1.
目的 观察滤波反投影法(FBP)、二维有序子集最大期望值法(2D-OSEM)及其参数对SPECT颞颌关节显像髁突代谢活性的影响。方法 回顾性分析197例因单侧髁突异常增生致偏颌畸形患者,分别以2D-OSEM及FBP算法对SPECT重建图像,前者子集数为2、4、8,迭代次数为4、8、16,后者应用巴特沃斯滤波器,设定截止频率为0.32,阶数为9。基于重建图像分别计算双侧髁突摄取百分率差值,评估髁突代谢活性;观察FBP和2D-OSEM算法子集数及迭代次数对双侧髁突摄取百分率差值及髁突代谢活性阳性率的影响。结果 双侧髁突摄取百分率差值在子集数为2、迭代次数为4的2D-OSEM重建图像中与FBP重建图像中的差异无统计学意义(Z=-1.86,P=0.06),而在其余2D-OSEM图像中均高于FBP图像(P均<0.01)。子集数(F=16.85,P<0.01)及迭代次数(F=34.29,P<0.01)对2D-OSEM重建图像中的双侧髁突摄取百分率差值存在显著主效应,且其间存在交互效应(F=13.14,P<0.01),双侧髁突摄取百分率差值随子集数或迭代次数增加而增高。2D-OSEM (142/197,72.08%)与FBP (88/197,44.67%)重建图像的髁突代谢活性总阳性率差异有统计学意义(χ2=30.91,P<0.01)。2D-OSEM重建图像中,子集数为4时,髁突代谢活性阳性率的平均值为53.80%,与子集数为2(50.93%)及8时(57.87%)差异均无统计学意义(χ2=0.98、1.98,P=0.32、0.16);子集数为8时,髁突代谢活性阳性率平均值高于子集数为2时(χ2=5.74,P=0.02);迭代次数为8时,髁突代谢活性阳性率的平均值为53.81%,与迭代次数为4(51.10%)及16(57.70%)时差异均无统计学意义(χ2=0.87、1.82,P=0.35、0.18);迭代次数为16时,髁突代谢活性阳性率的平均值高于迭代次数为4时(χ2=5.19,P=0.02)。结论 采用FBP或2D-OSEM算法及不同参数行SPECT颞颌关节显像重建,髁突代谢活性存在差异。  相似文献   

2.
目的 观察Karl迭代重建技术对低剂量CT定量评估婴幼儿肺密度及肺容积的影响。方法 纳入100例临床疑诊呼吸系统疾病的婴幼儿,将其随机分为低剂量(LD)组及常规剂量(RD)组各50例;采集肺部平扫CT图像,对LD组分别以滤波反投影(FBP)算法及Karl 1、3、5、7、9级迭代重建技术重建图像,对RD组以FBP算法重建。记录2组有效剂量(ED),测量并比较各重建图像中的全肺平均肺密度(MLD)和全肺容积(LV)的差异,以及支气管分叉水平的主动脉、竖脊肌、胸腺、前胸壁皮下脂肪噪声值(SD)平均值及图像质量主观评价的差异。结果 LD组ED较RD组下降84.44%。FBP重建图像中,LD组MLD和主观评分均低于RD组(P均<0.01),其LV和SD均高于RD组(P均<0.01)。LD组内Karl 1、3、5、7、9级重建图像中的MLD、LV、SD和主观评分差异均有统计学意义(P均<0.05);随Karl迭代等级升高,MLD逐渐升高、LV和SD则逐渐减低,Karl 7级与Karl 1级间各指标差异均有统计学意义(P均<0.05),主观评分以Karl 5级最高。LD组Karl 5级重建图像的MLD和主观评分均高于LD组FBP重建图像(P均<0.05)而低于RD组FBP重建图像(P<0.05);LV和SD均低于LD组FBP重建图像(P均<0.01),而高于RD组FBP重建图像(P<0.01)。结论 低剂量定量CT可能低估婴幼儿MLD而高估其LV;Karl迭代重建技术能提高CT定量分析的准确性、降低图像噪声、提高图像质量,尤以Karl 5级迭代重建图像质量最佳。  相似文献   

3.
目的 探讨重建算法对SPECT断层成像分辨力的影响。方法 采用Siemens Symbia T SPECT机,对长轴分布5条线源的椭圆柱分辨力模型进行成像。选择Hann和Butterworth 2种滤波反投影法(FBP),每种窗函数各选择3种截止频率;Flash 3D和有序子集最大期望值(OSEM)法2种迭代法,各选择5种平滑函数;分别对图像进行断层重建。以线源半高宽(FWHM)代表重建图像的分辨力,计算5条线源6个层面上的径向、切向和轴向FWHM,并行多元线性回归分析。结果 FBP重建中,FWHM随窗函数截止频率增大而变小;同一截止频率下,Butterworth重建图像的FWHM小于Hann。迭代法中,FWHM随平滑函数核宽度增大而变大;Flash 3D和OSEM法重建图像径向及切向FWHM差异无统计学意义,而轴向Flash 3D图像的FWHM显著小于OSEM。结论 重建算法及参数设定对断层图像分辨力的影响较大,应根据临床需要和经验适当选择。  相似文献   

4.
目的 探讨低剂量扫描与低浓度对比剂联合迭代重建技术对颈部血管模型CTA检查的应用价值。方法 建立9个颈部血管模型,CT扫描采用管电压120 kV、管电流250 mAs,分别进行滤波反投影(FBP)重建和iDose3、iDose4、iDose5重建。采用不同管电压(80、100 kV)和管电流(200、250、300、350 mAs)进行两两组合扫描,进行iDose5重建。对图像质量和辐射剂量进行评价,并进行统计学分析。结果 120 kV 250 mAs图像iDose5重建的CNR优于FBP重建 (P<0.05)。不同扫描条件的iDose5重建图像与120 kV 250 mAs FBP重建图像的CNR和SNR差异均有统计学意义(P均<0.05),噪声差异均无统计学意义(P均>0.05)。与120 kV 250 mAs FBP重建图像比较,80 kV 200 mAs iDose5重建图像的CNR差异有统计学意义(P<0.05);80 kV 200 mAs iDose5、80 kV 250 mAs iDose5、100 kV 350 mAs iDose5重建图像的SNR差异均有统计学意义(P均<0.05)。余扫描条件和重建方法图像的CNR、SNR两两比较,差异均无统计学意义(P均>0.05)。管电压不变时,iDose5重建的容积CT剂量指数(CTDIvol)、剂量长度乘积(DLP)、有效剂量(ED)随管电流的增加而增加;管电流不变时,iDose5重建的CTDIvol、DLP、ED随管电压的增加而增加。结论 低剂量扫描与低浓度对比剂联合迭代重建技术可获得高质量的CTA图像,且能够减低辐射剂量。  相似文献   

5.
目的 评价胸部CT扫描中迭代去金属伪影算法(IMAR)减少金属伪影的有效性。方法 采用仿真胸部体模(仿真体模组),在T5椎体两侧各植入1枚椎弓根螺钉。以130 kV管电压和自动毫安秒(care dose 4D)技术,在植入螺钉前后行胸部CT扫描。对无金属图像进行滤波反投影(FBP)算法重建,对有金属螺钉的图像分别采用FBP算法和IMAR重建,选取螺钉邻近层面的主动脉、肺、椎旁软组织为ROI,测量噪声值和CT值,并计算CT值相对于无金属植入物图像CT值的偏移程度(ΔHU)。另回顾性分析我院26例接受胸部CT检查、且扫描范围内有椎弓根螺钉植入物的患者(病例组),扫描条件、图像重建方式参数同体模扫描,测量金属伪影邻近脊椎骨组织及背部软组织CT值,并由2名放射科医师分别对两种重建图像进行主观图像质量评价。结果 植入螺钉后,仿真体模组主动脉、肺、椎旁软组织IMAR重建图像的噪声值低于FBP重建图像(P均<0.05),IMAR重建的ΔHU明显小于FBP重建图像(P均<0.01)。病例组FBP重建和IMAR重建方式的脊椎骨组织CT值和背部软组织CT值差异均有统计学意义(P均<0.05)。对FBP重建和IMAR重建图像的主观评分差异有统计学意义(P<0.05)。结论 IMAR算法可明显减少条状伪影,并可校正受影响的组织CT值,使之更接近于无金属情况下的真实值。  相似文献   

6.
目的 探讨低管电流联合迭代重建算法对仿真胸部体模T12骨密度(BMD)的准确性和胸部图像质量的影响。方法 选用成年男性胸部体模,管电压120 kV,管电流分别为20、30、40、50、60 mAs,联合滤波反投影算法(FBP)、混合迭代重建技术(iDose4,Level 4)及迭代模型重建(IMR,Level 2)行胸部扫描。比较采用不同管电流和重建技术时胸部体模T12的BMD及客观评价结果;比较管电流20 mAs、采用IMR算法与管电流60 mAs、采用FBP迭代算法的纵隔窗和肺窗图像质量的主观评分,并评价观察者间的一致性。结果 管电流、重建技术不同时,胸部体模T12的BMD和CT值差异均无统计学意义(P均>0.05),而SD值差异有统计学意义(P均<0.001)。相同管电流下,采用IMR算法获得的SD值明显低于iDose4和FBP(P均<0.001)。管电流60 mAs、采用FBP算法时,2名观察者观察纵隔窗的一致性较好(Kappa=1,P<0.001),观察肺窗的一致性中等(Kappa=0.64,P=0.002);管电流20 mAs、采用IMR时,2名观察者观察纵隔窗的一致性中等(Kappa=0.64,P=0.002),观察肺窗的一致性较好(Kappa=1,P<0.001)。结论 低管电流联合迭代重建算法可降低辐射剂量,同时满足骨密度测值的准确性及胸部图像诊断。  相似文献   

7.
目的 探讨滤波反投影(FBP)、混合迭代重建(iDose4)和基于模型的迭代重建(IMR)技术对低剂量双下肢CTA图像质量的影响。方法 对56例成年患者行双下肢CTA扫描,分别用FBP、iDose4和IMR方法重建,测量下肢各段血管(腹主动脉分叉处、髂总动脉分叉处、股动脉近端、股动脉中段和腘动脉近端)的CT值、图像噪声及对比噪声比(CNR),并采用4分法对3组图像质量分别进行主观评分。结果 FBP、iDose4和IMR重建图像的下肢各段血管平均CT值分别为(511.07±195.05)HU、(492.63±178.74)HU、(487.63±197.20)HU,三者间差异无统计学意义(F=1.175,P>0.05)。图像噪声分别为(76.24±20.85)HU、(39.16±11.75)HU、(13.09±2.55)HU,三者间差异有统计学意义(F=1 460.000,P<0.05)。CNR分别为6.35±3.14、12.97±5.10、33.83±15.85,三者间差异有统计学意义(F=646.122,P<0.05)。图像质量主观评分IMR(3.75±0.46)、FBP(1.39±0.51)、iDose4(2.61±0.81)差异有统计学意义(χ2=476.79,P<0.05),膝关节以上、下段动脉可诊断率IMR(98.66%)明显高于FBP(1.34%)、iDose4(56.70%),差异均有统计学意义(χ2=427.9,P<0.05)。结论 行低辐射剂量双下肢CTA扫描时,相比FBP和iDose4,IMR可以显著降低图像噪声,提高图像质量,且能满足诊断要求。  相似文献   

8.
目的 采用CT容积扫描及三维重建等技术建立上气道模型,探讨儿童腺样体大小与鼻咽腔容积关系,分析阻塞性睡眠呼吸暂停低通气综合征(OSAHS)的影响。方法 采集109例儿童鼻咽部CT图像后进行重建,测量并计算腺样体大小(A/N值)及鼻咽腔容积等参数。根据A/N值将所有儿童分为正常组和肥大组,根据是否患有OSAHS分为OSAHS组和非OSAHS组。比较正常组和肥大组间各参数差异,分析不同性别及不同年龄A/N值与鼻咽腔容积的关系,以及OSAHS对A/N值与鼻咽腔容积关系的影响。结果 肥大组鼻咽腔容积[(3 111.67±1 304.73)mm3]小于正常组[(4 960.55±2 036.14)mm3P<0.01], A/N值(0.69±0.11)大于正常组(0.45±0.97,P<0.01)。男性及女性儿童鼻咽腔容积与A/N值均呈负相关(r=-0.43,r=-0.42,P均<0.01)。5岁以下儿童A/N值与鼻咽腔容积的相关性(r=-0.43)小于6~10岁儿童(r=-0.49),OSAHS组A/N值与鼻咽腔容积相关性(r=-0.60)高于非OSAHS组(r=-0.33)。结论 腺样体大小与鼻咽腔容积呈负相关且存在年龄差异。OSAHS患儿腺样体大小与鼻咽腔容积的相关性更高。  相似文献   

9.
目的 探讨自适应统计迭代重建(ASiR)算法在儿童头部CT扫描中的应用价值。方法 对1个水模进行CT扫描,管电压100 kV,管电流分别为200、180、160、140、120和100 mA,ASiR比例分别设置为0、10%、20%、30%、40%、50%,采用FBP和ASiR迭代重建两种重建算法进行图像重建,比较不同条件下图像CNR、SNR和图像噪声。将80例接受头部CT扫描的患儿分为对照组(n=40)和试验组(n=40)。对照组采用管电压100 kV、管电流200 mA,FBP重建算法进行图像重建;试验组采用管电压100 kV、管电流140 mA,分别采用FBP和ASiR两种重建法进行图像重建;将重建后的图像分别记为试验FBP亚组和试验ASiR亚组;对两组中图像的CNR、SNR、图像噪声、CTDIvol、DLP、ED进行比较。结果 水模研究中,采用ASiR(30%)、管电流140 mA、ASiR算法重建图像的SNR、CNR及空气噪声值与管电流 200 mA、FBP重建图像最为接近。对照组与试验ASiR亚组图像的图像噪声、灰白质CNR和灰质SNR值差异均无统计学意义(P均>0.05);对照组和试验ASiR亚组图像的噪声、灰质SNR、灰白质CNR均优于试验FBP亚组,且差异均有统计学意义(P均<0.001)。结论 采用ASiR重建算法的头部CT扫描,既可降低患儿接受的辐射剂量,又保证了图像质量,具有较高的临床应用价值。  相似文献   

10.
目的 目的探讨滤波反投影(FBP)、自适应统计迭代重建(ASiR)、能谱成像(85 keV)及呋塞米改良法在提高CT尿路造影(CTU)图像质量中的应用价值。方法 对40例患者常规CTU扫描后,采用能谱CT行排泄期扫描,常规扫描方式下排泄期图像分别利用FBP、ASiR 30%重建,能谱成像选择85 keV时的图像。对同期32例患者采用呋塞米改良法CTU成像,采用FBP法重建。根据不同的扫描模式和重建算法,分为传统FBP组、传统ASiR组、能谱组和改良组。观察并分析4组图像,测量并比较硬化性伪影明显层面肾盏旁硬化性伪影和输尿管连续性评分及肾脏的噪声、SNR、CNR。结果 传统FBP组、传统ASiR组和能谱组患者输尿管连续性评分差异无统计学意义(χ2=3.42,P=0.49),改良组输尿管连续性评分明显优于传统FBP组(χ2=24.30,P<0.05)。4组肾盏旁硬化性伪影评分、噪声、SNR、CNR比较差异均有统计学意义(P均<0.01),且传统ASiR组、能谱组、改良组肾盏旁硬化性伪影评分两两比较差异均有统计学意义(P均<0.05),组间两两比较SD、SNR、CNR差异均有统计学意义(P均<0.05)。与传统FBP组噪声比较,传统ASiR组降低约16.00%,能谱组降低约51.13%,改良组降低约27.11%;与传统FBP组SNR比较,传统ASiR组增加约21.11%,能谱组增加约42.01%,改良组增加约77.31%;与传统FBP组CNR相比,传统ASiR组增加约21.01%,能谱组增加约39.00%,改良组增加约53.02%。结论 改良法降低CTU硬化伪影效果最佳,其次为能谱成像(85 keV)。能谱CTU降低噪声效果最佳,其次为改良法及ASiR。改良法对输尿管连续性显影效果最好。  相似文献   

11.
BackgroundThe aim of this study was to validate the quantitative accuracy of single photon emission computed tomography with computed tomography (SPECT/CT) images in cardiac phantom studies. The study was performed by assessing the effect of resolution recovery (RR) when using half-time of imaging acquisition in cardiac phantom.MethodsThe SPECT/CT images of the anthropomorphic phantom with a cardiac insert, liver, lung, and spine were acquired using the GE Discovery (NM/CT 670) SPECT/CT system. Different concentration activity ratios for different organ (10:10:1:0, cardiac:liver:background:lung) regions were acquired by using full- and half-time protocols for 643 and 1283 voxel sizes that were reconstructed using filtered back projection (FBP) method and 3D ordered subset expectation maximization (3D-OSEM). Attenuation correction and scatter correction were applied to both reconstructions, whereas the RR only can be applied for 3D-OSEM. The data were analyzed and reported in terms of absolute recovery coefficient percentage between the cardiac insert and background activity concentration. Another parameter used to assess the quantitative accuracy for defect region was the relative error percentage.ResultsThe result of recovery coefficient percentage shows that the 3D-OSEM reconstruction with the RR gives the highest percentage estimation accuracy of 70% of activity recovery in the cardiac phantom wall compared with FBP (10.6%). The relative error percentage for reconstructed SPECT/CT images using 3D-OSEM reconstruction with RR shows the least error compared with FBP (21% vs. 45.1%) both in the full-and half-time acquisition of images with a larger number of matrix size used.Conclusions3D-OSEM reconstruction with the RR is beneficial in giving better quantitative evaluation with a good resolution myocardial perfusion image. To accomplish this, a larger matrix size is required for 3D-OSEM reconstruction with the RR and it demonstrated an improvement in image resolution and increased quantitative accuracy of the final reconstructed SPECT/CT images.  相似文献   

12.
223Radium dichloride image-based individual dosimetry requires an optimal acquisition and reconstruction protocol and proper image correction methods for theranostic applications. To assess this problem, radium-223 dichloride SPECT images were acquired from a Jaszczak simulator with a dual-headed gamma camera, LEHR collimator, 128 × 128 matrix, and total time of 32 minutes. A cylindrical PMMA phantom was used to calibrate the measurements performed with Jaszczak. The image quality parameters (noise coefficient, contrast, contrast-to-noise ratio and recovery coefficient) and septal penetration correction were calculated by MATLAB®. The best results for the investigated image quality parameters were obtained with an 89 keV energy window (24% wide) produced together with OSEM/MLEM reconstruction (8 subsets and 4 iterations) applying a Butterworth filter (order 10 and cutoff frequency of 0.48 cycles·cm?1). The successfully performed recovery coefficient parameter evaluation allows uptake correction for future patient dosimetry applications.  相似文献   

13.
Iterative reconstructions are increasingly used for clinical PET studies owing to the better noise properties compared with filtered backprojection (FBP). The purpose of the present study was to compare ordered subsets expectation maximization (OSEM) iterative reconstruction with FBP as input for statistical parametric mapping (SPM) analysis of PET activation studies. Two phantom studies were performed simulating both motor and cognitive tasks and acquiring data with both high and low statistics. In contrast to clinical studies, where no a priori information is known, phantom studies allow for an accurate and detailed comparison between different reconstruction techniques. The significance of "activations" during "tasks" was determined using SPM99 software. Using region of interest analysis of SPM results, it was found that the maximum and average t values within each hot spot of the phantom were higher for OSEM than for FBP. In addition, OSEM4 x 16 (4 iterations, 16 subsets) produced fewer false-positive voxels than FBP, OSEM1 x 16 and OSEM2 x 16. In conclusion, for PET activation studies use of OSEM4 x 16 seems to give the best tradeoff between signal detection and noise reduction.  相似文献   

14.
目的 观察不同重建条件组合对不同大小病灶图像质量的影响,提出一体化PET/MR对于小病灶的最佳图像重建方案。方法 采用GE SIGNA TOF PET/MR系统对符合国际电工协会(IEC)推荐标准的PET图像质量(IQ)发射体模进行扫描,并对列表模式PET原始数据按照以下条件分别组合进行重建:有序子集最大期望值(迭代子集:28;迭代次数:1~9次);重建矩阵(128×128,192×192,256×256);高斯低通滤波器,半高宽(FWHM)(1~6 mm);单独使用飞行时间(TOF)技术;单独使用点扩散函数(PSF);同时使用TOF和PSF(TOF+PSF);不使用TOF和PSF(NOTOF+NOPSF)。分析不同重建条件下图像对比度恢复(CR)、背景变化率(BV)和信噪比(SNR),评估图像质量。结果 10 mm和13 mm小球在OSEM(3次迭代,28个子集)、192×192矩阵、2 mm高斯滤波半高宽、TOF+PSF重建组合下信噪比最高,分别为13.31%、21.73%,13.31%、21.73%,25.74%、35.80%和26.25%、46.01%。结论 3次迭代、28个子集、192×192矩阵、TOF+PSF为本研究条件下一体化PET/MR对于模拟小病灶的最佳图像重建方案。  相似文献   

15.
目的 比较自适应统计迭代重建(ASIR)、常规基于模型的迭代重建(MBIRc)、新一代基于模型的迭代重建(MBIRn)中优化低密度对比设置的MBIRNR403种算法对低剂量上腹部CT图像质量的影响。方法 采用CT扫描静止状态下水模,比较0.625 mm层厚时滤波反投影算法(FBP)、ASIR、MBIRc和MBIRNR40的空间分辨率和密度分辨率。1年内接受2次腹部增强CT扫描受检者60例,初次检查采用常规辐射剂量(噪声指数=10)扫描,FBP重建。复查时采用低辐射剂量方案(噪声指数=20)扫描,分别采用标准算法ASIR、MBIRc和MBIRNR40三种方法重建为0.625 mm层厚的图像后进行对比分析。测量皮下脂肪、背部肌肉、肝脾实质CT值和噪声,计算以皮下脂肪为背景的肝脾实质CNR,采用单因素方差分析比较各重建算法噪声和CNR。由2名放射科医师以常规剂量FBP重建为基础,采用半定量目测评分法盲法进行噪声和细节结构、病变边缘清晰度评分,比较主观评分差异,评价观察者间一致性。结果 体模研究提示MBIRc空间分辨率最高,MBIRNR40密度分辨率最高。临床研究显示初次检查剂量长度乘积(DLP)为(368.03±146.25) mGy·cm,有效剂量(ED)为(5.52±2.19) mSv;复查时DLP为(93.18±41.21) mGy.cm,ED为(1.40±0.62) mSv,分别下降约74.68%和74.64%。MBIRNR40重建图像肌肉、脂肪噪声低于MBIRc、ASIR重建和常规剂量FBP重建(P均<0.05)。MBIRNR40重建图像肝脾CNR大于MBIRc、ASIR重建和常规剂量FBP重建(P均<0.05)。2名放射科医师主观评分一致性优良。低剂量MBIRNR40主观图像噪声最低、显示上腹部细节结构和病变边缘特征最清晰,优于MBIRc,MBIRc优于常规剂量FBP,低剂量ASIR最差,差异均有统计学意义(P均<0.05)。结论 减少辐射剂量约75%低剂量上腹部成像时,MBIR重建图像质量优于ASIR、MBIRc重建图像及常规剂量FBP图像。  相似文献   

16.
目的 利用仿真胸部体模,比较原始数据域迭代重建(SAFIRE)算法与滤波反投影(FBP)算法对胸部CT图像质量和辐射剂量的影响。方法 在新双源CT(Somatom definition flash CT)设备上预设80、100、120 kV三组管电压值,采用自动毫安秒care dose 4D技术对仿真胸部体模进行扫描,分别用FBP及SAFIRE重建算法(等级1~5)重建图像,比较胸部不同组织结构的噪声及CT值,并由2名放射科医师独立评价图像质量。每组扫描结束后,记录CT剂量加权指数(CTDIvol)和剂量长度乘积(DLP),计算并比较有效剂量。结果 相同扫描参数检查时,SAFIRE重建算法较FBP算法图像噪声明显降低(P<0.05);不同扫描参数检查时,无论FBP算法或SAFIRE重建算法,图像噪声均随管电压增加而降低;胸部各组织结构的噪声会随重建算法和管电压改变而发生变化;100 kV/SAFIRE(等级3)的主观和客观图像质量指标均优于120 kV/FBP,且辐射剂量降低37.61%。结论 胸部CT扫描中,采用SAFIRE重建算法能有效提高图像质量,降低辐射剂量。  相似文献   