首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 453 毫秒
1.
目的测量股骨偏心距的大小并探讨其临床意义。方法对100例正常双髋关节X线片进行影像学测量,测量参数包括股骨偏心距、颈干角、股骨头直径、外展肌力臂、体重力臂、小转子中点及其上下20mm的冠状径、峡部直径和髓腔闪烁指数等,SPSS10.0统计学软件分析股骨偏心距与外展肌力臂、体重力臂、股骨髓腔各解剖参数的相关关系及男女各参数间的差异,并将测量结果与国内外学者的测量参数进行比较。结果本组股骨偏心距大小为(36.64±5.31)mm;股骨偏心距与外展肌力臂呈明显的正相关(r=0.73,P0.01),与股骨颈干角呈负相关(r=-0.46,P0.01),与其它股骨近端解剖参数无明显相关性。男女两性间股骨偏心距、颈干角、股骨头直径、外展肌力臂有显著性差异(P0.05)。本组股骨偏心距、颈干角与白种人有显著性差异(P0.01)。结论股骨偏心距大小为(36.64±5.31)mm,重建股骨偏心距有利于恢复外展肌力臂,重建正常髋关节生物力学。  相似文献   

2.
目的 分析重建股骨偏心距对人工全髋关节置换术后关节功能的影响。 方法 作者选择2005年01月至2008年01月间行初次单侧人工全髋关节置换术患者68例,随访时间9~24个月,平均19.2个月。手术均采用髋关节前外侧入路,使用Zweymüller双锥形螺旋臼及SL-PLUS矩形直柄(颈干角135°,股骨头假体的直径均为28 mm)。对比术前术后双髋关节正位X线片,测量股骨偏心距、髋外展肌力臂及双下肢长度,记录手术前后髋关节活动度及Harris评分,应用SPSS13.0统计软件分析股骨偏心距与其他指标的相关性。 结果 ①股骨偏心距与髋外展肌力臂具有正相关性(r=0.534,P<0.001)。②髋关节术后活动度、Harris评分与股骨偏心距均存在明显回归相关关系(r=0.403,0.344,P<0.001)。③股骨偏心距重建与否对下肢长度的影响存在显著性差异(x2=4.23,P<0.05)。 结论 在人工全髋关节置换术中,重建股骨偏心距可增加髋外展肌力,改善髋关节的活动功能及稳定性。  相似文献   

3.
目的 探讨从跟骨内侧定位、经载距突置入导向针后,由跟骨外侧壁置入载距突螺钉的可行性及精确度,为临床手术方案设计及导向器械的研发改进提供参考依据。 方法 选取10具20侧成人尸体标本,在跟骨外侧做“L”形延长切口,暴露跟骨外侧结构及距下关节,采用自主研发的“跟骨内侧定位载距突螺钉导向器”辅助载距突螺钉置入。首先,从内侧将“定位针”置入距下中关节,将导向器“内侧臂”的“定位孔”套牢定位针,调整“内侧臂”使“导向通道”位于载距突中心,安装“外侧臂”与“手柄”固定。调整“外侧臂”位置,经“导向通道”从内向外穿入跟骨一枚“导向针”,C臂透视提示“导向针”位置理想后,自跟骨外侧壁沿“导向针”用空心钻钻孔,测深后拧入合适的载距突螺钉。最后行CT扫描,利用CT图像评估置入螺钉的精确度。过程中采集相关数据,评估导向器的功能。 结果 肉眼观察标本,所有的导向针位于载距突内,其中65%位于载距突中心,25%偏下方,10%偏后方。在内侧,75%的导向针穿过胫后肌腱,15%位于胫后肌和趾长屈肌腱之间,10%穿经趾长屈肌腱上1/3。在外侧,导向针出针点与跟骰关节的距离为(38.03±5.60)mm,与后关节面的距离为(15.01±3.38)mm,螺钉平均长度为(44.80±3.59)mm。CT扫描图像可见,所有螺钉位于载距突内,有2例穿透上方骨皮质,无螺钉穿出载距突下方、前方及后方骨皮质。 结论 采用跟骨内侧定位法,在自主设计的导向器引导下,可提高载距突螺钉置入的准确性,降低螺钉进入关节、跟骨内侧皮质等并发症。  相似文献   

4.
目的 探讨从跟骨内侧定位、经载距突置入导向针后,由跟骨外侧壁置入载距突螺钉的可行性及精确度,为临床手术方案设计及导向器械的研发改进提供参考依据。 方法 选取10具20侧成人尸体标本,在跟骨外侧做“L”形延长切口,暴露跟骨外侧结构及距下关节,采用自主研发的“跟骨内侧定位载距突螺钉导向器”辅助载距突螺钉置入。首先,从内侧将“定位针”置入距下中关节,将导向器“内侧臂”的“定位孔”套牢定位针,调整“内侧臂”使“导向通道”位于载距突中心,安装“外侧臂”与“手柄”固定。调整“外侧臂”位置,经“导向通道”从内向外穿入跟骨一枚“导向针”,C臂透视提示“导向针”位置理想后,自跟骨外侧壁沿“导向针”用空心钻钻孔,测深后拧入合适的载距突螺钉。最后行CT扫描,利用CT图像评估置入螺钉的精确度。过程中采集相关数据,评估导向器的功能。 结果 肉眼观察标本,所有的导向针位于载距突内,其中65%位于载距突中心,25%偏下方,10%偏后方。在内侧,75%的导向针穿过胫后肌腱,15%位于胫后肌和趾长屈肌腱之间,10%穿经趾长屈肌腱上1/3。在外侧,导向针出针点与跟骰关节的距离为(38.03±5.60)mm,与后关节面的距离为(15.01±3.38)mm,螺钉平均长度为(44.80±3.59)mm。CT扫描图像可见,所有螺钉位于载距突内,有2例穿透上方骨皮质,无螺钉穿出载距突下方、前方及后方骨皮质。 结论 采用跟骨内侧定位法,在自主设计的导向器引导下,可提高载距突螺钉置入的准确性,降低螺钉进入关节、跟骨内侧皮质等并发症。  相似文献   

5.
目的探讨距骨颈骨折治疗方案的选择以及疗效相关因素分析。方法距骨颈骨折15例,男13例,女2例。年龄16~63岁,平均40.5岁,合并腰椎、髋臼、跟骨、外踝骨折各1例。开放骨折2例。陈旧性骨折2例(〉1个月)。按Hawkins骨折分类:Ⅰ型3例、Ⅱ型9例、Ⅲ型3例。Ⅰ型骨折采用膝下管型石膏固定,其中1例复诊中因移位行切开复位松质骨螺钉固定。Ⅱ型骨折均行切开复位,克氏针或松质骨螺钉固定。Ⅲ型骨折1例开放性骨折,急诊行清创缝合,手法+撬拔复位,脱位整复。一周后在C臂机引导下,采用二枚直径4.0mm中空螺钉由后向前固定距骨颈,1例急诊手术切开复位,克氏针内固定。结果本组13例获得随访,时间4~24个月,平均12.3个月。13例中发生距骨体缺血性坏死5例,其中Ⅱ型骨折4例,Ⅲ型骨折1例。另2例未统计在内。1例外院病例术后并发伤口感染长期不愈,行小腿截肢术。1例患者拒绝手术治疗。按Hawkims疗效标准,优4例,良4例,可3例,差2例,优良率69%。结论对无移位的距骨颈骨折,行膝下管型石膏固定6~12周,并定期拍片复查,距骨颈骨折脱位应急诊复位和可靠的内固定。以2枚拉力螺钉内固定为宜,尽量减少并发症。对距骨体缺血性坏死,或创伤性关节炎,则根据患者的实际情况采取相应治疗措施。  相似文献   

6.
目的:为踝、距下关节病变及损伤的诊断、修复和重建提供矢状断层解剖学基础。方法:用成年男尸右足标本5例,置冰柜冻硬后,每例切制4个踝及后足部矢状断层标本。结果:胫距关节矢状径最长为31.9mm,距骨滑车与胫骨关节软骨厚各为2.5mm与2.4mm,胫距关节间隙为2.6mm,内侧韧带厚为3.1mm;前、后距下关节软骨厚分别为1.5mm、1.2mm与1.7mm、1.4mm,关节间隙为0.8mm与1.4mm,后距下关节矢状径最长为18.9mm,距跟骨间韧带长8.6mm,矢状径为2.6mm。结论:本文结果为临床踝、距下关节疾患的诊治及关节镜技术提供了解剖学资料。  相似文献   

7.
目的 探讨自行研制的跟骨载距突螺钉导向器在尸体标本与临床上辅助固定跟骨载距突的准确性。 方法 (1)采用30例成人新鲜及防腐足部标本为研究对象,用2.5 mm克氏针沿跟骨载距突螺钉导向器植入载距突内,每具标本打入1枚克氏针,观察克氏针打入载距突情况; (2)在临床上收集跟骨骨折25例(28足),根据Sanders等分型,II型9例,Ⅲ型11例,IV型8例,采用该载距突螺钉辅助治疗跟骨骨折,通过X线检查螺钉打入载距突情况。 结果 (1)所有标本均置入1枚固定载距突的克氏针,其中1枚穿过载距突前下,其余29枚均从载距突的中间通过,精确率达96.7%。(2)临床病例X线片显示共置入28枚固定载距突的螺钉,其中1枚穿过载距突前方,其余27枚均从载距突的中间通过,精确率达96.4%。 结论 采用该导向器辅助固定跟骨的载距突,明显提高螺钉或克氏针植入载距突的准确性,在临床病例上,避免载距突螺钉位置偏差导致人为医源性并发症的发生,使用方便,适合临床推广应用。  相似文献   

8.
股骨距的应用解剖   总被引:6,自引:1,他引:5  
目的:为进一步研究股骨距的力学特性和临床应用提供可靠的形态学资料。方法:应用去钙解剖,断面解剖和计算机图像处理技术。对40例成人股骨距进行了观察和测量。结果:股骨距为股骨上段内部由股骨颈后部中部延伸至小转子前下方的一纵行密质骨板,可分为内侧致密部和外侧分层部。显示了股距的全貌和断面形态,详细报道了有关股骨距和股骨相关结构的数据。结论:股骨距的位置,确切的形态结构和各项测量数据有利于进一步探讨其力学特性,也有利于临床应用。  相似文献   

9.
文题释义: 肱骨距:为肱骨头下方内侧壁的一段骨皮质区域,位于肱骨头下内侧及背侧区,该区域含有较多的骨小梁,肱骨近端三、四部分骨折时常累及肱骨距,而“距螺钉”放置在该区域能支撑肱骨头,维持内侧柱稳定。肱骨距概念的提出是为了更好地治疗肱骨近端骨折,因此很好的理解肱骨距的重要性及了解肱骨距粉碎的形态对于治疗肱骨近端骨折非常重要。 内侧柱支撑:肱骨近端骨折常伴有肱骨距粉碎,Philos钢板固定后,容易出现肱骨头坏死、螺钉穿出关节面等并发症,通过使用特殊的距螺钉置入肱骨距区域或使用同种异体腓骨髓内支撑,能给肱骨近端内侧柱提供有效支撑,防止术后肱骨头内翻等并发症的发生。 背景:肱骨近端骨折的保头治疗是创伤骨科的难点,而如何获得内侧柱支撑是近年研究的热点。 目的:总结肱骨距的一般概念、临床意义及作用、常见的损伤原因、钢板固定治疗进展,以期提高临床医师对肱骨距的认识,减少手术并发症的发生。 方法:由第一作者检索2004至2019年万方、知网、维普、PubMed、Web of science、Springer Link等数据库收录的关于肱骨近端内侧壁治疗及研究进展的相关文献。英文检索词为“proximal humeral fracture,Philos,infermedial screw,calcar screw,fibularallograft,middle support”,中文检索词为“肱骨近端骨折,肱骨距,内侧柱,钢板,腓骨移植”,同时对文章中参考文献进行人工检索。按照纳入排除标准最终共纳入51篇文献进行综述。 结果与结论:①目前对于肱骨距的范围定义仍不明确,累及肱骨距的骨折目前无统一的分型标准,X射线片显示的肱骨距损伤模式常常与骨折实际情况不符,累及肱骨距的骨折往往是复杂的骨折。临床医师对肱骨距认识、重视程度不够是引起肱骨距损伤和未能得到很好修复的主要原因;②钢板治疗仍是肱骨近端骨折的首选,对于“可修复性内侧壁”,根据肱骨距损伤情况决定重建内侧柱方式,使用距螺钉、同种异体腓骨髓内植骨、骨水泥增强、内侧钢板都是可行的方法,术中实现内侧壁解剖复位、获得内侧柱的有效支撑能帮助减少术后并发症,而内侧钢板的使用需要更多研究进一步验证,肩袖修复对内侧柱支撑也是至关重要的;③肱骨距的范围需要达成统一的观点,充分了解肱骨距的重要性对于肱骨近端骨折治疗至关重要。术前应详细了解肱骨距的骨折模式,选择最佳手术方式,术中实现内侧壁的解剖复位、获得内侧柱的有效支撑可减少骨折术后并发症,术中肩袖的良好修复也是患者取得较好功能很重要的一环。 ORCID: 0000-0002-5163-1529(徐鹏) 中国组织工程研究杂志出版内容重点:人工关节;骨植入物;脊柱;骨折;内固定;数字化骨科;组织工程  相似文献   

10.
目的通过颈椎X射线平片评估提供理想C1侧块螺钉的置钉钉道及置钉位置。方法回顾性分析40例接受C1侧块螺钉手术患者临床资料,共完成79枚C1侧块螺钉。通过颈椎正位X射线分析C1侧块螺钉钉尾和钉尖的位置,通过颈椎侧位X射线分析螺钉长度及高度并分为0°、Ⅰ°、Ⅱ°;通过术后CT平扫分析螺钉是否破出侧块皮质、螺钉侧块骨质侵占的百分比、双皮质螺钉、螺钉超出侧块皮质的长度以及对临近关节的干扰。结果当正位X射线螺钉钉尖位于侧块内缘内侧(Tip 0)时所有患者均出现侧块皮质破坏,但螺钉钉尾位于侧块外缘内侧(Head 0)及经过侧位外缘时(HeadⅠ)未出现侧块皮质破坏,当钉尾经过侧块外缘(HeadⅠ)且钉尖位于侧块内侧半(TipⅠ)时螺钉侧块骨质侵占率为97.6%,当螺钉钉尾位于侧块外缘内侧(Head 0)且钉尖位于侧块内侧半(TipⅠ)时螺钉侧块骨质侵占率为90.5%,当钉尾经过侧块外缘(HeadⅠ)且钉尖位于侧块外侧半(TipⅡ)时螺钉侧块骨质侵占率为86.4%。当侧位X射线螺钉钉尖超过寰椎前弓后侧半时所有螺钉均为双皮质螺钉,螺钉平均穿出皮质长度为1.9 mm,当螺钉位于寰椎前弓下半时有98%的患者相邻关节未受累。结论颈椎正位X射线提示当钉尾位于侧块外缘且钉尖位于侧块内侧半时C1侧块螺钉钉道最安全且最长,颈椎侧位X射线提示螺钉钉尖位于寰椎前弓的前下1/4时的双皮质螺钉不会损伤邻近关节,上述X射线结果对术中及术后评估C1侧块螺钉钉道及长度均有帮助。  相似文献   

11.
目的 :研究确定胸腰椎同一椎体的椎弓根进钉点间距离及其相关的最佳内倾进钉角 (最佳TSA) ,为手术操作提供一准确的数据。方法 :利用术前进钉椎体的椎弓根中部的CT检查 ,测定椎弓根进钉点间距及最佳TSA。结果 :利用该方法协助术中椎弓根螺钉的进钉操作 ,提高了椎弓根钉安装的质量及成功率。结论∶利用术前CT测定的椎弓根进钉点间距及确定最佳TSA协助术中椎弓根定位及进钉方向 ,是一种简单可靠的方法。  相似文献   

12.
This report expands on a study by Pryor [Pryor HB. Objective measurement of interpupillary distance. Pediatrics 1969: 44: 973 977] that related normal values of inner canthal distance (ICD), outer canthal distance (OCD) and interpupillary distance (IPD) for Whites, Asians and Mexican Americans. To date, no similar values have been reported for Blacks. Utilizing a sample (n = 931: 485 males; 446 females) of black people (range, birth 24 years), OCD, ICD, and head circumference (HC) were measured and tabulated. We calculated mean IPD according to Pryor's formulation and report that the general mean OCD and ICD in our sample differed significantly from, and were consistently higher than, Pryor's reported measurements for White males and females at each age level (p < 0.001). However, ICD in our sample was significantly lower at birth in both sexes, appeared to increase at a more rapid rate relative to Whites during the first 3 months of life, and reached and maintained a higher value beyond the age of 3 months, with most age groups showing a significant difference in mean ICD measurements. At each age level, the mean IPD values in Whites and Blacks were significantly higher (p < 0.001). Based upon these findings, we suggest that interpupillary distance of Black children and adults be assessed according to the mean proportions for their race.  相似文献   

13.
For several years, lag screw osteosynthesis as described by ECKELT has been used for the surgical treatment of condylar fractures with predominantly positive results. However anatomical variations occasionally do not permit the use of the lag screw. The aim of the present study was to re-examine the anatomical requirements for using ECKELT's lag screw osteosynthesis. Based on a detailed structural analysis of 140 isolated cadaver rami mandibulae, it can be seen that they principally meet the anatomical requirements for the treatment of mandibular condylar fractures with lag screw osteosynthesis using 2.0 mm diameter screws. Rare, extreme anatomical variants emphasize the need for a stricter preoperative determination of the indications. Using spiral computerized tomography, it is possible to exactly assess preoperatively the existing anatomical situation of the ascending mandibular ramus on the planned frontal plane of the lag screw.  相似文献   

14.
目的 为髋臼后柱拉力螺钉导向器提供解剖学基础。 方法 收集31具半骨盆骨性标本(男性14例,女性17例),在髋臼后柱顺行置入拉力螺钉导针,测量进钉点的位置和进针方向。 结果 进针点与弓状缘的垂直距离女性为(0.96±0.32) cm,男性为(0.92±0.16) cm(P>0.05),进针点与骶髂关节前缘距离,女性为(2.43±0.66) cm,男性为(1.87±0.26) cm(P<0.05)。进钉方向与髂骨内板的后倾角∠θ女性为(59.68±6.28)°,男性为(56.75±3.22)°(P>0.05)、进钉方向与髂骨内板的外倾角∠φ女性为(41.27±2.76)°,男性为(34.31±2.78)°(P<0.05)。 结论 髋臼后柱骨折顺行拉力螺钉进钉点和进钉方向的测量为导向器的设计提供了解剖学基础,有助于提高髋臼后柱骨折顺行拉力螺钉置钉的成功率和准确性,降低手术风险和减轻手术损伤。  相似文献   

15.
目的:对我院设计的多功能股骨板(Multi Function Femoral Plate,MFFP)应用于股骨粗隆间不稳定骨折进行生物力学分析,为临床应用提供科学依据。方法:按生物力学原理,在12具新鲜尸体标本股骨上端内、外侧由有4枚应变片进行强刚度等分析。结果:实验研究表明:①多功能股骨板(MFFP)系统能降低股骨距上载荷并增加骨折断端的稳定必②加压滑动髁螺钉及DHS却增加了载荷并降低了骨折的稳  相似文献   

16.
目的 以中国北方汉族群体为基础制作22号染色体6个短串联重复序列(short tandem repeat,STR)连锁遗传图,比较22号染色本物理距离与遗传距离的关系。方法 用PCR方法对6个STR基因座进行分型及家系分析。结果 绘制出中国北方汉族群众22号染色本6个STR的遗传图,初步比较了22号染色体6个STR基因座间遗传与物理距离的关系。结论 22号染色本上6个STR间的遗传距离与物理距离存在较复杂的关系:6个STR基因座的遗传距离不仅与物理距离的大小有关,而且中国人与白人以及性别之间22号染色体物理距离与遗传距离的关系存在差异。  相似文献   

17.
目的 研究一种具有螺旋刀片结构新型骶髂拉力钉的生物力学性能。 方法 用临床中常用的骶髂经皮拉力钉作为对照。使用聚氨酯材料模拟松质骨,利用Instron力学试验机测试对比抗拔出性能。然后使用骨盆标本,以正常骨盆、单侧骶髂关节损伤骨盆、骶髂经皮拉力钉-单钉修复、骶髂经皮拉力钉-双钉修复骶髂关节损伤为对照,分析新型骶髂拉力钉修复正常站立姿态骶髂关节损伤的静态刚度和动态稳定性。 结果 新型骶髂拉力钉组拉力钉拔出后的聚氨酯材料破坏更小。新型骶髂拉力钉抗拔出的有效把持位移显著大于骶髂经皮拉力钉(P﹤0.05)。但骶髂经皮拉力的最大抗拔出力显著大于新型骶髂拉力钉(P﹤0.05)。骶髂关节损伤修复后,采用1枚骶髂新型骶髂拉力钉刚度显著高于骶髂经皮拉力钉-双钉修复组(P﹤0.05)。骶髂关节损伤组的位移振幅最大,其次为正常组;其余组别的位移振幅较为接近,但差异具有统计学意义(P﹤0.05)。新型骶髂拉力钉修复的动态稳定性最优,略优于骶髂经皮拉力钉-双钉修复组,骶髂关节损伤组的稳定性最差。新型骶髂拉力钉能有效修复骶髂关节损伤。结论 骶髂新型骶髂拉力钉能更有效地把持松质骨,具有一定的临床实用性。  相似文献   

18.
目的 探讨导针钝头探通法辅助判断空心拉力螺钉置入深度在老年患者股骨颈骨折闭合复位内固定术中应用的效果。方法 回顾性研究。纳入2016年10月—2020年10月河北医科大学第三医院创伤急救老年骨科收治的老年股骨颈骨折患者16例,其中男3例、女13例,年龄65~89(70.1±4.8)岁。患者均为GardenⅡ型骨折。均行闭合复位空心拉力螺钉内固定手术治疗,术中均使用导针钝头探通法辅助判断空心拉力螺钉置入深度。术后即刻复查患侧髋关节CT及三维重建,观察骨折断端对位、对线情况,螺钉的置入位置,测量螺钉尖与股骨头软骨下骨的距离,评估导针钝头探通法辅助判断螺钉深度技术的效果及有效性。术后1年内定期随访,观察切口愈合情况、骨折愈合时间以及内固定断裂、骨折不愈合等并发症的发生情况。术后6个月采用Harris评分评定疗效。结果 16例患者均顺利完成手术治疗,手术时间为30~85(51.8±11.2) min,术中出血量为20~100(44.3±23.5) mL。16例患者共打入空心拉力螺钉49枚,术后即刻影像学检查显示,骨折断端对位、对线优良,螺钉的置入位置良好,螺钉钉尖与股骨头软骨下骨的距离为0.21~0.49 (0.38±0.11) cm;螺钉置入位置均有效,有效性为优(100%)。术后患者伤口均一期愈合,未发生感染、内固定失败。16例患者均获随访,随访时间6~16(9.1±3.3)个月。随访期间无螺钉断钉、退钉及股骨头塌陷、坏死等并发症发生,骨折愈合时间为3~6(4.1±1.0)个月。术后6个月采用Harris评分评定疗效,16例患者疗效均为优良。结论 在老年股骨颈骨折闭合复位内固定术中,使用导针钝头探通法辅助判断空心拉力螺钉置入深度,可将螺钉尖准确放置在股骨头软骨下骨下方0.5 cm范围内,有助于提高内固定稳定性、促进骨折断端良好愈合。  相似文献   

19.

Purpose

Presence of a cephalomedullary nail (CMN) in the medullary canal has been thought as advantageous in the control of femoral neck shortening (FNS) and lag screw sliding in trochanteric fracture compared to extramedullary fixation system. However, researches on the factors that influence the degree of FNS after cephalomedullary nailing are lacking.

Materials and Methods

We observed 95 patients (mean age, 75±2.8 years) with trochanteric fractures who were treated with a CMN, and evaluated the relationship between FNS and patient factors including age, gender, fracture type (AO/OTA), bone mineral density, medullary canal diameter, canal occupancy ratio (COR=nail size/canal diameter), and tip-apex distance using initial, immediate postoperative, and follow-up radiography.

Results

Univariate regression analyses revealed that the degree of FNS was significantly correlated with fracture type (A1 versus A3, p<0.001), medullary canal diameter (p<0.001), and COR (p<0.001). Multiple regression analyses revealed that FNS was strongly correlated with fracture type (p<0.001) and COR (p<0.001).

Conclusion

Presence of a CMN in the medullary canal could not effectively prevent FNS in patients with low COR and in A3 type fracture.  相似文献   

20.
Research on embodied cognition suggests the ubiquity of embodiment effects during interaction with the environment. However, construal level theory (CLT) holds that these effects could be moderated by the psychological distance between self and objects and are attenuated by higher‐level mental construal. The current research explored the “action‐evaluation” embodiment effect in the evaluation of words located at different spatial distances. Results showed that for “short‐distance” words, the response model conflicted with this embodiment effect slower reaction time and induced a larger P2 component than the opposite response model. However, evaluation of “long‐distance” words was not significantly influenced by the response model. The results are consistent with CLT and suggest that the action‐evaluation embodiment effect influences the coding and execution of evaluating actions, but only for stimuli at close psychological distance locations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号