0 5 0 0 )mm间差异有非常显著性意义 (  相似文献   

6.
MR涎管造影临床研究及应用   总被引:8,自引:1,他引:7  
目的 评价MR涎管造影的各种序列技术和临床应用。方法 依次采用短时反转恢复序列(STIR)、重T2加权快速自旋回波序列(重T2WIFSE)、单次激发快速自旋回波序列(SSFSE),厚层扫描,快速采集,于服用维生素C(VitC)前后分别扫描。检查了30例,其中13例为志愿者,17例为可疑涎管异常者。结果 3种序列均能显示正常腮腺和颌下腺主导管。13例志愿者STIR序列均能清晰显示涎管1级和2级分支,2例能显示管径约为0.8mm的末梢分支;重T2WIFSE序列可清晰显示13例志愿者1级分支、10例2级分支;SSFSE序列可显示10例涎管1级分支、6例2级分支。STIR序列能清晰显示患者主导管和涎管1、2级分支;重T2WIFSE序列清晰显示患者12例涎管1级、8例2级分支;SSFSE序列清晰显示患者10例1级分支、4例2级分支。17例可疑异常者,腺体炎症7例,急性炎症主导管稍增粗,末梢导管呈点、球状扩张;颌下腺癌1例,导管受压移位,呈截断状改变;良性肿瘤7例,涎管受压移位,无中断;干燥综合征及涎腺病各1例,涎管未见明显异常。16例患者含服VitC0.2g后5min重复扫描,涎管显示较前增粗。结论 MR涎管造影能清晰显示腮腺和颌下腺导管系统,其中STIR序列能清晰显示导管2级分支,是1种显示涎管的非侵袭性方法,含服VitC后可使唾液分泌增多,从而使涎管显示率增加,具有较高的临床实用价值。  相似文献   

7.
目的;比较八次激发SE-EPI与呼吸门控FSE及SSFSE T2WI在肝脏的应用。方法:对14例志愿者及21例肝病患者行上腹部呼吸门控FSE及SSFSE和屏气八次激发SE-EPI扫描。所有T2WI序列均运用脂肪抑制技术。定量分析肝脏、病灶的信噪比及肝脏-病灶的对比噪声比,评价各序列的图像质量及伪影。结果:八次激发SE-EPI与SSFSE及FSE在肝脏及病灶信噪比,肝脏-病灶对比度噪声比和图像质量方面无明显差异(P>0.05)。其磁敏感伪影较FSE及SSFSE重(P<0.01),SE-EPI化学位移伪影与SSFSE及FSE相比无明显差别(P>0.05)。SE-EPI及FSE运动伪影明显比SSFSE重(P<0.01),但SE-EPI运动伪影与FSE相比无明显差别(P>0.05)。SE-EPI与FSE及SSFSE的图像质量无明显差别(P>0.05)。结论:八次激发SE-EPI能够在较短时间里提供较高质量的上腹部T2WI。被检查者在扫描时可自由平静呼吸或屏气,可作为肝脏T2WI的补充序列。  相似文献   

8.
目的:探讨3D-FIESTA序列内耳及内听道成像技术及其临床应用价值.方法:用GE signa 3.0T超导型磁共振对25例共50耳应用3D-FIESTA序列做颞骨三维容积扫描,采用多平面重组(MPR)、最大强度投影(MIP)及仿真内窥镜(VE)行后处理,观察3D-FIESTA序列对内耳及内听道内各解剖结构的显示.结果:3D-FIESTA序列扫描结合MPR、MIP和VE重组对内耳迷路及内听道内神经及血管显示清晰,能够清晰显示两者之间的关系,MPR和VE重组对神经的显示优于MIP重组,MIP对半规管显示与双斜面MPR并无明显差别,VE和斜矢状面对于内听道内各神经孔的位置关系具有重要意义.结论:3D-FIESTA序列对内耳及内听道的结构显示清晰,具有较高的临床应用价值.  相似文献   

9.
低场磁共振FLAIR序列对脑部疾病的诊断价值   总被引:1,自引:0,他引:1  
目的探讨低场磁共振FLAIR序列对脑部病变的诊断准确性,并与常规T2WI序列比较。方法120例经手术病理或临床证实的脑部病变患者均经低场磁共振FLAIR序列与常规T2WI序列检查,对获自两种技术的病灶检出率及病灶内部结构与边缘的显示程度进行了比较。结果在120例的262个脑部病变中,FLAIR序列的检出率为98.5%(258/262),而常规T2WI序列为82.4%(216/262);FLAIR序列良好显示病灶内部结构与边缘比例为66.3%(171/258),而常规T2WI序列仅为13.4%(29/216),二者有显著性差异(P〈0.01)。结论在低场MRI中,FLAIR序列显示脑皮层、皮层下和脑室旁病灶的敏感性明显高于常规T2WI序列,且能获得更多的病理信息。  相似文献   

10.
目的:探讨内听道底神经和神经孔道的正常CT和MRI解剖特点并进行定量研究。方法:选择健康成年人60例共120耳,60耳行颞骨CT扫描,60耳行内耳FIESTA序列MRI检查,在多平面重组(MPR)图像上对内听道底的神经和神经孔道进行测量。结果:内听道底前后径(4.07±0.97)mm,上下径(3.24±0.88)mm;面神经管迷路段长度(3.04±0.52)mm,宽度(0.96±0.31)mm;前庭上神经管长度(2.52±0.48)mm,宽度(0.83±0.30)mm;前庭下神经管长度(1.07±0.23)mm,宽度(0.73±0.21)mm;蜗神经管长度(0.89±0.19)mm,宽度(2.05±0.39)mm;单孔长度(3.56±0.68)mm,宽度(0.56±0.11)mm。面神经直径(1.00±0.03)mm;前庭上神经直径(0.98±0.04)mm;前庭下神经直径(0.71±0.03)mm;蜗神经直径(1.03±0.04)mm;后壶腹神经直径(0.47±0.02)mm。结论:CT和MRI能够准确清晰地显示内听道底的正常解剖结构并可进行准确测量,为临床和影像学检查提供诊断依据。  相似文献   

11.
膝关节软骨缺损性病变的MR成像序列研究   总被引:17,自引:1,他引:16  
目的 评价各种临床常用MR扫描序列诊断关节软骨病变的价值。方法 实验猪膝关节 5只 ,在股骨内外髁关节面软骨上制成缺损模型 ,分别采用各种常用序列扫描 ,测量各种扫描序列上关节软骨的信噪比 (SNR)、软骨相对周围组织的对比噪声比 (CNR) ,采用一致性评价指标 (ICC)评价软骨缺损MRI测量值与实际测量值的一致性。采用实验中优选的MR序列对 2 3例膝关节病变患者进行检查 ,并与关节镜分级诊断结果比较。结果 实验膝关节软骨SNR良好者有质子和T2 WI快速自旋双回波 (FSEPD/T2 WI)、附加脂肪抑制的三维快速扰相梯度回波 (FS 3DFSPGR)和附加脂肪抑制的质子和T2 WI快速自旋双回波 (FSFSEPD/T2 WI)。CNR表现“极佳”者 ,对骨皮质 :FS 3DFSPGR、FSFSEPD/T2 WI;对关节液 :脂肪抑制快速自旋回波 (FSFSE)T2 WI、FS 3DFSPGR ;对半月板和韧带 :FS 3DFSPGR、FSFSEPD/T2 WI、SET1WI、反转时间为 70 0ms的T1WI反转恢复 (IRTI70 0 )序列 ;对脂肪 :FS 3DFSPGR、SET1WI。ICC只有IRTI70 0序列有统计学上的意义 (P <0 .0 5 ) ,且一致性评价为“极佳”。对2 3例膝关节病变患者MR检查结果 :FS 3DFSPGR序列的敏感性为 86 %、特异性为 96 %、表示准确度的Kappa值为 0 .8;IRTI70 0序列的敏感性为 6 8%、特异性为 99%、Kappa值为 0  相似文献   

12.
PURPOSE: To evaluate whether multiphase-multisection T2-weighted magnetic resonance (MR) images help exclude pseudolesions mimicking leiomyoma and adenomyosis on static T2-weighted fast spin-echo (FSE) MR images and to characterize temporal changes in uterine signal intensity related to uterine contraction. MATERIALS AND METHODS: T2-weighted FSE and multiphase-multisection single-shot FSE (SSFSE) MR imaging were performed in 43 patients who underwent hysterectomy. Each imaging set was evaluated separately by two independent readers, and receiver operating characteristic analysis was performed. In the 43 patients and in 49 other patients suspected of having pelvic abnormality, a combination of signal intensity changes on FSE and SSFSE MR images was classified into five patterns, and temporal low-signal-intensity changes on SSFSE MR images were characterized. RESULTS: For detection of leiomyoma on FSE and SSFSE MR images, the respective values of the area under the receiver operating characteristic curve were 0.98 and 0.97 for reader 1 and 0.96 and 0.96 for reader 2; for detection of adenomyosis on FSE and SSFSE MR images, the respective values were 0.82 and 0.84 for reader 1 and 0.80 and 0.89 for reader 2 (P >.05). SSFSE MR images helped exclude pseudolesions in 1%-3% cases of leiomyoma and in 3%-4% cases of adenomyosis. Temporal signal intensity changes were observed in 53% of 368 segments. The most frequent shape of temporal low signal intensity was diffuse followed by ill-defined focal type. Characteristic shape of temporal low signal intensities was band- or sticklike, which was observed in as many as 19% of 368 segments. CONCLUSION: Multiphase-multisection T2-weighted SSFSE MR images do not improve accuracy in detection of leiomyoma and adenomyosis compared with FSE MR images; however, they helped characterize features of temporal low signal intensities in the uterus, which are related to uterine contractions.  相似文献   

13.
目的:比较MRI各序列诊断创伤性脑损伤(traumatic brain injury,TBI)的价值.方法:对260例TBI患者行MRI序列组合扫描,包括FLASH、FLAIR、SE T1WI、TSE T2WI,分析不同类型TBI的影像特点,比较各序列对病灶的显示率.结果:260例中,FLASH显示244例(93.8%),FLAIR显示249例(95.8%),T2WI显示200例(76.9%),T1WI显示199例(76.5%),FLASH与FLAIR比较、T2WI与T1 WI比较,显示率差异均无统计学意义(P均>0.05);FLASH、FLAIR分别与T2WI、T1WI相比,显示率差异均有统计学意义(P均<0.01),FLASH、FLAIR对TBI病变的显示优于T2WI、T1WI.结论:MRI各序列显示TBI病灶总体敏感性由高至低依次为FLAIR、FLASH、T2WI、T1WI.FLAIR、FLASH应作为MRI诊断TBI的首选序列.  相似文献   

14.
磁共振磁敏感成像技术在脑部血管畸形中的应用优势   总被引:1,自引:0,他引:1  
目的探讨MRI磁敏感成像(SWI)技术在脑部血管畸形中的应用价值。方法对31例疑有脑部血管畸形的患者,应用MRI自旋回波T1WI、T2WI序列、SWI技术进行平扫,最小信号强度投影(MinIP)法图像重建。其中另有11例动静脉畸形和4例烟雾病者同时行MRA检查。结果31例患者均获得了清晰的畸形血管图像,其中海绵状血管瘤15例,动静脉畸形11例,烟雾病4例,静脉瘤1例。结论磁共振SWI技术的应用,大大提高了对脑部血管畸形疾病的诊断的准确性,对手术治疗有极大的指导作用。  相似文献   

15.
目的探讨MRI对腮腺腺淋巴瘤的表现特征的显示。资料与方法回顾性分析17例经病理证实的腮腺腺淋巴瘤的影像资料。结果 (1)17例腮腺腺淋巴瘤患者中男16例,女1例,50岁以上者13例。9例病灶单发,8例多发,共32个病灶,病灶中心位于腮腺后下象限者18个(56.25%),形态呈类圆形28个(87.5%),分叶4个(12.5%),边缘清楚31个(96.88%),边缘模糊1个。(2)和肌肉相比,病灶在快速自旋回波(FSE)T1WI显示为等、稍高、高信号的数目分别占5/32个(15.625%),25/32个(78.125%),2/32个(6.25%);FSE T2WI及T2WI脂肪抑制序列呈中等高信号,数目分别为17/32个,15/32个;2/32个,30/32个;FSE T1WI信号均匀31/32个,FSET2WI及T2WI脂肪抑制序列信号不均匀者32/32个,小囊变区18/32个(56.25%),32个病灶均显示低信号包膜;(3)增强轻度强化比率31.25%,中度强化31.25%,明显强化37.5%;(4)17例中,误诊为混合瘤4例,2例笼统诊断为良性肿瘤,余11例均正确诊断为腺淋巴瘤。结论中年以上的男性,MRI发现腮腺浅叶的后下象限具有良性肿瘤病灶特征,平扫各序列显示有低信号包膜,在FSE T1WI,FSE T2WI及FSE T2WI脂肪抑制序列信号特征多为稍高/中等高/高信号。采用FSE T2WI脂肪抑制序列观察到内部有小囊变区,强化多为中等或明显强化,且病灶多发时,诊断时应首先考虑腺淋巴瘤可能。  相似文献   

16.
目的 比较IDEAL T2WI、FSE T2WI序列在脊柱脂肪抑制扫描中的应用价值.资料与方法 35例脊柱MRI检查患者(颈椎10例、胸椎8例、腰椎17例)同时采用IDEAL T2WI、FSE T2WI两种脂肪抑制序列扫描,对图像脂肪抑制质量进行主观评价分级评估并测量信噪比.结果 FSE T2WI脂肪抑制质量主观评价分级为颈椎( 1.30±0.48)级、胸椎(1.80±0.71)级、腰椎(2.30±0.69)级,而IDEAL T2WI序列颈、胸椎均为(3.00±0.00)级、腰椎为(2.80±0.56)级;FSE T2WI脂肪抑制序列信噪比平均值分别为颈( 8.73±4.66)、胸(11.33±9.27)、腰(6.81±10.15),IDEAL T2WI序列信噪比平均值分别为颈( 18.90±7.71)、胸(26.02±11.61)、腰(19.57±9.12),两序列信噪比差异有统计学意义(t=3.73、5.72、11.23,P<0.05).结论 脊柱MRI脂肪抑制扫描IDEAL T2WI序列优于FSE T2WI序列,IDEAL T2WI序列能提供更均匀稳定的脂肪抑制效果,脊柱图像信噪比高,可清晰显示脊柱病变.  相似文献   

17.
目的探讨眼眶磁共振扫描成像技术。方法采用GE1.5TsignaEchospeed或GE1.5TsignaTwinspeed,对30例患者做眼眶磁共振成像(MagneticResonanceImaging)。脉冲序列:SET1加权(weightedImagingWI),FSET2加权(weightedImagingWI),T2WI采用脂肪抑制技术或SET1flair,FRFSET2WIT2WI采用脂肪抑制技术。扫描方位:横轴位(Axial)、冠状位(Coronal)、矢状斜位(ObliqueSagittal)和横轴俯卧位(prone)等。扫描参数:Fov18cm×18cm,SET1WI:TR440msTE11ms,FSET2WI:TR3000msTE98ms或T1flair:TR2143ms,TE11ms,TI750ms,FRFSET2WI:TR3500msTE80ms,矩阵256×256,接收带宽15.63MHz,平均激励次数4次,层厚3~4mm,无间隔。增强对比剂用GdDTPA0.1mmolkg。结果横轴位可清晰显示视神经全长及眼内外直肌及与病变的关系。冠状位在同一层面可清晰显示视神经、眼内外直肌、眼上下直肌的断面及与病变的关系。矢状斜位可清晰显示视神经全长、眼上下直肌及与病变的关系。结论磁共振扫描参数的优化组合和选择正确的扫描方位,及T2WI脂肪抑制技术等的应用更有助于显示正常眼眶解剖结构及眼眶病变的定位和诊断。  相似文献   

18.
The aim of the present study was to assess the performance of pre-biopsy T2-weighted MR imaging using multishot echo-planar imaging (EPI) sequence for visualization of prostate cancer and to compare image quality with that of fast spin-echo (FSE) sequence. Thirty-nine patients with suspected prostate cancer and one healthy male volunteer were examined on a 1.5-T MR scanner equipped with a pelvic phased-array coil. Axial MR images were obtained using multishot EPI sequence with a multishot number of 16 and FSE sequence without fat suppression. Paired EPI and FSE images were independently evaluated by three radiologists. Furthermore, signal-to-noise ratio (SNR) and contrast-to-noise ratio (CNR) were compared between EPI and FSE images of 12 pathologically proven lesions of prostate cancer. Delineation of the periprostatic venous plexus, prostate zonal anatomy, and seminal vesicle on EPI was graded to be superior/inferior to FSE in 15.8/0, 14.6/0, and 21.5/4.3% of cases, respectively. On the other hand, delineation of the neurovascular bundle was superior/inferior to FSE in 2.6/13.2% of cases. The SNR and CNR of prostate cancer on EPI were significantly higher than those on FSE (7.99±2.51 vs 3.36±0.58, p<0.0001, and 5.51±2.02 vs 2.21±0.79, p<0.0001, respectively). In conclusion, multishot EPI has higher quality of contrast resolution for imaging of prostate cancer compared with FSE and would have the potential usefulness in the detection of prostate cancer, although these results obtained with a phased-array coil cannot be extrapolated to examinations performed with an endorectal coil.  相似文献   

19.
目的 探讨3.0T高分辨MRI对兔腹主动脉粥样硬化模型药物诱发斑块破裂和血栓形成的成像研究.方法 20只雄性新西兰白兔,采用数字表法随机分为实验组16只,对照组4只,采用间断高脂饲料喂养结合球囊拉伤腹主动脉技术建立动脉粥样硬化模型,并在建模3个月后给予蝰蛇毒+组胺药物诱发试验,以期斑块破裂和形成血栓.在药物诱发试验前后...  相似文献   

20.
PURPOSE: To evaluate the accuracy of T2-weighted (T2WI) with diffusion-weighted imaging (DWI) as compared with T2WI alone for predicting seminal vesicle invasion (SVI) of prostate cancer. MATERIALS AND METHODS: A total of 30 patients with SVI and 136 patients without SVI who underwent prostate MR imaging were included in the study. MR images were analyzed retrospectively and independently by two readers for SVI on T2WI and T2WI with DWI using a 5-point scale. RESULTS: For predicting SVI, the specificity for T2WI with DWI and for T2WI was 97% and 87%, respectively, and accuracy was 96% and 87%, respectively, as determined by the experienced reader (P < 0.01). For the less experienced reader, the specificity for T2WI with DWI and for T2WI was 96% and 81%, respectively, and accuracy was 90% and 77%, respectively (P < 0.01). The diagnostic performance of the less experienced reader with T2WI with DWI led to significant improvement of the area under the receiver operating characteristic curve (Az) as compared with T2WI alone (Az = 0.815 versus 0.696; P < 0.01). Interreader agreement showed a substantial agreement (kappa = 0.613) for T2WI, and a substantial agreement (kappa = 0.737) for T2WI with DWI. CONCLUSION: For predicting SVI, T2WI with DWI showed a better diagnostic performance than T2WI alone. Additionally, the accuracy of the less experienced reader using T2WI with DWI showed a significant improvement as compared with T2WI alone.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号