BackgroundIn patients with melanoma, sentinel lymph node (SLN) status is pivotal for treatment decisions. Current routine for SLN detection combines Technetium99m (Tc99) lymphoscintigraphy and blue dye (BD). The primary aim of this study was to examine the feasibility of using a low dose of superparamagnetic iron oxide (SPIO) injected intracutaneously to detect and identify the SLN, and the secondary aim was to investigate if a low dose of SPIO would enable a preoperative MRI-evaluation of SLN status.MethodsPatients with melanoma of the extremities were eligible. Before surgery, a baseline MRI of the nodal basin was followed by an injection of a low dose (0.02–0.5 mL) of SPIO and then a second MRI (SPIO-MRI). Tc99 and BD was used in parallel and all nodes with a superparamagnetic and/or radioactive signal were harvested and analyzed.ResultsFifteen patients were included and the SLNB procedure was successful in all patients (27 SLNs removed). All superparamagnetic SLNs were visualized by MRI corresponding to the same nodes on scintigraphy. Micrometastatic deposits were identified in four SLNs taken from three patients, and SPIO-MRI correctly predicted two of the metastases. There was an association between MRI artefacts in the lymph node and the dose SPIO given.DiscussionIt is feasible to detect SLN in patients with melanoma using a low dose of SPIO injected intracutaneously compared with the standard dual technique. A low dose of SPIO reduces the lymph node MRI artefacts, opening up for a non-invasive assessment of SLN status in patients with cancer. 相似文献
BackgroundA venous leg ulcer is a chronic leg wound caused by poor venous blood circulation in the lower limbs. It is a recurring condition causing pain, malodour, reduced mobility, and depression. Randomised controlled trials evaluating treatments for venous leg ulcers provide important evidence to inform clinical decision-making. However, for findings to be useful, outcomes need to be clinically meaningful, consistently reported across trials, and fully reported. Research has identified the large number of outcomes reported in venous leg ulcer trials, impacting both synthesis of results, and clinical decision-making. To address this, a core outcome set will be developed. A core outcome set is an agreed standardised set of outcomes which should be, as a minimum, measured and reported in all trials which evaluate treatment effectiveness for a given indication. A core outcome set has the potential to reduce research waste, improve the utility of RCTs, reduce reporting bias, facilitate treatment comparisons across different sources of evidence and expedite the production of systematic reviews, meta-analyses and evidence-based clinical guidelines.AimThe aim of this project is to develop a core outcome set for research evaluating the effectiveness of interventions for treating venous leg ulceration.MethodsThrough a scoping review of the literature on venous leg ulceration, we will firstly identify a list of candidate outcome domains (broad categories in relation to what is being measured) from randomised controlled trials and qualitative research, and outcomes (specific methods in relation to what is being measured). In two further stages, we will use the resulting lists of outcome domains and outcomes to design two online surveys. A range of stakeholders will be invited to participate in the surveys and they will be asked to indicate which outcome domains and outcomes are most important and should be considered as core in future research reports. 相似文献
BackgroundThe growing enthusiasm for the use of reverse shoulder arthroplasty (RSA) in the treatment of primary glenohumeral osteoarthritis (GHOA) with an intact rotator cuff is based on data derived from single-center studies with limited generalizability and follow-up. This study compared patient-reported outcomes (PROs) between RSA and total shoulder arthroplasty (TSA) for the treatment of primary GHOA with up to 5-year follow-up and examined temporal trends in the treatment of GHOA between 2012 and 2021.MethodsA retrospective review was performed on patients with primary GHOA undergoing primary arthroplasty surgery from the Surgical Outcomes System global registry between 2012 and 2021. PROs including the American Shoulder and Elbow Surgeons (ASES) score, Single Assessment Numeric Evaluation (SANE) score, and visual analog scale (VAS) for pain were compared between RSA and TSA at 1, 2, and 5 years postoperatively.ResultsA total of 4451 patients were included, with 2693 (60.5%) undergoing TSA and 1758 (39.5%) undergoing RSA. Both RSA and TSA provided clinically excellent outcomes at 1 year postoperatively (ASES: 80.8 ± 17.9 vs. 85.9 ± 15.2, respectively; SANE: 74.8 ± 24.7 vs. 79.5 ± 22.9; VAS pain: 1.3 ± 2.0 vs. 1.1 ± 1.7; all P < .05) that were maintained at 2 years (ASES: 81.3 ± 19.3 vs. 87.3 ± 14.9; SANE: 74.8 ± 26.2 vs. 79.7 ± 24.7; VAS pain: 1.3 ± 2.1 vs. 1.0 ± 1.6; all P < .05) and 5 years (ASES: 81.7 ± 16.5 vs. 86.9 ± 15.3; SANE: 71.6 ± 28.5 vs. 78.2 ± 25.9; VAS pain: 1.0 ± 1.7 vs. 1.0 ± 1.7; all P < .05), with statistical significance favoring TSA. After controlling for age and sex, there was an adjusted difference of 4.5 units in the ASES score favoring TSA (P = .005) at 5 years postoperatively but no differences in adjusted SANE (P = .745) and VAS pain (P = .332) scores. The use of RSA for GHOA grew considerably over time, from representing only 17% of all replacements performed for GHOA in 2012 to nearly half (47%) in 2021 (P < .001).ConclusionRSA as a treatment for GHOA with an intact rotator cuff seems to yield PROs that are largely clinically equivalent to TSA extending to 5 years postoperatively. The observed statistical significance favoring TSA appears to be of marginal clinical benefit based on established minimal clinically important differences and may be a result of the large sample size. Further research using more granular clinical data and examining differences in range of motion and complications is warranted as it may change the value analysis. 相似文献
This study evaluated the genetic variation of 17 autosomal short tandem repeat (STR) loci included in the PowerPlex® 18D Kit. Samples of 562 unrelated healthy Lahu individuals living in Yunnan Province in southwestern China were investigated. The data were analyzed to provide information on allele frequencies and other statistical parameters relevant to the forensic population. Of the 17 loci, 16 reached the Hardy–Weinberg equilibrium after Bonferroni correction. A total of 176 alleles were identified in 17 STR loci, and allele frequencies ranged from 0.000 890 to 0.578 292. The combined discrimination power (CPD) and probability of excluding paternity (CPE) of the 17 STR loci were 0.999 999 999 999 999 999 489 and 0.999 998 301 753 122. The genetic relationships among 28 populations were also estimated. 相似文献
Introduction: Ocular dysfunctions and toxicities induced by antiepileptic drugs (AEDs) are rarely reviewed and not frequently received attention by treating physicians compared to other adverse effects (e.g. endocrinologic, cognitive and metabolic). However, some are frequent and progressive even in therapeutic concentrations or result in permanent blindness. Although some adverse effects are non-specific, others are related to the specific pharmacodynamics of the drug.
Areas covered: This review was written after detailed search in PubMed, EMBASE, ISI web, SciELO, Scopus, and Cochrane Central Register databases (from 1970 to 2019). It summarized the reported ophthalmologic adverse effects of the currently available AEDs; their risks and possible pathogenic mechanisms. They include ocular motility dysfunctions, retinopathy, maculopathy, glaucoma, myopia, optic neuropathy, and impaired retinal vascular autoregulation. In general, ophthalmo-neuro- or retino-toxic adverse effects of AEDs are classified as type A (dose-dependent), type B (host-dependent or idiosyncratic) or type C which is due to the cumulative effect from long-term use.
Expert opinion: Ocular adverse effects of AEDs are rarely reviewed although some are frequent or may result in permanent blindness. Increasing knowledge of their incidence and improving understanding of their risks and pathogenic mechanisms are crucial for monitoring, prevention, and management of patients’ at risk. 相似文献
Zygomatic implant treatment is widely applied for severe maxillary atrophy to help rehabilitate the maxillary dentition. This retrospective study was performed to evaluate the actual radiographic bone–implant contact (rBIC) lengths of zygomatic implants. The records of 28 patients who underwent zygomatic implant surgery and subsequent follow-up examinations between August 2013 and September 2018 in the Department of Oral and Maxillofacial Surgery, Taipei Tzu Chi Hospital were reviewed. The surgeries were performed by a single surgeon using the same treatment protocol. All patients had a computed tomography scan at 1 year after the surgery. Using three-dimensional imaging software, an investigator measured the rBIC lengths of 66 implants and documented their clinical status. The implant survival rate was 100%. The mean rBIC length was significantly longer in male patients than in female patients (20.80 ± 5.88 mm versus 17.79 ± 6.34 mm; P = 0.028). The mean rBIC length of double zygomatic implants was significantly longer when compared to that of single implants (21.11 ± 6.23 mm versus 17.75 ± 5.85 mm; P = 0.027). This article is novel in reporting the exact rBIC lengths of zygomatic implants in a clinical setting. The results showed that zygomatic implants are a viable treatment modality for full-mouth rehabilitation. 相似文献
IntroductionSelection of optimal image acquisition protocols in medical imaging remains a grey area, the superimposed use of the Likert scale in radiological image quality evaluations creates an additional challenge for the statistical analysis of image quality data.Using a simulation study, we have trialled a novel approach to analysing radiological image quality Likert scale data.MethodsA simulation study was undertaken where simulated datasets were generated based on the distribution of Likert scale values according to varying image acquisition protocols from a real dataset. Simulated Likert scale values were pooled in four different ways; the mean, median, mode and the summation of patient Likert scale values of which the total was assigned a categorical Likert scale value. Estimates of bias, MAPE and RMSPE were then calculated for all four pooling approaches to determine which method most accurately represented an expert's opinion.ResultsWhen compared to an expert's opinion, the method of summation and categorisation of Likert scale values was most accurate 49 times out of the 114 (43.0%) tests. The mean 28 times out of 114 (24.6%), the median 23 times out of 114 (20.2%) and the mode 17 times out of 114 (14.9%).ConclusionWe conclude that our method of summation and categorisation of Likert scale values is most often the best representation of the simulated data compared to the expert's opinion.Implications for practiceThere is scope to reproduce this simulation study with multiple observers to reflect clinical reality more accurately with the dynamic nature of multiple observers. This also prompts future investigation into other anatomical areas, to see if the same methods produce similar results. 相似文献