首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   72篇
  免费   1篇
临床医学   3篇
内科学   66篇
外科学   4篇
  2023年   1篇
  2022年   2篇
  2021年   3篇
  2018年   3篇
  2017年   2篇
  2015年   1篇
  2013年   2篇
  2012年   11篇
  2011年   6篇
  2010年   3篇
  2009年   4篇
  2008年   4篇
  2007年   4篇
  2006年   3篇
  2005年   4篇
  2004年   5篇
  2003年   6篇
  2002年   8篇
  2001年   1篇
排序方式: 共有73条查询结果,搜索用时 78 毫秒
1.
2.
BACKGROUND: Biphasic rectilinear shocks are more effective than monophasic shocks for transthoracic atrial defibrillation and for ventricular arrhythmias during electrophysiological testing.We undertook the present study to compare the efficacy of 100 J rectilinear biphasic waveform shocks with 150 J monophasic damped sine waveform shocks for transthoracic defibrillation of true ventricular fibrillation during defibrillation threshold testing (DFT).The second aim of the study was to analyse the influence of patch positions on the efficacy of defibrillation. METHODS: 50 episodes of 14 patients (age ranging from 37 to 82 years) who underwent DFT testing were randomised for back-up shocks with either a sequence of 100 and 200 J biphasic waveform, or a sequence of 150 and 360 J conventional monophasic shocks. A binary search protocol was used at implantation and before hospital discharge. Patients were also randomised to an anteroposterior position versus a right-anterior-apical position. A crossover was performed between implantation and pre-hospital discharge for biphasic versus monophasic sequence as well as for the 2 different positions. RESULTS: After failed internal shocks, 27 episodes were treated with biphasic, and 23 with monophasic shocks.The first attempt by the external device did not terminate II episodes (2 biphasic, 9 monophasic).The first shock efficacy was significantly greater with biphasic than with monophasic shocks (p < 0.02).The overall success rate was 93% with biphasic shocks and 64% with monophasic shocks. In multivariate regression analysis including patch position, arrhythmia duration, type of waveform, testing order and session, only waveform was associated with successful defibrillation (p < 0.02). CONCLUSION: For transthoracic defibrillation of ventricular fibrillation, low-energy rectilinear biphasic shocks are more effective than monophasic shocks.The position of the defibrillation shock pads has no influence on the biphasic shock efficacy, but anteroposterior pad position is more effective using monophasic shocks.  相似文献   
3.

Introduction

Although macroreentrant atrial tachycardia (MRAT) and focal atrial tachycardia (FAT) can be successfully cured by catheter ablation, the proper diagnosis and treatment of these arrhythmias can still be challenging.

Aim

The objective of this study is to develop an algorithm allowing rapid diagnosis of the mechanism and the chamber of origin of atrial tachycardia based on intracardiac catheter recordings from the right atrium and the coronary sinus (CS).

Methods

A 2-stepped algorithm was designed: (1) The time of biatrial activation expressed as a percentage of the tachycardia cycle length served to discriminate FAT from MRAT. (2) In FAT, the direction of activation of the CS catheter and the earliest atrial activation were used to define the chamber of origin. In MRAT, the time of right atrium activation was determined or entrainment was used at different sites. Thirty-two intracardiac recordings were reviewed off-line after the algorithm by 4 electrophysiologists blinded to the mechanism and the chamber of origin. The results of their analysis were compared with the intraoperative diagnosis.

Results

The algorithm correctly identified 11 (100%) of 11 FATs and 19 (90.4%) of 21 MRATs. The site of origin was correctly identified in 8 (72.7%) of 11 FATs and in 20 of 21 (95.2%) MRATs. The site of origin was misidentified in 3 FATs, all arising from the CS ostium.

Conclusions

This algorithm allows rapid discrimination between FAT and MRAT. The chamber of origin is detected with a high accuracy in MRAT. However, the earliest atrial activation taken as an isolated event is not a good predictor for the chamber of origin in FAT arising from the ostium of the CS.  相似文献   
4.
AIM: Cryothermal energy has the ability reversibly to demonstrate loss of function with cooling, ice mapping, at less deep temperatures. The purpose of this study was to investigate the time course of the temperature during ice mapping of accessory pathways. METHODS AND RESULTS: Thirteen patients with the Wolff-Parkinson-White (WPW) syndrome underwent cryoablation. After identification of a prospective ablation site, ice mapping was performed by cooling the tip to a minimum of -30 degrees C. Successful ice mapping was defined by loss of accessory pathway (AP) conduction. A total of 104 ice maps were analyzed. Successful ice mapping was demonstrated in 17 attempts. There was no significant difference in mapping temperature between successful and unsuccessful ice mapping (-29.4+/-3.2 degrees Celsius vs -30.4+/-1.7 degrees Celsius). The temperature time constant tau during successful ice mapping was significantly shorter compared with unsuccessful ice mapping (7.0+/-1.1 s vs 10.1+/-1.3 s; P<0.0001). The response time (RT) to mapping temperature of -30 degrees C was significantly prolonged in unsuccessful ice mapping attempts (35.8+/-4.5 s vs 53.5+/-11.0 s; P<0.0001). Significant correlations were found between successful ice mapping and the temperature time constant, and between RT and the temperature time constant (P<0.001). CONCLUSION: The ability to identify prospective ablation sites by ice mapping was demonstrated. Successful ice mapping attempts were characterized by a short temperature time constant and a short response time to mapping temperature with a sudden disappearance of pathway conduction.  相似文献   
5.
Current guidelines have indicated an implantable cardioverter-defibrillator (ICD) for patients with severe idiopathic dilated cardiomyopathy, for both primary and secondary prevention. Compared to coronary artery disease, the overall benefit has been smaller. A more refined risk assessment, using the left ventricular ejection fraction (LVEF) and prevention mode (primary/secondary), is still needed to guide ICD implantation. Patients included in 2 large ICD registers were analyzed regarding the appropriate therapies and improvement of LVEF, overall and in subgroups of prevention mode and LVEF < 20% versus > 20%. Overall, 349 patients were included; 70% were men, the mean age was 54 years, and the mean follow-up was 33 months. Cardiac resynchronization therapy (CRT) was used in 57%, and secondary prevention was present in 30%. ICD therapies were delivered to 33% of the patients, in most for ventricular tachycardia. Patients receiving an ICD for secondary prevention and non-CRT were more likely to have arrhythmic events (both p < 0.05). The cumulative event rates at 5 years were 53% for secondary and 33% for primary prevention (p < 0.001). Depending on the prevention mode and LVEF status (< 20% vs > 20%), the event rates ranged from 30% to 76%. The mean LVEF improved by 10%, independently of the stimulation mode (CRT 22% to 31%, non-CRT 26% to 35%; p < 0.0001). A persistent improvement to > 35% was seen in only 25% of CRT patients but in 45% of non-CRT patients (p = 0.004). In conclusion, the results from the present study have demonstrated that in patients with idiopathic dilated cardiomyopathy, the potential for LVEF improvement is considerable and that the rate of ICD interventions strongly depends on the prevention mode and LVEF. These findings could be the basis for additional risk stratification tools.  相似文献   
6.
Remote Magnetic Navigation for VT Ablation. Background: This study aimed to compare acute and late outcomes of VT ablation using the magnetic navigation system (MNS) to manual techniques (MAN) in patients with (SHD) and without (NSHD) structural heart disease. Methods: Ablation data of 113 consecutive patients (43 SHD, 70 NSHD) with ventricular tachycardia treated with catheter ablation at our center were analyzed. Success rate, complications, procedure, fluoroscopy, and ablation times, and recurrence rates were systematically recorded for all patients. Results: A total of 72 patients were included in the MNS group and 41 patients were included in the MAN group. Patient age, gender, and right ventricular and left ventricular VT were equally distributed. Acute success was achieved in 59 patients in the MNS group (82%) versus 27 (66%) patients in the MAN group (P = 0.046). Overall procedural time (177 ± 79 vs 232 ± 99 minutes, P < 0.01) and mean patient fluoroscopy time (27 ± 19 vs 56 ± 32 minutes, P < 0.001) were all significantly lower using MNS. In NSHD pts, higher acute success was achieved with MNS (83,7% vs 61.9%, P = 0.049), with shorter procedure times (151 ± 57 vs 210 ± 96, P = 0.011), whereas in SHD‐VT these were not significantly different. No major complications occurred in the MNS group (0%) versus 1 cardiac tamponade and 1 significantly damaged ICD lead in the MAN group (4.9%, NS). After follow‐up (20 ± 11 vs 20 ± 10 months, NS), VT recurred in 14 pts (23.7%) in the MNS group versus 12 pts (44.4%) in the MAN group (P = 0.047). Conclusions: The use of MNS offers advantages for ablation of NSHD‐VT, while it offers similar efficacy for SHD‐VT. ((J Cardiovasc Electrophysiol, Vol. 23, pp. 948‐954, September 2012)  相似文献   
7.
8.
9.
AIMS: Fluoroscopy does not allow identification specific anatomical landmarks during electrophysiological studies. Intra-cardiac echocardiography permits visualization of these structures with excellent accuracy, but the optimal method has not been fully described. The aim of this study was to assess the capability of intra-cardiac echocardiography for the visualization of such structures using two different approaches. We also assessed its capability for the evaluation of radio frequency lesions 20 min after catheter ablation of the cavo-tricuspid isthmus. METHODS: Intra-cardiac echocardiography was performed using a 9 MHz rotating transducer in eight consecutive patients (age range: 37-76 years) after radio frequency ablation of the cavo-tricuspid isthmus. The ultrasound catheter was inserted through the femoral vein into the superior vena cava and was pulled back to the inferior vena cava. The echo catheter was then reinserted through the subclavian vein and advanced into the right ventricular apex and was pulled back from the right ventricular to the superior vena cava. Qualitative evaluation and intra-cardiac measurements were performed off-line. RESULTS: The fossa ovalis, the tricuspid valve, and the terminal crest were visible in all patients regardless of the method of introduction of the echo catheter. Left-sided structures were less accurately seen by intra-cardiac echocardiography. The horizontal diameter of the fossa ovalis was 8.9+/-1.8mm. The cavo-tricuspid isthmus was visible using the femoral approach in three patients. The isthmus could be visualized in all patients, and in three patients together with the ostium of the coronary sinus, using the subclavian approach. radio frequency lesions were not visible 20 min after ablation. Additionally, both the left and right ventricles could be seen using the subclavian approach. CONCLUSIONS: The subclavian approach is feasible, safe and superior to visualize the isthmus. Twenty minutes after radio frequency ablation of the cavo-tricuspid isthmus radio frequency lesions are not visible using intra-cardiac echocardiography.  相似文献   
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号