Increasingly advanced applications of polymer fibers are driving the demand for new, high-performance fiber types. One way to produce polymer fibers is by electrospinning from polymer solutions and melts. Polymer melt electrospinning produces fibers with small diameters through solvent-free processing and has applications within different fields, ranging from textile and construction, to the biotech and pharmaceutical industries. Modeling of the electrospinning process has been mainly limited to simulations of geometry-dependent electric field distributions. The associated large change in viscosity upon fiber formation and elongation is a key issue governing the electrospinning process, apart from other environmental factors. This paper investigates the melt electrospinning of aerogel-containing fibers and proposes a logistic viscosity model approach with parametric ramping in a finite element method (FEM) simulation. The formation of melt electrospun fibers is studied with regard to the spinning temperature and the distance to the collector. The formation of PET-Aerogel composite fibers by pneumatic transport is demonstrated, and the critical parameter is found to be the temperature of the gas phase. The experimental results form the basis for the electrospinning model, which is shown to reproduce the trend for the fiber diameter, both for polymer as well as polymer-aerogel composites. 相似文献
We sought: 1) to investigate the relationship between vascular wall shear stress and flow-mediated dilation (FMD) in humans, and 2) to investigate whether this relationship could explain why FMD is greater in small arteries.
BACKGROUND
Arterial wall shear stress (WSS) is considered to be the primary stimulus for the endothelial-dependent FMD response. However, the relationship between WSS and FMD has not been investigated in humans. Furthermore, FMD is greater in small arteries, though the reasons for this phenomenon are unclear.
METHODS
Using phase-contrast magnetic resonance angiography (PMRCA), we measured hyperemic WSS and FMD in 18 healthy volunteers. Peak systolic WSS was calculated assuming a blunted parabolic velocity profile. Diameter by PCMRA and by ultrasound was compared in nine subjects.
RESULTS
Flow-mediated dilation was linearly proportional to hyperemic peak systolic WSS (r = 0.79, P = 0.0001). Flow-mediated dilation was inversely related to baseline diameter (r = 0.62, P = 0.006), but the hyperemic peak WSS stimulus was also inversely related to baseline diameter (r = 0.47, P = 0.049). Phase-contrast magnetic resonance angiography and ultrasound diameters were compared in nine subjects and correlated well (r = 0.84, p < 0.0001), but diameter by PCMRA was greater (4.1 ± 0.7 mm vs. 3.7 ± 0.5 mm, P = 0.009).
CONCLUSIONS
Arterial FMD is linearly proportional to peak hyperemic WSS in normal subjects. Thus, the endothelial response is linearly proportional to the stimulus. Furthermore, the greater FMD response in small arteries is accounted for, at least partially, by a greater hyperemic WSS stimulus in small arteries. By allowing the calculation of vascular WSS, which is the stimulus for FMD, and by imaging a fixed arterial cross-section, thus reducing operator dependence, PCMRA enhances the assessment of vascular endothelial function. 相似文献