首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   11篇
  免费   1篇
基础医学   4篇
临床医学   1篇
神经病学   1篇
特种医学   2篇
外科学   1篇
眼科学   1篇
药学   1篇
肿瘤学   1篇
  2022年   1篇
  2018年   1篇
  2016年   1篇
  2015年   1篇
  2012年   2篇
  2011年   1篇
  2010年   2篇
  2007年   1篇
  2002年   1篇
  1999年   1篇
排序方式: 共有12条查询结果,搜索用时 19 毫秒
1.
2.
Graefe's Archive for Clinical and Experimental Ophthalmology - Ferromagnetic foreign bodies (FFB) present during magnetic resonance imaging (MRI) explorations can lead to tissue injury due to...  相似文献   
3.
Selective internal radiation therapy (SIRT) using Yttrium-90 loaded glass microspheres injected in the hepatic artery is an emerging, minimally invasive therapy of liver cancer. A personalized intervention can lead to high concentration dose in the tumor, while sparing the surrounding parenchyma. We propose a computational model for patient-specific simulation of entire hepatic arterial tree, based on liver, tumors, and arteries segmentation on patient’s tomography. Segmentation of hepatic arteries down to a diameter of 0.5 mm is semi-automatically performed on 3D cone-beam CT angiography. The liver and tumors are extracted from CT-scan at portal phase by an active surface method. Once the images are registered through an automatic multimodal registration, extracted data are used to initialize a numerical model simulating liver vascular network. The model creates successive bifurcations from given principal vessels, observing Poiseuille’s and matter conservation laws. Simulations provide a coherent reconstruction of global hepatic arterial tree until vessel diameter of 0.05 mm. Microspheres distribution under simple hypotheses is also quantified, depending on injection site. The patient-specific character of this model may allow a personalized numerical approximation of microspheres final distribution, opening the way to clinical optimization of catheter placement for tumor targeting.  相似文献   
4.
It is a major challenge to guarantee homogeneous acquisition during a prospective multicenter magnetic resonance imaging (MRI) study that makes use of different devices. The goal of the multicenter Grand Ouest Glioblastoma Project (GOGP) was to correlate MRI quantitative parameters with biological markers extracted from image-guided biopsies. Therefore, it was essential to ensure spatial coherence of the parameters as well as the signal intensity and homogeneity. The project included the same MRI protocol implemented on six devices from different manufacturers. The key point was the initial acceptance of the imaging devices and protocol sequences. For this purpose, and to allow comparison of quantitative patient data, we propose a specific method for quality assessment. A common quality control based on 10 parameters was established. Three pulse sequences of the clinical project protocol were applied using three test-objects. A fourth test-object was used to assess T1 accuracy. Although geometry-related parameters, signal-to-noise ratio, uniformity, and T1 measurements varied slightly depending on the different devices, they nevertheless remained within the recommendations and expectations of the multicenter project. This kind of quality control procedure should be undertaken as a prerequisite to any multicenter clinical project involving quantitative MRI and comparison of data acquisitions with quantitative biological image-guided biopsies.  相似文献   
5.
The authors sketch their personal recollections of Isabel Menzies Lyth and the various roles in which they knew her, in particular, as a group relations consultant and as an organizational development consultant. They describe Isabel's contribution to the fields of group relations and consultancy and her critical views of the use of unmodified psychoanalytical models and her innovative ways of working. The authors make the point that Isabel never departed from her scientific research and change-oriented consultancy roots; they describe how she strove to move people and organizations on; they also describe how her most powerful tool lay in holding the balance between the content of groups and organizations and the processes of researching, listening and consulting and her expert use of the transference and countertransference.  相似文献   
6.
Natural killer cell function is controlled by interaction of NK receptors with MHC I molecules expressed on target cells. We describe the binding of bacterially expressed Ly49A, the prototype murine NK inhibitory receptor, to similarly engineered H-2Dd. Despite its homology to C-type lectins, Ly49A binds independently of carbohydrate and Ca2+ and shows specificity for MHC I but not bound peptide. The affinity of the Ly49A/H-2Dd interaction as determined by surface plasmon resonance is from 6 to 26 microM at 25 degrees C and is greater by ultracentrifugation at 4 degrees C. Biotinylated Ly49A stains H-2Dd-expressing cells. Competition experiments indicate that the Ly49A and T cell receptor (TCR) binding sites on MHC I are distinct, suggesting complex regulation of cells that bear both TCR and NK cell receptors.  相似文献   
7.

BACKGROUND AND PURPOSE

Pentoxifylline is in clinical trials for non-alcoholic fatty liver disease and diabetic nephropathy. Metabolic and hepatic effects of pentoxifylline were assessed in a murine model of obesity and type 2 diabetes.

EXPERIMENTAL APPROACH

Pentoxifylline (100 mg·kg−1·day−1) was administered for 4 days or 3 weeks in lean and obese/diabetic ob/ob mice. Plasma lipids, glucose, other metabolites and relevant enzymes were measured by standard assays. Hepatic lipids in vivo were assessed with magnetic resonance spectroscopy and by histology. Hepatic extracts were also analysed with RT-PCR and Western blotting.

KEY RESULTS

Four days of pentoxifylline treatment slightly increased liver lipids in ob/ob mice. After 3 weeks, pentoxifylline exacerbated fatty liver and plasma transaminases in ob/ob mice but did not induce liver steatosis in lean mice. Plasma glucose was highest in fed, but not fasted, ob/ob mice treated with pentoxifylline. During the first 10 min of an oral glucose tolerance test, blood glucose increased more rapidly in pentoxifylline-treated mice. Jejunal expression of glucose transporter 2 isoform was increased in pentoxifylline-treated obese mice. Hepatic activity of carbohydrate response element binding protein (ChREBP) increased after pentoxifylline in ob/ob, but not lean, mice. Hepatic expression of lipogenic enzymes was highest in pentoxifylline-treated ob/ob mice. However, pentoxifylline reduced markers of oxidative stress and inflammation in ob/ob liver.

CONCLUSION AND IMPLICATIONS

Pentoxifylline exacerbated fatty liver in ob/ob mice through enhanced intestinal glucose absorption, increased postprandial glycaemia and activation of hepatic lipogenesis. Long-term treatment with pentoxifylline could worsen fatty liver in some patients with pre-existing hyperglycaemia.  相似文献   
8.
Two cases of pulmonary oedema during beta 2-adrenergic agonist therapy in pre-eclampsia pregnant patients are reported. In our first case, the pulmonary oedema was exceptionally severe, because the patient (twins at 26 SA) had to be intubated and ventilated, but the caesarean section was performed only 6 weeks later. These two clinical observations underline the fact that B2 adrenergic agonist are not indicated for the treatment of preeclampsy. Furthermore they suggest that such patients should be rapidly admitted to intensive care units.  相似文献   
9.
Errors in the flip angle have to be corrected in many magnetic resonance imaging applications, especially for T1 quantification. However, the existing methods of B1 mapping fail to measure lower values of the flip angle despite the fact that these are extensively used in dynamic acquisition and 3D imaging. In this study, the nonlinearity of the radiofrequency (RF) transmit chain, especially for very low flip angles, is investigated and a simple method is proposed to accurately determine both the gain of the RF transmitter and the B1 field map for low flip angles. The method makes use of the spoiled gradient echo sequence with long repetition time (TR), such as applied in the double-angle method. It uses an image acquired with a flip angle of 90° as a reference image that is robust to B1 inhomogeneity. The ratio of the image at flip angle alpha to the image at a flip angle of 90° enables us to calculate the actual value of alpha. This study was carried out at 1.5 and 4.7 T, showing that the linearity of the RF supply system is highly dependent on the hardware. The method proposed here allows us to measure the flip angle from 1° to 60° with a maximal uncertainty of 10% and to correct T1 maps based on the variable flip angle method.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号