IntroductionHip displacement is common in cerebral palsy (CP) and is related to the severity of neurological and functional impairment. It is a silent, but progressive disease, and can result in significant morbidity and decreased quality of life, if left untreated. The pathophysiology of hip displacement in CP is a combination of hip flexor-adductor muscle spasticity, abductor muscle weakness, and delayed weight-bearing, resulting in proximal femoral deformities and progressive acetabular dysplasia. Due to a lack of symptoms in the early stages of hip displacement, the diagnosis is easily missed. Awareness of this condition and regular surveillance by clinical examination and serial radiographs of the hips are the key to early diagnosis and treatment.Hip surveillance programmesSeveral population-based studies from around the world have demonstrated that universal hip surveillance in children with CP allows early detection of hip displacement and appropriate early intervention, with a resultant decrease in painful dislocations. Global hip surveillance models are based upon the patients’ age, functional level determined by the Gross Motor Function Classification system (GMFCS), gait classification, standardized clinical exam, and radiographic indices such as the migration percentage (MP), as critical indicators of progressive hip displacement.ConclusionDespite 25 years of evidence showing the efficacy of established hip surveillance programmes, there is poor awareness among healthcare professionals in India about the importance of regular hip surveillance in children with CP. There is a need for professional organizations to develop evidence-based guidelines for hip surveillance which are relevant to the Indian context. 相似文献
This is a Brighton Collaboration case definition of thrombosis and thromboembolism to be used in the evaluation of adverse events following immunization, and for epidemiologic studies for the assessment of background incidence or hypothesis testing. The case definition was developed by a group of experts convened by the Coalition for Epidemic Preparedness Innovations (CEPI) in the context of active development of SARS-CoV-2 vaccines. The case definition format of the Brighton Collaboration was followed to develop a consensus definition and defined levels of certainty, after an exhaustive review of the literature and expert consultation. The document underwent peer review by the Brighton Collaboration Network and by selected expert reviewers prior to submission. 相似文献
BackgroundCold snare polypectomy (CSP) is a promising technique for the removal of sessile serrated polyps (SSPs) ≥ 10 mm. However, the efficacy and safety of this technique remain undetermined.AimsWe aimed to comprehensively evaluate the efficacy and safety of CSP for SSPs ≥ 10 mm.MethodsPubMed, EMBASE, Web of Science and Cochrane Library were searched up to January 2021.ResultsA total of 10 studies consisting of 1727 SSPs (range, 10–40 mm) from 1021 patients were included. The overall rates of technical success, adverse events (AEs) and residual SSPs were 100%, 0.7% and 2.9%, respectively. Subgroup analysis showed that the rates of technical success and AEs were comparable between CSP and cold endoscopic mucosal resection (EMR) (99.9% vs. 100% and 1.3% vs. 0.5%, respectively), between the proximal and distal colon (100% vs. 99.9% and 0.3% vs. 0, respectively), and between polyps of 10–19 mm and ≥20 mm (99.8% vs. 100% and 0.9% vs. 0, respectively). However, subgroup analysis showed that the rate of residual SSPs was slightly lower in CSP compared with cold EMR (1.3% vs. 3.9%), as well as in polyps of 10–19 mm compared with those ≥20 mm (3.1% vs. 4.7%).ConclusionCSP was an effective and safe technique for removing SSPs ≥ 10 mm. 相似文献
PurposeTo investigate the safety and efficacy of an aqueous polyethylene glycol-based liquid embolic agent, Embrace Hydrogel Embolic System (HES), in the treatment of benign and malignant hypervascular tumors.Materials and MethodsA prospective, single-arm, multicenter study included 8 patients, 5 males and 3 females, with a median age of 58.5 years (30–85 years), who underwent embolization in 8 tumors between October 2019 and May 2020. Technical success was defined as successful delivery of HES to the index vessel, with disappearance of >90% of the targeted vascular enhancement or, for portal vein embolization, occlusion of the portal branches to the liver segments for future resection. The volume of HES administered, ease of use (5 point Likert scale), administration time, and adverse events (AEs) were recorded. Evaluation was performed at 7, 30, and 90 days via clinical assessment and blood testing, and follow-up imaging was performed at 30 days.ResultsEight patients were enrolled, and 10 embolizations were performed in 8 lesions. Tumors included hepatocellular carcinoma (n = 4), renal angiomyolipoma (n = 3), and intrahepatic cholangiocarcinoma (n = 1). Technical success was 100%, and the average ease of use was 3.3 ± 1.0 SD. The HES delivery time was 1–28 minutes (median, 16.5 minutes), and the HES volume injected was 0.4–4.0 mL (median, 1.3 mL). All patients reached 30-day follow-up with imaging, and 6 patients reached 90-day follow-up. There were 3 serious AEs in 2 patients that were unrelated to the embolic agent.ConclusionHES resulted in a 100% embolization technical success rate. The product ease of use was acceptable, and no target vessel recanalization was noted on follow-up imaging at 30 days. 相似文献
In this paper, we argue that understanding and addressing the problem of poor-quality medical products requires a more interdisciplinary approach than has been evident to date. While prospective studies based on rigorous standardized methodologies are the gold standard for measuring the prevalence of poor-quality medical products and understanding their distribution nationally and internationally, they should be complemented by social science research to unpack the complex set of social, economic, and governance factors that underlie these patterns. In the following sections, we discuss specific examples of prospective quality surveys and of social science studies, highlighting the value of cross-sector partnerships in driving high-quality, policy-relevant research in this area. 相似文献
Introduction: Pharmacovigilance is essential to monitoring the safety profiles of authorized medicines. Compared with small-molecule drugs, biological drugs are more complex, more susceptible to structural variability due to manufacturing processes, and have the potential to induce immune-related reactions, underscoring the importance of safety monitoring for these products. Although highly similar to reference products, biosimilars are not expected to be structurally identical. For these reasons, proper reporting of potential adverse drug reactions (ADRs) using distinguishable names and batch numbers is essential for accurate tracing of all biological drugs. To address the need for robust pharmacovigilance, the European Parliament and Council of the European Union provided legislation regarding pharmacovigilance of biologics in 2010.
Areas covered: This narrative review examines the current state of pharmacovigilance for biologics in the European Union (EU) and discusses relevant information on pharmacovigilance of biosimilars, the current EU pharmacovigilance system, and areas that could be improved.
Expert opinion: Although steps have been taken to improve pharmacovigilance of biologics in the EU, several enhancements can still be made, including additional training for healthcare professionals on ADR reporting, the use of 2D barcodes that enhance traceability, and an open discussion of potentially missed opportunities in the pharmacovigilance of biosimilars. 相似文献
BackgroundSafety signal detection in spontaneous reporting system databases and electronic healthcare records is key to detection of previously unknown adverse events following immunization. Various statistical methods for signal detection in these different datasources have been developed, however none are geared to the pediatric population and none specifically to vaccines. A reference set comprising pediatric vaccine-adverse event pairs is required for reliable performance testing of statistical methods within and across data sources.MethodsThe study was conducted within the context of the Global Research in Paediatrics (GRiP) project, as part of the seventh framework programme (FP7) of the European Commission. Criteria for the selection of vaccines considered in the reference set were routine and global use in the pediatric population. Adverse events were primarily selected based on importance. Outcome based systematic literature searches were performed for all identified vaccine-adverse event pairs and complemented by expert committee reports, evidence based decision support systems (e.g. Micromedex), and summaries of product characteristics. Classification into positive (PC) and negative control (NC) pairs was performed by two independent reviewers according to a pre-defined algorithm and discussed for consensus in case of disagreement.ResultsWe selected 13 vaccines and 14 adverse events to be included in the reference set. From a total of 182 vaccine-adverse event pairs, we classified 18 as PC, 113 as NC and 51 as unclassifiable. Most classifications (91) were based on literature review, 45 were based on expert committee reports, and for 46 vaccine-adverse event pairs, an underlying pathomechanism was not plausible classifying the association as NC.ConclusionA reference set of vaccine-adverse event pairs was developed. We propose its use for comparing signal detection methods and systems in the pediatric population. 相似文献