The results of embolisation of dural arteriovenous fistulas draining into the transverse or sigmoid sinus were evaluated in 20 patients. Tinnitus was the main symptom in all patients although one also suffered from vertigo and sudden deafness. Nine patients were treated with PVA (polyvinylalcohol) alone and 11 with combined PVA and bucrylate (isobutyl-2-cyanoacrylate) in 1–9 procedures. Recurrence of symptoms, requiring repeated procedures was common but at subsequent clinical follow up 10 patients had no tinnitus, 5 were improved and only 5 experienced no change. Complications occured in six patients: four had transient neurological symptoms and one of these also developed a necrotic wound which later healed. One patient suffered from a cranial nerve palsy and one had an intracranial haemorrhage after a transvenous embolisation. This last patient recovered completely. The best clinical results were achieved in small fistulas and fistulas treated with combined bucrylate and PVA. 相似文献
Recombinant human deoxyribonuclease I (rhDNase) is a new therapeutic agent developed to improve clearance of purulent sputum from the human airways. It is delivered by inhalation. Four jet nebulizers, T Up-Draft II (Hudson), Customized Respirgard II (Marquest), Acorn II (Marquest), and Airlife Misty (Baxter), were evaluated in vitro for their ability to deliver aerosols of rhDNase. The aerosols were generated from 2.5-mL aqueous solutions of rhDNase, at concentrations of either 1 or 4 mg/mL. In all experiments, the Pulmo-Aide Compressor (De Vilbiss) was used to supply the air to the nebulizers. Between 20 and 28% of the rhDNase dose initially placed in the nebulizers was delivered to the mouthpiece in the respirable range (1-6 µm). Evaluation of the rhDNase following nebulization in all four devices indicated that there was no loss in enzymatic activity and no increase in aggregation. Circular dichroism spectrophotometry indicated there was no change in either the secondary or the tertiary structure in rhDNase following nebulization. These results show that all four nebulizers are essentially equivalent in their ability to deliver respirable doses of rhDNase in an intact, fully active form. Changing the concentration of the solution in the nebulizer from 4 to 1 mg/mL rhDNase leads to a proportional reduction in the respirable dose delivered to the mouthpiece. 相似文献
1. The pharmacokinetics of Dalal-peptide T-NH2 (peptide T) was determined during phase I clinical trials in patients with acquired immunodeficiecy disease (AIDS) and AIDS related complex (ARC). Drug levels were determined by specific RIA, and in some cases with HPLC analysis, after intraveneous (i.v.) or intranasal (i.n.), via metered sprayer, administration.
2. The plasma kinetics appeared to be bi-phasic with a first compartment half-life of 30 to 60 minutes and a second plasma clearence rate of 4 to 6 hours, observed for both routes of administration. Peptide T, in one individual was confirmed to be present at 6 hrs in plasma, determined after HPLC isolation followed by specific RIA.
3. Bioavailabilty, determined for a 2 mg test dose in six individuals was 9.3 ± 6.9 nmol/L. Peak plasma levels of 41 ± 30 nmol/L after 10 mg i.n., 2.8 ± 5.9 nmol/L after 2mg i.n., and 0.13 ± 0.07 nmol/L after 0.4 mg i.n. were observed. In two individuals tested, peptide T was detected in CSF at levels 20% of the corresponding plasma level 90 and 145 minutes post i.v. administration. Peptide T was not detected in urine. I.N. administration was well tolerated for times up to 21 months. 相似文献