首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 156 毫秒
1.
目的:观察新型GyneFix IN致美宫内节育器(IUD)的临床性能。方法:将450例健康经产妇女分为3组,分别于月经间期放置GyneFix IN150例(GyneFixIN组)、GuneFix IN致美150例(GyneFix IN致美组)及TCu380A节育器150例(TCu380A组),分别于放置后1、3、6及12个月随访,以生命表法统计三种IUD的效果。结果:GyneFix IN致美组使用1年无妊娠。脱落率及与IUD使用有关的终止率均低于GyneFix IN组及TCu380A组;而在月经周期的改变、月经量的改变、子宫淋漓出血方面亦低于GyneFix IN组及TCu380A组。结论:此种无支架、铜表面积大有固定系统加入吲哚美辛的GyneFix IN致美IUD具有低脱落率、疼痛轻、出血及副反应少的特点,有推广前景。  相似文献   

2.
目的:评价GyneFix330与TCu220C、TCu380A宫内节育器(IUD)的有效性、副反应和续用情况。方法:电子和手工检索1990年1月~2009年11月中英文发表的相关文献,按循证医学方法对纳入文献进行分析评价。结果:纳入26篇正式发表的随机对照临床试验文献。与TCu220C IUD相比,GyneFix330IUD的12个月和24个月带器妊娠率和脱落率较低;6个月、12个月和24个月的经期延长、经量增多、腰腹痛和不规则出血发生率较低;12个月因症取出率较低,续用率则较高。GyneFix330和TCu380A IUD12个月、24个月、36个月和9年的带器妊娠率均低于2.50/100妇女。两组6个月、12个月、24个月和36个月的月经量增多、白带增多和不规则出血发生率互有优劣。与TCu380A IUD相比,Gyne-Fix330IUD12个月和24个月的因症取出率接近,续用率略高。结论:GyneFix330IUD临床应用效果优于TCu220C IUD,与TCu380A IUD相差不大,仍需长期大样本临床观察予以确证。  相似文献   

3.
剖宫产术后放置吉妮固定式宫内节育器150例临床观察   总被引:1,自引:0,他引:1  
目的比较剖宫产术后放置吉妮固定式宫内节育器(GyneFix IN IUD)和TCu220C IUD临床使用效果。方法知情选择剖宫产术后者放置IUD妇女300例,分为观察组(150例)放置GyneFix IN IUD和对照组(150例)放置TCu220C IUD,并进行24个月随访观察。结果GyneFix IN IUD的脱落率、带器妊娠率、因症取出率及累积续用率与TCu220C IUD比较差异有统计学意义(P〈0.01)。结论剖宫产术后放置GyneFix IN IUD的临床效果明显优于TCu220C IUD,可广泛应用于剖宫产术后。  相似文献   

4.
两种新型含铜IUD对宫颈沙眼衣原体阳性率影响的研究   总被引:3,自引:0,他引:3  
本文报道了同期放置的TCu380A及GyneFix两种新型含铜宫内节育器在放置1年及2年时与对照组宫颈砂眼衣原体(CT)阳性率的比较。TCu380A组放置1年时阳性率为5.63%,2年时为4.92%;GyneFix组放置1年时阳性率为4.62%,2年时为5.08%,两组含铜IUD放置1年及2年时各组比较差别均无显著意义(P>0.05);对照组CT阳性率为15.18%,与上述各组比较差别均有显著意义(P<0.05)。本文结论认为含铜IUD对宫颈CT感染有抑制作用。  相似文献   

5.
IUD失败妇女再次放置GyneFix IN IUD的临床研究   总被引:4,自引:1,他引:3  
<正> 宫内节育器(IUD)是目前最广泛使用的可逆性生育控制方法,常因方法失败或副反应而终止使用。IUD失败者是否适宜再次置器,是育龄妇女和计划生育工作者所关注的共同问题。本研究通过对有放置金属IUD失败史的妇女,随机放置新型GyneFix IN IUD和TCu380A IUD,以观察临床效果。探讨放置金属IUD失败后再次放置GyneFix IN IUD的避孕效果及其放置期限。  相似文献   

6.
目的观察比较活性γCu380IUD、TCu380IUD及吉妮330IUD临床避孕效果。方法2003年11月~2005年12月本院选择自愿放置IUD的已婚育龄妇女300例,随机分成三组(各100例),分别放置活性γCu380IUD、TCu380IUD及吉妮330IUD,并于放置后1、3、6、12、24个月进行随访。结果三种IUD放置24个月后比较其脱落率、带器妊娠率、因症取出率及累积续用率均无统计学差异(p>0.05)。结论三种IUD均具有脱落低、带器妊娠率低、因症取出率低及累积续用率较高的优点,其避孕效果良好,可在临床上推广使用。  相似文献   

7.
不同分娩方式妇女放置三种IUD的术时评价   总被引:2,自引:1,他引:1  
目的:研究不同分娩方式妇女放置三种新型含铜宫内节育器(CulUD)的术时评价。方法:将观察对象按经阴道和经剖宫产的不同分娩方式分为两组,每组均随机放置CyneFix IN IUD、MCu功能性IUD和TCu380A IUD,记录两组放置不同种IUD的扩宫情况、置器疼痛反应和置器时间。结果:放置GyneFix IN IUD和TCu380A IUD在不同分娩方式组中扩宫率、痛觉评分、置器时间无显著差异(P>0.05)。放置MCu功能性IUD在剖宫产分娩组扩宫率为92.5%,显著高于阴道分娩组的33.3%(P<0.05);痛觉评分为8.62±0.82分,显著高于阴道分娩组(P<0.01);置器时间为(9.62±3.15)min,较另两种IUD置器时间显著延长(P<0.05)。结论:GyneFix IN IUD和TCu380A IUD置器术时扩宫率低、费时少,疼痛反应轻,不受分娩方式影响。  相似文献   

8.
目的:评价新型宫内节育器(IUD)GyneFix IUD和MCu IUD及传统节育器TCu220IUD的避孕效果。方法:以人工流产术后志愿放置IUD的690例为对象,随机分为3组,分别于人工流产术后即时放置Gyne Fix IUD、MCu IUD和TCu220IUD。结果:GyneFix IUD,MCu IUD和TCu220IUD使用12个月带器妊娠率分别为0.48%、0.85%、3.75%,脱落率分别为0.93%、0.85%、2.92%,因症取出率分别为2.80%、3.81%、6.25%,续用率分别为95.80%,94.49%,87.08%,放置IUD后月经异常发生率分别为8.88%、5.93%、12.5%。结论:GyneFix IUD、MCu IUD和TCu220IUD避孕效果均较理想,但TCu220IUD可能是放置型号不易掌握,带器妊娠、脱落、月经异常发生率较两种新型IUD高。  相似文献   

9.
周行  徐琳  马永红 《中国妇幼保健》2009,24(28):3998-3999
目的:评价人工流产术后即时放置活性γ型IUD、TCu380AIUD的临床效果。方法:采用前瞻性、随机对比方法对100例健康已生育的早孕妇女,在人工流产术后即时放置活性γ型IUD50例(活性γ型IUD组)、TCu380A50例(TCu380A组),于放置后的1、3、6、12个月随访,以生命表法统计两种IUD的终止情况。结果:使用12个月时,活性γ型IUD、TCu380A的妊娠率均为0.01/100妇女;脱落率分别为6.0/100妇女、8.0/100妇女,两组比较差别无统计学意义(P>0.05)。结论:人工流产术后即时放置活性γ型IUD、TC380A避孕效果好,脱落率相对较低,续用率高,安全,可接受性强,值得推广应用。  相似文献   

10.
目的:了解第三代爱母宫内节育器(MYCu IUD)在月经间期放置的临床效果、副作用及对生活质量的影响。方法:对要求放置IUD避孕的育龄妇女,在月经间期随机放置MYCu IUD(MYCu组,368例)与TCu 380AIUD(TCu380A组,369例),放置后1、3、6、12个月随访观察,记录使用情况。结果:置器后12个月MYCu组与TCu 380A组随访率分别为99.45%、100.00%;置器12个月累积续用率分别为每百妇女年94.02、91.87(P0.05);带器妊娠率分别为每百妇女年0.56、0.00(P=0.1703);脱落率分别为每百妇女年0.57、1.95(P=0.0947);无因IUD下移而停用者;因症终止率分别为每百妇女年3.01、6.03(P=0.0849)。置器后1、3、6个月副作用发生率MYCu组明显低于TCu380A组(P0.05)。两组对象相关生活质量均得到改善。结论:放置MYCu IUD较TCu 380AIUD疼痛和出血的副作用少,续用率、避孕效果与TCu 380AIUD相当,是一种临床效果好、副作用发生率较低的新型IUD。  相似文献   

11.
4种新型宫内节育器使用5年临床效果评价   总被引:25,自引:8,他引:17  
为较好掌握新型 IUD 的优点和特征,便于医务人员根据不同育龄妇女身体状况选择适当的 IUD 类型,本课题对2400例育龄妇女随机放置 TCu380A、三球头 TCu220C、MLCu375SL 和含药宫铜4种新型 IUD 使用5年间的终止原因进行临床多中心研究分析。结果表明:第二代活性 IUD具有安全、高效、长效的优点,其中尤以 TCu380A 具有较高续用率(78.1/100妇女),其妊娠率(带器妊娠及意外妊娠)为4.9/100妇女,脱落率也最低,为6.9/100妇女(P<0.05);MLCu375SL 城市组使用效果明显优于农村组,其5年续用率分别为80.54/100妇女和66.89/100妇女(P<0.05);农村组脱落率最高,为14.6/100妇女(P<0.05);含药宫铜 IUD 置器后月经量增加的症状明显减少,因症取出率最低,5年末为3.7/100妇女(P<0.01);;三球头 TCu220C 具有低因症取出率和低脱落率的优点,但带器妊娠率最高,为8.4/100妇女(P<0.01)。结果提示:T 铜 IUD 的脱落率相对较低;三球头 TCu220C 的球头和含药宫铜 IUD 所含的消炎痛在减少副反应方面有一定的作用;ML-Cu375SL 适合城市妇女使用。  相似文献   

12.
目的:观察元宫铜300、TCu380A和活性165宫内节育器(IUD)使用效果,探讨改善其使用价值的途径。方法:采用多中心随机比较性临床研究方法,自2007年7月3日~2008年11月21日,在全国6个省22家计划生育服务机构,对符合条件的健康育龄期妇女,随机分别放置元宫铜300、TCu380A或活性165IUD,比较避孕效果、失败率和不良反应的发生情况。结果:共接收观察对象3299例,放置元宫铜300、TCu380A和活性165IUD分别为1104、1104和1091例。12个月末失访率为0.24%(8/3299)。观察期间无子宫穿孔和盆腔感染发生。在IUD使用失败的各种原因中,3种IUD带器妊娠、下移取出终止率比较,差异均无统计学意义(P0.05);完全脱落以活性165最高(终止率为2.09/百妇女年),与元宫铜300(终止率为0.84/百妇女年)和TCu380AIUD(终止率为0.75/百妇女年)分别比较,差异均有统计学意义(P0.05);放置活性165IUD有4例发生意外妊娠(终止率为0.38/百妇女年),其他两种IUD各有1例(终止率均为0.11/百妇女年)。3种IUD中因出血和(或)疼痛的终止率以元宫铜300IUD最高,TCu380AIUD次之,活性165IUD最低,差异有统计学意义(P0.05)。结论:3种IUD各有优缺点,应综合考虑适用对象与IUD的特点,以提高IUD的实际使用价值。  相似文献   

13.
BACKGROUND: Intrauterine devices (IUDs) are safe and effective methods of long-term reversible contraception. The design and copper content as well as placement of the copper on IUDs could affect their effectiveness and side effect profile. We compared different copper IUDs for their effectiveness and side effects. STUDY DESIGN: We searched multiple electronic databases with appropriate keywords and names of the IUDs known to be on the market. We searched the reference lists of papers identified and contacted authors when possible. There was no language restriction. Randomized controlled trials comparing different IUDs that reported on clinical outcomes were considered for inclusion. Two reviewers independently extracted data on outcomes and trial characteristics. We combined the trial results in meta-analyses and expressed results as rate difference (RD) using a fixed-effects model with 95% confidence interval (CI). In the presence of significant heterogeneity, a random-effects model was applied. RESULTS: We included 35 trials, resulting in 18 comparisons of 10 different IUDs in approximately 48,000 women. TCu380A was more effective in preventing pregnancy than MLCu375 (RD 1.70%, 95% CI 0.07-2.95% after 4 years of use). TCu380A was also more effective than MLCu250, TCu220 and TCu200. There tended to be fewer pregnancies with TCu380S compared to TCu380A after the first year of use, a difference which was statistically significant in the fourth year (RD -1.62%, 95% CI -3.00% to -0.24%). This occurred despite more expulsions with TCu380S (RD 3.50%, 95% CI 0.36-6.63% at 4 years). MLCu375 was no more effective than TCu220 at 1 year of use, or MLCu250 and NovaT up to 3 years. Compared to TCu380A or TCu380S, none of the IUDs showed any benefits in terms of bleeding or pain or any of the other reasons for early discontinuation. None of the trials that reported events at insertion found one IUD easier to insert than another or caused less pain at insertion. There is no evidence that uterine perforation rates vary by type of device. There are minimal randomized data on IUD use in nulliparous women. CONCLUSIONS: TCu380A and TCu380S appear to be more effective than other IUDs. No IUD showed consistently lower removal rates for bleeding and pain in comparison to other IUDs. There is no evidence that any particular framed copper device is better suited to women who have not had children.  相似文献   

14.
目的:评价阴道分娩妇女在月经恢复后放置3种宫内节育器(IUD)的有效性,为育龄妇女知情选择IUD提供参考依据。方法:阴道分娩妇女在月经恢复后知情选择分别放置吉妮IUD(吉妮组148例)、爱母IUD(爱母组223例)和花式IUD(花式组232例),并进行1年随访,比较3种IUD的临床效果。结果:放置术中和观察期间未发现子宫穿孔。放置1年时吉妮组和爱母组均无妊娠发生,花式组4例带器妊娠,3组间差异有统计学意义(P=0.0399)。花式IUD的脱落率最高(2.2/百妇女年),因症取出率以爱母组最高(2.27/百妇女年),与IUD相关的终止率以吉妮组最低(2.75/百妇女年),爱母组为3.60/百妇女年,花式组为5.65/百妇女年,但组间差异无统计学意义。结论:本观察的3种IUD均适合在阴道分娩月经恢复后放置。  相似文献   

15.
目的:比较研究产后即时放置吉娜宫内节育器(IUD)与产后未放置IUD或放置其他类型IUD的临床效果.方法:计算机检索中文数据库CNKI(2002~2013)、CBMdisc(2002~ 2013)、万方(2002~ 2013)、维普(2002~ 2013),纳入有关吉娜IUD临床随机或临床对照试验研究,然后采用RevMan 5.0软件进行meta分析.结果:共检索到367篇文献,根据纳入排除标准,最终纳入11篇已发表文献.结果:剖宫产后即时放置吉娜IUD与未即时放置IUD相比较,均未发现放置吉娜对产时、产后2h和24 h出血量以及恶露持续时间,术后产褥病发生率,子宫内膜炎的发生有影响.与胎盘娩出后同期放置Fix TCu220M IUD相比,吉娜组的不适主诉率(9.6%)明显低于Fix TCu220M组(P<0.05).剖宫产后即时放置吉娜IUD与剖宫产后6个月放置TCu380 IUD比较,随访12个月时,吉娜组月经异常发生率和腰腹痛发生率均低于TCu380组(P<0.05).结论:产后即时放置吉娜IUD不会对产妇的产后恢复造成不良影响,其无支架的设计能够有效减少副反应的发生.  相似文献   

16.
四种宫内节育器的对比研究   总被引:14,自引:4,他引:10  
本研究用实验流行病学方法,按随机分配原则对比了TCu380A、TCu220三球头、MLCu375SL、含药宫铜IUD四种宫内节育器(以下简称IUD)在江苏省育龄妇女中的使用效果。从1991年10月至1992年3月随机放置四种IUD,其中:TCu380A 593例,TCu220三球头606例,MLCu375SL 600例,含药宫铜IUD601例,共计2400例,农村、城市受试对象各为1200例。置器24个月时四种IUD累积续用率分别为:TCu380A 87.34/百妇女年,TCu220三球头88.41/百妇女年,MLCu375SL 87.32/百妇女年,含药宫铜型88.18/百妇女年,组间比较无显著差异(P>0.05);因妊娠、脱落、出血/疼痛终止率,四种IUD间均无显著差异;含药宫铜IUD明显降低出血副反应的发生率;按城、乡分组在24个月时农村组续用率较高,对此结果进行了探讨。  相似文献   

17.
The Copper T 380A (TCu 380A), Lippes Loop D (LLD) and the Multiload Cu 375 (MLCu 375) IUDs were evaluated for safety and efficacy in a multicenter randomized clinical trial in Indonesia. A total of 2992 women were enrolled into the study and data for 2845 women were analyzed (147 cases did not meet protocol criteria). Although study IUDs were randomly assigned, LLD users in this study were older and of higher parity than TCu 380A and MLCu 375 users. The 24-month gross cumulative life-table pregnancy rates for TCu 380A, LLD and MLCu 375 users were 1.2, 2.2 and 2.7, respectively. The 24-month expulsion rates for TCu 380A, LLD and MLCu 375 users were 6.7, 7.5 and 5.3, respectively. Overall, 24-month continuation rates were 85.5%, 85.0% and 85.4% for the respective device groups. Differences in both gross and age- and parity-adjusted life-tables rates for the major outcome variables were not statistically significant at 24 months postinsertion. The study suggests that the TCu 380A, LLD and MLCu 375 IUDs seem to be safe and effective contraceptive options for Indonesian women.  相似文献   

18.
TCu380A、TCu220C和MLCu375宫内节育器系统评估   总被引:4,自引:4,他引:4  
目的 :评价TCu380A、TCu2 2 0C、MLCu375三种宫内节育器的有效性、副反应和可接受性。方法 :见中国计划生育学杂志“我国常用口服避孕药和宫内节育器系统评估的方法概述”(2 0 0 5年 1期 17页 )。结果 :TCu380AIUD妊娠率及脱落率均低于MLCu375IUD ,副作用发生率高于MLCu375IUD ,续用率等同或高于MLCu375IUD ,临床综合效能与MLCu375IUD相近 ;TCu380AIUD妊娠率低于TCu2 2 0CIUD ,脱落率及安全性与TCu2 2 0CIUD相似 ,放置满 5年后续用率高于TCu2 2 0CIUD ;MLCu375IUD妊娠率略低于TCu2 2 0CIUD ,脱落率低于或等同于TCu2 2 0CIUD ,二者的副反应发生率相似 ,临床综合效能优于TCu2 2 0CIUD。建议 :可以继续使用TCu380AIUD、MLCu375IUD和TCu2 2 0CIUD ,并且加大TCu380AIUD和MLCu375IUD的使用份额。在总体上应优先考虑提供铜表面积≥ 30 0mm2 的宫内节育器  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号