Cutaneous wound pain causes physical and psychological stress for patients with wounds. Previous studies reported that stress induces hyperalgesia and deteriorates wound healing. However, the effect of the stress response such as in hypothalamic‐pituitary‐adrenal (HPA) axis on local wound area is unclear. We aimed to investigate the effects of a stress response on the mechanical withdrawal threshold in the local wound area and describe the identification of a wound pain exacerbation. We topically injected adrenocorticotropic hormone (ACTH) into the granulation tissue of full‐thickness cutaneous wound model rats on the fifth day postwounding and measured the mechanical withdrawal thresholds, cytochrome P450 2Bs levels and concentration of 5,6‐epoxyeicosatrienoic acid in wound exudate. We found that ACTH induced mechanical hypersensitivity at 4 and 6 hours after injection (P = .004 and .021, respectively), and increased gene expression of cytochrome P450 2B12 expression (P = .046). Concentration of 5,6‐EET in the wound exudate was moderately correlated with the mechanical withdrawal threshold (r = ?.630). Finally, the mechanical withdrawal threshold in the 5,6‐EET group was significantly lower than that in the control group at 2 hours after the injection (P = .015). We propose that 5,6‐EET is one of the most promising contributors to the wound pain exacerbation. These findings could guide clinical wound and pain management. 相似文献
The structural properties, elastic anisotropy, electronic structures and work function of D022-type Al3TM (TM = Sc, Ti, V, Y, Zr, Nb, La, Hf, Ta) are studied using the first-principles calculations. The results indicate that the obtained formation enthalpy and cohesive energy of these compounds are in accordance with the other calculated values. It is found that the Al3Zr is the most thermodynamic stable compound. The mechanical property indexes, such as elastic constants, bulk modulus, shear modulus, Young’s modulus, Poisson’s ratio, and Vickers hardness are systematically explored. Moreover, the calculated universal anisotropic index, percent anisotropy and shear anisotropic factors of D022-type Al3TM are analyzed carefully. It demonstrates that the shear modulus anisotropy of Al3La is the strongest, while that of Al3Ta is the weakest. In particular, the density of states at Fermi level is not zero, suggesting that these phases have metal properties and electrical conductivity. More importantly, the mechanisms of correlation between hardness and Young’s modulus are further explained by the work function. Finally, the experimental design proves that D022-Al3Ta has an excellent strengthening effect. 相似文献
Purpose: Orthodontic tooth movement occurs during the bone remodeling induced by therapeutic mechanical strain. It is important to investigate the relation between the strength of mechanical stress and bone formation activity. The aim of this study was to determine the effect of high-magnitude mechanical strain on bone formation in detail.Materials and methods: Osteoblast-like cells isolated from fetal rat calvariae were loaded with 18% cyclic tension force (TF) for 48?h. To phenotypically investigate the effect of TF, we measured the number and the size of bone nodules stained by von Kossa technique on day 21 after cell seeding and determined the calcium content of bone nodules on day 14. Furthermore, we examined the gene expression of BMP-2, Runx2 and Msx2, which are important factors for bone nodule formation, on days 1, 4 and 7 after TF loading.Results: The maximum bone nodule size in the control group was 1620 and 719?μm in the TF group. Furthermore, the mean number of bone nodules sized over 360?μm in the TF group was significantly decreased compared to the control group. The calcium content was also significantly decreased to 42% by TF loading. The mRNA expression of BMP-2, Runx2 and Msx2 was decreased 1 and 4 days after TF loading.Conclusion: The differentiation of bone forming progenitor cells into bone nodule forming cells was inhibited by TF due to the decreased expression of bone formation related factors such as BMP-2, Runx2 and Msx2. 相似文献
BackgroundDespite numerous advances in the implant design and surgical technique, improvement in patient satisfaction following total knee arthroplasty (TKA) has plateaued. Various TKA alignment strategies have been introduced that impact the coronal positioning of the tibial component relative to the native joint line. This study aims to analyze if postoperative variance of the joint line from preoperative native alignment is correlated with changes in patient-reported outcomes following primary TKA.MethodsA retrospective review of an academic center’s patient population identified all primary TKAs between 2013 and 2021 with full-length, standing radiographs and patient-reported outcome measures (PROMs) data. These measures included the Knee injury and Osteoarthritis Outcome Score for Joint Replacement, Patient-Reported Outcome Measurement Information System, and Veterans RAND 12 scores. Preoperative and postoperative radiographic measurements for hip-knee angle, tibia-metaphyseal angle, tibial-axis orientation angle, and joint-line obliquity angle were recorded. Three-month, 1-year, and 2-year PROM scores were correlated with the change in degrees for each of the angles using a Spearman’s correlation. A Mann-Whitney U-test was used to compare angular changes with a change in PROM scores.ResultsOne hundred and ninety nine patients (204 knees) with a mean age of 67 years were included. Average follow-up was 23 months. Three-month, 1-year, and 2-year follow-up rates were 93%, 64%, and 34%, respectively. Improvements were seen across all PROMs regardless of an angular change.ConclusionThere were no clear correlations between PROMs and variation in joint line obliquity in the coronal plane. These data suggest that the magnitude of the variation in coronal tibial alignment from native alignment does not impact PROMs. Further study is indicated to correlate an angular change with functional measures. 相似文献
Objective: To report a case of labour induction during extracorporeal membrane oxygenation (ECMO) support in a patient with acute respiratory distress syndrome (ARDS) caused by influenza and review of the literature.
Methods: Case report and the literature search of all English articles on delivery while on ECMO in patients with ARDS caused by influenza.
Results: A 25-year-old pregnant woman was initiated with ECMO due to severe ARDS caused by influenza A (H1N1) virus. When the patient had symptoms of colporrhagia and uterine contractions, the medical team decided to start labour induction while on ECMO. There were in total five case reports identified. Maternal oxygenation was improved after delivery and ECMO was successfully discontinued.
Conclusions: Maternal oxygenation was improved after delivery, which may be beneficial to reduce the duration of ECMO. Caesarean section (CS) may be the most used mode and labour induction could be another option. The procedure should be performed by an experienced ECMO team, cooperating with the obstetrician, anaesthesiologist, and ICU doctors. 相似文献