目的探讨8周基础军训(basic military training,BMT)对入伍新兵血像中红细胞及其相关指标的影响,为指导科学的军事训练提供参考。方法数据来自新疆边防部队2015年度入伍的50名男性新兵,分别在BMT前后测定并记录受试新兵的红细胞计数、血红蛋白浓度及血清铁蛋白等。结果经过8周的BMT,新兵血液中血红蛋白浓度、红细胞计数及血清铁蛋白均显著下降(P0.05,P0.01)。结论 8周BMT可能导致入伍新兵发生运动性贫血,铁缺乏可能是其主要原因。 相似文献
Rotary ventricular assist devices (VADs) are less sensitive to preload than the healthy heart, resulting in inadequate flow regulation in response to changes in patient cardiac demand. Starling‐like physiological controllers (SLCs) have been developed to automatically regulate VAD flow based on ventricular preload. An SLC consists of a cardiac response curve (CRC) which imposes a nonlinear relationship between VAD flow and ventricular preload, and a venous return line (VRL) which determines the return path of the controller. This study investigates the importance of a physiological VRL in SLC of dual rotary blood pumps for biventricular support. Two experiments were conducted on a physical mock circulation loop (MCL); the first compared an SLC with an angled physiological VRL (SLC‐P) against an SLC with a vertical VRL (SLC‐V). The second experiment quantified the benefit of a dynamic VRL, represented by a series of specific VRLs, which could adapt to different circulatory states including changes in pulmonary (PVR) and systemic (SVR) vascular resistance versus a fixed physiological VRL which was calculated at rest. In both sets of experiments, the transient controller responses were evaluated through reductions in preload caused by the removal of fluid from the MCL. The SLC‐P produced no overshoot or oscillations following step changes in preload, whereas SLC‐V produced 0.4 L/min (12.5%) overshoot for both left and right VADs. Additionally, the SLC‐V had increased settling time and reduced controller stability as evidenced by transient controller oscillations. The transient results comparing the specific and standard VRLs demonstrated that specific VRL rise times were improved by between 1.2 and 4.7 s ( = 3.05 s), while specific VRL settling times were improved by between 2.8 and 16.1 seconds ( = 8.38 s) over the standard VRL. This suggests only a minor improvement in controller response time from a dynamic VRL compared to the fixed VRL. These results indicate that the use of a fixed physiologically representative VRL is adequate over a wide variety of physiological conditions. 相似文献
Context: We sought to describe our experience with the Hybrid Assistive Limb® (HAL®) for active knee extension and voluntary ambulation with remaining muscle activity in a patient with complete paraplegia after spinal cord injury.
Findings: A 30-year-old man with complete paraplegia used the HAL® for 1 month (10 sessions) using his remaining muscle activity, including hip flexor and upper limb activity. Electromyography was used to evaluate muscle activity of the gluteus maximus, tensor fascia lata, quadriceps femoris, and hamstring muscles in synchronization with the Vicon motion capture system. A HAL® session included a knee extension session with the hip flexor and voluntary gait with upper limb activity. After using the HAL® for one month, the patient’s manual muscle hip flexor scores improved from 1/5 to 2/5 for the right and from 2/5 to 3/5 for the left knee, and from 0/5 to 1/5 for the extension of both knees.
Conclusion/clinical relevance: Knee extension sessions with HAL®, and hip flexor and upper-limb-triggered HAL® ambulation seem a safe and feasible option in a patient with complete paraplegia due to spinal cord injury. 相似文献
Etomidate is frequently selected over propofol for induction of anaesthesia because of a putatively favourable haemodynamic profile, but data confirming this perception are limited.
Methods
Patients undergoing cardiac surgery were randomised to induction of anaesthesia with propofol or etomidate. Phase I (n=75) was conducted as open-label, whereas Phase II (n=75) was double blind. Mean arterial blood pressure (MAP) and boluses of vasopressor administered after induction were recorded. The primary endpoint was the area under the curve below baseline MAP (MAP-time integral) during the 10 min after induction. Secondary endpoints were the use of vasopressors over the same period, and the effect of blinding on the aforementioned endpoints. Groups were compared using regression models with phase and anaesthetist as factors.
Results
The mean difference between etomidate and propofol in the MAP-time integral below baseline was 2244 mm Hg s (95% confidence interval, 581–3906; P=0.009), representing a 34% greater reduction with propofol. Overall, vasopressors were used in 10/75 patients in the etomidate group vs 21/75 in the propofol group (P=0.38), and in 20/74 patients during the blinded phase vs 11/76 during the open-label phase (P=0.31). The interaction between randomisation and phase (open-labelled or blinded) was not significant for either primary (P=0.73) or secondary endpoints (P=0.90).
Conclusions
Propofol caused a 34% greater reduction in MAP-time integral from baseline after induction of anaesthesia than etomidate, despite more frequent use of vasopressors with propofol, confirming the superior haemodynamic profile of etomidate in this context. The proportion of patients receiving vasopressors increased slightly, albeit not significantly, in both groups in the blinded phase.
Clinical trial registration
Australian and New Zealand Clinical Trials Registry, ACTRN12614000717651. 相似文献