首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 468 毫秒
1.
目的 探讨玻璃体切除术治疗儿童外伤性眼内炎的疗效.方法 回顾性研究,17例(17眼)儿童外伤性眼内炎治疗方法及疗效.结果 单纯玻璃体腔注药控制4眼;玻璃体切除13眼,其中玻璃体、晶状体切除联合硅油填充10眼,玻璃体切除联合硅油填充2眼,眼内注气1眼;17眼中共保留晶状体5眼.9眼视力提高(52.94%),视力不变者3眼(17.65%),视力下降5眼(29.41%)(其中3眼眼球萎缩).结论 儿童外伤性眼内炎手术效果与眼内炎程度、就诊时间、致病菌毒力有关,无外伤性白内障的眼内炎玻璃体切除是否保留晶状体要考虑年龄及眼内炎的严重程度.  相似文献   

2.
林育华  招志毅 《国际眼科杂志》2010,10(10):1882-1884
目的:观察玻璃体腔注射蛇毒降纤酶和万古霉素对外伤性增生性玻璃体视网膜病变(proliferative vitreoretinopathy,PVR)的抑制效果.方法:新西兰白兔40只右眼建立外伤性出血性眼球穿通伤动物模型.左眼为空白对照眼.随机分为4组,生理盐水组10眼,玻璃体腔注射生理盐水0.1mL;蛇毒降纤酶组10眼,玻璃体腔注射蛇毒降纤酶0.1U(0.1mL);万古霉素组10眼,玻璃体腔注射万古霉素1mg(0.1mL);联合用药10眼,玻璃体腔分别注射蛇毒降纤酶0.1 U及万古霉素1mg.通过裂隙灯显微镜观察眼前节炎症情况,眼前节炎症持续超过2wk以上者行玻璃体腔微生物学培养;直接眼底镜观察玻璃体出血指数、外伤性PVR情况.结果:联合用药组玻璃体出血指数低于生理盐水组(P<0.01)、外伤性PVR程度低于生理盐水组(P<0.01);联合用药组玻璃体出血指数低于万古霉素组(P<0.05)、外伤性PVR程度低于万古霉素组(P<0.01);生理盐水组、蛇毒降纤酶组各发生细菌性眼内炎3例(30%);万古霉素组、联合用药组未见细菌性眼内炎的发生.结论:在外伤性出血性眼球穿通伤动物模型中,玻璃体腔注射蛇毒降纤酶和万古霉素可能可以促进玻璃体腔出血的吸收、降低外伤性PVR程度和减低感染性眼内炎症发生率.  相似文献   

3.
目的:探讨外伤性眼内炎不同处理方法的临床效果。方法:回顾性系列病例研究。选择沧州市中心医院2010年11月至2016年7月收治的外伤性眼内炎患者73例(73眼),其中41眼急诊行玻璃体切割术,32 眼急诊单纯行玻璃体腔注药术。玻璃体切割手术者中21 眼硅油填充,9 眼20% C3F8 填充,11 眼行单纯玻璃体切割术,玻璃体切割手术开始时及玻璃体腔注药前均抽取玻璃体液送细菌培养及药敏试验,真菌培养及药敏试验。结果:患者随访6~24 个月,行硅油填充术后2 眼眼球萎缩,玻璃体腔注药效果不佳改玻璃体切割联合硅油填充术者中1眼最终眼球萎缩,除这3眼外,其余患者眼内炎症均得到控制。眼内取材培养阳性的患者共58 眼,其中混合感染5 眼。共培养致病菌63 株。致病菌谱的构成中,革兰氏阳性菌(62%)所占比例最大,其次为真菌(21%)和革兰氏阴性菌(18%)。从具体菌种看,表皮葡萄球菌为最常见的致病菌(25%),然后依次是曲霉菌(14%)和金黄色葡萄球菌(11%)。结论:对于外伤性眼内炎,一旦确诊,需根据病情即刻采取治疗措施,其中玻璃体切割术以及玻璃体腔注药术均为有效的治疗措施。  相似文献   

4.
目的:评价玻璃体切割联合眼内药物灌注治疗严重的外伤性眼内炎的临床效果.方法:回顾性分析30例(30眼)因外伤性眼内炎行玻璃体切除术,术中联合药物玻璃体腔灌注的患者.结果:术后 3mo 29 眼炎症得到控制,眼球得以保留,28眼视力有不同程度提高.眼内异物是最常见的受伤原因,金黄色葡萄球菌是最常见的细菌.结论:及时行玻璃体切割术联合眼内药物灌注是治疗外伤性眼内炎的有效方法.  相似文献   

5.
玻璃体切除手术治疗儿童外伤性眼内炎疗效观察   总被引:3,自引:2,他引:3  
目的:探讨玻璃体切除手术治疗儿童外伤性眼内炎的疗效。方法:回顾分析12例(12眼)儿童外伤性眼内炎经玻璃体切除术治疗的疗效。结果:玻璃体切除后12眼中10眼的炎症控制,另2眼二次手术玻璃体切除后炎症控制。1眼术后视网膜脱离行二次手术。随访2~21(平均8.7)mo。视力提高者9眼(75%),≥0.1者5眼(42%)。结论:玻璃体切除术联合敏感抗生素应用是治疗儿童外伤性眼内炎的有效手段。  相似文献   

6.
目的:研究玻璃体切除联合硅油填充手术治疗急性感染性眼内炎的临床效果。

方法:回顾性分析2008-01/2013-02我院收治的急性感染性眼内炎患者23例23眼临床资料,排除伴有球内异物的病例。所有患者均采用常规闭合三通道玻璃体切除联合硅油填充手术,其中6眼(并发外伤性白内障)联合Ⅰ期晶状体摘除+Ⅰ期人工晶状体植入术,3眼(并发外伤性白内障)联合Ⅰ期晶状体切除+Ⅱ期人工晶状体植入术, 4眼(硅油填充期间并发白内障)联合Ⅱ期晶状体摘除+Ⅱ期人工晶状体植入术,5眼(4眼外伤性眼内炎及1眼青光眼滤过泡漏致眼内炎)保留晶状体,1眼(白内障术后眼内炎)联合Ⅰ期人工晶状体取出+Ⅱ期人工晶状体植入,4眼(白内障术后眼内炎)保留人工晶状体。

结果:随访6~24mo,行玻璃体切除联合硅油填充手术的患者23例23眼眼内炎均得到有效控制,21眼(91%)患者视力不同程度提高。有2眼玻璃体切除术后眼压≥30mmHg,1眼行硅油取出术后眼压恢复正常,另1眼取硅油术后眼压仍高,需应用降眼压药物控制。

结论:急性感染性眼内炎患者及时行玻璃体切除联合硅油填充手术治疗,能有效控制眼内炎,提高患者视力。  相似文献   


7.
玻璃体切除玻璃体腔注药治疗感染性眼内炎   总被引:4,自引:1,他引:4  
目的评价玻璃体切除联合玻璃体腔注药治疗严重眼内炎的临床应用价值。方法对43例(43眼)感染性眼内炎进行玻璃体切除联合玻璃体腔注药、眼内异物摘出,或联合晶状体切除、视网膜脱离复位及硅油或惰性气体填充术,配合全身及局部应用抗生素(或抗真菌药)、皮质类固醇药物治疗。随访4月~4年。结果41眼(95.35%)眼内炎控制,保存了眼球;35眼(81.40%)视力不同程度的提高;视力无变化者3眼(6.98%);视力降低3眼(6.98%);1眼(2.33%)作眼内容摘除;1例术后自动出院,失随访。结论玻璃体切除联合玻璃体腔注药是治疗严重眼内炎的有效方法。  相似文献   

8.
目的 分析探讨外伤性眼内炎病原体的变化及治疗效果.方法 对2008年7月至2009年12月在我院就诊的122例126眼外伤性眼内炎的临床特点、外伤性质、病原体及治疗效果进行分析.结果 在外伤性眼内炎中,以细菌感染为主,真菌和混合性感染明显增加,玻璃体切除手术联合硅油注入及玻璃体腔注药后炎症得到控制,视力得到不同程度的提高,眼球摘除9眼.结论 外伤性眼内炎中真菌的比例明显增加,细菌的药物敏感性明显下降,玻璃体切除手术联合硅油填允及玻璃体腔注药术是治疗不同病原体引起的眼内炎的有效方法.  相似文献   

9.
目的 分析儿童外伤性眼内炎玻璃体切割手术后的治疗效果及影响因素。方法 对 1 7例(1 7眼 )儿童外伤性眼内炎的致伤原因、致伤物、性别、年龄、就诊时间、临床表现、治疗方式及效果进行回顾性分析。结果  1 7例患儿中因延迟就诊 ,病情进展为全眼球炎而行眼内容物剜除术 3例 ,1 4例急诊行玻璃体切割术。术后随访 3~ 6月 ,视力 0 3与 0 7各 1例 ,0 0 2~ 0 0 5者 3例 ,光感~0 0 2者 9例 ;玻璃体切割术后发生低眼压 4例 ,占 2 8 5 %。结论 儿童外伤性眼内炎玻璃体切割手术后治疗效果与眼内炎的程度、就诊是否及时、致病菌毒力大小有关。术后发生低眼压的原因可能与炎症形成睫状体膜、前部增生性玻璃体视网膜病变及硅油填充有关。  相似文献   

10.
玻璃体切割治疗复杂视网膜脱离45例临床分析   总被引:1,自引:1,他引:0  
目的:分析玻璃体切割术治疗复杂性视网膜脱离的效果。方法:对45例45眼复杂性视网膜脱离眼行闭合式玻璃体切割术,术毕玻璃体腔行C3F8气体或硅油填充。结果:玻璃体切割联合玻璃体腔注气术15眼,1次手术视网膜复位13眼(87%);玻璃体切割联合玻璃体腔内硅油填充术30眼,1次手术完全复位27眼(90%)。统计学检验两组1次手术视网膜复位率的差异无显著意义。术后视力:数指/眼前者2眼,0.02~0.05者3眼,0.06~0.1者10眼,0.12~0.25者19眼,≥0.3者11眼。术中常见的并发症有医源性视网膜裂孔,术后并发症最多见是继发性青光眼和白内障。结论:玻璃体切割联合眼内填充能有效地治疗复杂性视网膜脱离,术后大部分患者视力能得到改善。  相似文献   

11.
12.
13.
14.
15.
16.
The concentrations of Mg2+, K+ and Ca2+ in the intraocular fluids (IOFs) and blood plasma of chickens and pigeons were determined by atomic absorption spectrophotometry. The Mg2+ concentration in the IOFs of both species was greatest in the liquid vitreous adjacent to the retina followed by aqueous > blood plasma > plasma dialysate. In contrast the concentration of K+ in the IOFs of both chickens and pigeons was greater in the aqueous than in the liquid vitreous. The concentrations of Ca2+ in all IOF compartments of chicken eyes were virtually identical and were lower than that of blood plasma. The concentrations of Mg2+ in the IOFs of the chicken, especially in the liquid vitreous, was remarkably stable; experimentally lowering or raising the plasma Mg2+ concentration over a relatively wide range had little or no effect on the Mg2+ concentration in the IOFs of these animals. We can conclude that a high Mg2+ and low K+ concentration in the extracellular fluids of the retina is maintained in the avian eye, as in the mammalian eye, by active transport processes across the blood-retinal barrier systems. Because the avian retina is completely avascular, the site of these homeostatic transport processes must be the epithelium of the retinal choroid and/or the pecten. These findings support the concept that the contribution of the vitreous to the homeostasis of the retinal micro-environment is inversely related in vertebrates to the degree of retinal vascularization.  相似文献   

17.
ZusammenfassungZiel In dieser Studie soll die durch Flickerlicht verursachte Durchmesserreaktion retinaler Arterien und Venen hinsichtlich Ausmaß und zeitlichem Ablauf verglichen werden.Methoden In die klinische Studie wurden 26 gesunde Probanden einbezogen. Der Durchmesser der retinalen Gefäße jeweils eines Auges wurde kontinuierlich mittels eines Retinal vessel analyzer gemessen. Jede Untersuchung bestand aus 100 s Baseline sowie 5 Perioden von 20 s Flickerlichtstimulation, gefolgt von 80 s Beobachtung.Ergebnisse Unmittelbar nach Flickerlicht dilatierten die Arterien um 6,9±2,8% (MW±STD) und die Venen um 6,5±2,8% (Unterschied nicht signifikant). Der Quotient aus arterieller und venöser Dilatation (AVDQ) betrug 1,25±0,69 (Spannweite 0,2 bis 2,8). Es konnte keine signifikante Altersabhängigkeit der arteriellen bzw. venösen Dilatation oder des AVDQ nachgewiesen werden. Die arterielle Dilatation ging nach 25,9±10,8 s in eine leichte Konstriktion von –2,7±1,4% über. Im Gegensatz dazu waren die Venen zum Zeitpunkt des individuellen Konstriktionsmaximums noch um 0,5±1,3% dilatiert (p<0,001).Schlussfolgerungen Die flickerlichtinduzierte Durchmesserreaktion retinaler Arterien und Venen unterscheidet sich bei Gesunden nicht in ihrem mittleren dilatativen Maximum, aber in Form und zeitlichem Verlauf des Abklingens der Dilatation.Unterstützung durch: BMBF 13N7999.Vortrag gehalten auf der 101. Jahrestagung der DOG, Berlin, September 2003.  相似文献   

18.
19.
Acute multifocal placoid pigment epitheliopathy (AMPPE) has been associated with disease of the central nervous system. In this case report, we discuss a patient presenting with AMPPE in the setting of a new central nervous system association: cavernous sinus thrombosis.  相似文献   

20.
Olzak LA  Thomas JP 《Vision research》2003,43(13):1433-1442
Many current psychophysical models propose that visual processing in cortex is hierarchical, with nonlinearities sandwiched between linear stages of processing. In earlier publications, we proposed a model of this type to account for masking effects found with spatial frequency and orientation discriminations. Our model includes two nonlinear mechanisms that regulate contrast sensitivity in early cortical mechanisms. The first is a local within-pathway nonlinearity that accelerates at low contrasts but is compressive at high. The second is a pooled nonlinear gain control process that operates over a broad range of neurons with different tuning characteristics. Here, we test predictions of the model for spatial frequency discriminations. The model predicts that at low contrasts, adding a grating mask oriented parallel to test gratings will improve discrimination performance via operation of the within-pathway nonlinearity, analogous to the "dipper effect" found with contrast discriminations. Adding an orthogonally oriented mask is predicted to have no effect at low contrasts, where pooled gain control processes contribute little to performance. At high contrasts, the model predicts that performance will asymptote and become independent of contrast with either parallel or orthogonal masks. The results confirm model predictions.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号