首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 78 毫秒
1.
目的探讨骶骨骨巨细胞瘤的CT增强扫描特点及其在诊断中的应用价值.方法回顾分析60例骶骨肿瘤患者的CT增强扫描特点,依据病理结果,划分骨巨细胞瘤(实验组)与非骨巨细胞瘤(对照组)进行统计学分析,定量研究CT增强扫描后CT值的变化特征.结果在60例骶骨肿瘤中,骨巨细胞瘤22例,增强后强化最显著区域平均CT值为121.59±21.82HU;非骨巨细胞瘤38例,增强后强化最显著区域平均CT值为61.24±20.60HU;二者之间差异显著(P<0.05).ROC曲线分析表明,当CT值≥97HU时,诊断骨巨细胞瘤的敏感度为90.9%,特异性为99.97%.结论 CT增强扫描,CT值的定量分析在骶骨骨巨细胞瘤的定性诊断中有一定的导向价值.  相似文献   

2.
目的探讨MSCT增强扫描CT定量分析在骨巨细胞瘤的定性诊断中的应用价值。方法分别单独应用MSCT增强后强化CT值及强化CT值+年龄、部位和形态学特征等综合因素对我院329例溶骨性骨肿瘤或肿瘤样病变进行骨巨细胞瘤的前瞻性预判,分别划分骨巨细胞瘤组(实验组)与非骨巨细胞瘤组(对照组)进行统计学分析,定量研究CT增强扫描后CT值的变化特征,并追踪病理结果对照,最终有病理结果的186例中骨巨细胞瘤55例。结果在186例肿瘤或肿瘤样病变中,骨巨细胞瘤55例,增强后强化最显著区域平均CT值为(108±39)HU;非骨巨细胞瘤131例,增强后强化最显著区域平均CT值为(82±78)HU;二者差异有统计学意义(P<0.05)。当选取CT值临界点为97HU为标准进行预判时,诊断骨巨细胞瘤的敏感性为87.27%,特异性为78.62%,诊断正确率为81.18%;同时结合患者年龄及发病部位、形态特征等综合因素进行预判时,诊断骨巨细胞瘤诊断的敏感性为96.36%,特异性为96.18%,诊断准确率为96.23%。结论 CT增强扫描中CT值的定量分析在骨巨细胞瘤的定性诊断中有较好的导向价值,如果结合患者年龄及发病部位、形态学特征等综合因素进行预判,可以提高术前诊断正确率。  相似文献   

3.
目的:探讨多层螺旋CT三维重建后处理在肿瘤样病变中的鉴别诊断价值。方法:采用回顾性研究方法,选择2013年2月至2017年1月在我院进行诊治的肺部肿块患者235例作为研究对象,其中病理诊断为肿瘤样病变35例(肿瘤样病变组)和恶性肿瘤200例(肿瘤组),记录两组的多层螺旋CT特征与三维重建后处理灌注参数,判定诊断价值。结果:肿瘤样病变组的病灶最大径为(3.11±1.24) cm,增强幅值为(27.33±8.19) Hu;肿瘤组分别为(5.68±1.49) cm和(31.40±9.44) Hu,对比差异都有统计学意义(P<0.05)。肿瘤样病变组的病灶BV、BF与PS值分别为(2.84±1.93) ml·100 g-1、(2.14±1.33) ml·min-1·100 g-1和(12.89±5.29) ml·min-1·100 g-1,都明显低于肿瘤组病灶的(33.87±11.49) ml·100 g-1、(25.39±12.49) ml·min-1·100 g-1和(127.40±34.91) ml·min-1·100 g-1(P<0.05)。在235例患者中,CT判断为肿瘤样病变30例,恶性肿瘤205例,为此多层螺旋CT三维重建后处理在肿瘤样病变鉴别诊断中敏感性与特异性为100.0%和97.6%。结论:多层螺旋CT三维重建后处理在肿瘤样病变中的应用有很好的应用效果,能清楚显示病灶情况,能通过灌注参数进行病情判断,是鉴别肺部肿瘤样病变与恶性肿瘤的重要依据。  相似文献   

4.
叶慧  李杨  莫逸  谢爱民  彭翔 《陕西肿瘤医学》2011,(11):2293-2296
目的:评价18F-脱氧葡萄糖(18F-fluorodeoxyglucose,18F-FDG)PET/CT显像在肾上腺肿瘤诊断中的应用价值。方法:回顾性分析42例肾上腺肿瘤患者的全身18F-FDG PET/CT及CT平扫加增强的影像学资料,比较两者对肾上腺肿瘤的诊断价值。结果:42例中,原发性肾上腺肿瘤30例,均经手术病理证实。其余12例为转移性肾上腺肿瘤,肾癌转移4例,肺癌转移7例,肝癌转移1例。18F-FDG PET/CT检查阳性42例,敏感度100%,良性病变的SUV值为1.1-2.6,平均1.8,恶性病变的SUV值为2.5-12.3,平均6.0。良恶性病变的SUV值差异有统计学意义(P〈0.01)。CT平扫加增强检查阳性38例,敏感度90.5%。PET/CT对肾上腺肿瘤的敏感度明显高于CT,两者差异有统计学意义(P〈0.05)。结论:18F-FDG PET/CT在肾上腺肿瘤诊断中具有重要价值,敏感度高于CT。  相似文献   

5.
目的:检测埃兹蛋白(Ezrin)在骨巨细胞瘤组织中的表达,探讨其临床意义。方法将本院2008年1月至2013年12月穿刺活检确诊的60例骨巨细胞瘤设为观察组,同期8例良性病变中的反应性新生骨、12例骨样骨瘤及11例骨母细胞瘤的瘤组织作为对照组,用 Western blotting 及实时 PCR 方法检测 Ezrin 蛋白及基因水平。60例骨巨细胞瘤患者接受瘤段切除加假体置换术,术前均接受2个疗程的化疗,观察化疗前后瘤组织线粒体形态的变化以及 Ezrin 蛋白和基因的变化。结果骨巨细胞瘤中Ezrin 蛋白阳性表达主要位于细胞质中,表达阳性率为76.7%,远高于良性病变中反应性新生骨的19.7%、骨样骨瘤的21.2%以及骨母细胞瘤的20.7%,差异有统计学意义(χ2=4.18,P =0.024),良性病变中的反应性新生骨组、骨样骨瘤及骨母细胞瘤之间的 Ezrin 表达差异并无统计学意义(χ2=6.18, P =0.087)。化疗后骨巨细胞瘤组织中线粒体固缩及液态空泡现象较治疗前减少,Ezrin 蛋白表达减少,基因水平降低[(23.99±1.49):(20.11±1.11),t =5.03,P =0.018)]。结论 Ezrin 在骨巨细胞瘤的表达较其他良性骨肿瘤高,可能成为鉴别良恶性骨肿瘤的辅助生物学指标;对 Ezrin 的早期干预可能有助于骨巨细胞瘤的治疗。  相似文献   

6.
目的:评价多层螺旋CT(multi-slice spiral CT,MSCT)扫描对不典型肾上腺嗜铬细胞瘤的诊断价值。方法回顾性分析30例经手术病理证实的肾上腺嗜铬细胞瘤病例,其中有典型临床表现22例,无典型临床表现8例。对两组MSCT图像进行对比分析。结果8例不典型肾上腺嗜铬细胞瘤中肿块最大长径为(6.94±2.38)cm,变性7例;肿瘤实质成分平扫、动脉期和门脉期平均CT值分别为43.5 HU (35.7~51.5 HU)、95.2 HU(80.5~120.2 HU)和89.0 HU(75.7~103.8 HU)。22例典型肾上腺嗜铬细胞瘤中肿块最大长径为(6.34±1.35)cm,变性22例;肿瘤实质成分平扫、动脉期和门脉期平均CT值分别为43.0 HU(34.3~52.6 HU)、97.9 HU(78.3~122.8 HU)、90.2 HU(75.5~105.2 HU)。不典型肾上腺嗜铬细胞瘤与典型肾上腺嗜铬细胞瘤比较在肿块最大长径、变性比例以及肿瘤强化程度方面差异均无统计学意义(均P>0.05)。结论典型与不典型肾上腺嗜铬细胞瘤的MSCT表现具有一致性。  相似文献   

7.
目的:探讨16排螺旋CT诊断胃癌淋巴结转移的可行性与价值。方法:选取2011年7月至2014年7月在我院进行诊治的胃癌患者78例,16排螺旋CT进行诊断,并进行常规CT扫描与增强CT灌注扫描。结果:78例患者中有淋巴结转移60例,无淋巴结转移18例,淋巴结转移发生率为76.9%。无转移淋巴结组的肿瘤直径为(0.54±0.11)cm,而有淋巴结转移组的肿瘤直径为(0.87±0.12)cm,对比差异有统计学意义(P<0.05)。所有患者都顺利完成CT扫描,图像无伪影,靶平面保持良好。有淋巴结转移组的PS与BV值都明显高于无淋巴结转移组(P<0.05)。经过CT判定为淋巴结转移61例,无淋巴结转移17例,与手术病理判定对比,螺旋CT诊断胃癌淋巴结转移的敏感性与特异性分别为100.0%和94.4%。结论:16排螺旋CT诊断胃癌淋巴结转移能获得更好的肿瘤血液动力学信息,具有很好的诊断敏感性与特异性,对胃癌制定合理治疗方案及判断预后有重要的临床意义。  相似文献   

8.
目的 探讨在胸部肿瘤扫描中双源CT双能量方法虚拟平扫及双能量碘分布图技术的临床应用价值.方法 分析58例患者胸部肿瘤性病变的CT及临床资料.比较双能量组经处理得到的虚拟平扫与常规平扫相关指标,比较双能量组经处理得到的碘分布图强化CT值与常规组人工测量强化值对病灶良、恶性鉴别诊断的准确度.结果 虚拟平扫与常规平扫图像质量评分分别为(4.62±0.52)、(4.71±0.46)分(t=2.319,P> 0.05),图像噪声分别为(8.10±1.16)、(7.30±1.06) HU(t=5.246,P< 0.05),有效剂量分别为(5.18±0.96)、(5.55±1.18)mSv(t=4.005,P<0.05).碘分布图CT值与净强化CT值有良好相关性.结论 虚拟平扫图像对肺部病变显示良好,可满足诊断要求,有代替胸部常规平扫的潜在价值.双能量碘分布网反映血供的能力更直接、更敏感,可以定量表达病灶的强化程度,为临床肿瘤病变诊断提供更丰富的信息.  相似文献   

9.
螺旋CT诊断囊性肾癌的价值   总被引:8,自引:1,他引:7  
目的探讨囊性肾细胞癌(简称囊性肾癌)的螺旋CT(SCT)表现和诊断价值。方法对17例经手术病理证实为囊性肾癌患者的SCT图像进行回顾性分析。患者临床表现无特殊,6例偶有腰痛,2例有腹痛,2例发现过肉眼血尿。17例中,9例为体检时B超发现肾脏囊性占位病变,进一步做SCT检查而发现;8例为随访肾囊肿时发现。使用Siemens Somatom plus单层螺旋CT或Siemens Sensation 16层螺旋CT,先行常规平扫,再行增强扫描。增强扫描使用非离子对比剂80—100ml,经前臂静脉用压力注射器给药,注射流率为2—3ml/s。分别于注射对比剂后30—40s时开始动脉(皮质)期扫描,60-70S时开始静脉(髓质、实质)期扫描,120—180s时再行排泄(肾盂)期扫描。原始扫描数据传送至Siemens Volume Wizard工作站,进行各种图像重建及后处理。结果病灶位于右肾5例,位于左肾12例。病变通常为圆形、类圆形囊性密度肿块,边缘光整;直径2.1—10cm,平均5.7cm。其中病变直径〉5cm者15例,占88.2%。病灶属单房者10例,多房者7例。多房者囊内可见1—5条分隔,SCT显示囊壁和间隔多数厚薄均匀(1—2mm),增强扫描可见轻度强化,其中2例可见附壁小结节。平扫时,囊液CT值近于水或略高,其中1例为均匀血液密度(48HU);增强扫描时,囊液均不强化。本组病例少见侵袭性生长,3例可见局部浸润;未见有淋巴结转移者。仅1例于术后5年死于肺转移癌。结论囊性肾癌生物学行为较好,影像学表现相对有特征性,SCT可作为术前诊断的手段。  相似文献   

10.
Wang XM  Wu LB  Zhang YT  Li ZJ  Liu C 《中华肿瘤杂志》2006,28(11):876-878
目的探讨多层螺旋CT(MSCT)动态增强扫描诊断结肠淋巴瘤的价值。方法对16例结肠淋巴瘤患者进行MSCT动态增强扫描,并观察分析MSCT轴位图像和多平面重组(MPR)、容积重建(VR)及CT仿真内窥镜(CTVE)等重建图像,进行诊断。同时行双对比钡灌肠检查和纤维结肠镜检查。结果16例结肠淋巴瘤患者中B细胞型淋巴瘤14例,MSCT动脉期增强扫描见病灶呈轻、中度均质强化,诊断为结肠淋巴瘤;T细胞型淋巴瘤2例,MSCT动脉期增强扫描呈中度不均质强化,诊断为结肠癌。MSCT动态增强扫描与病理诊断的符合率为87.5%,高于双对比钡灌肠检查和纤维结肠镜检查。结论MSCT动态增强扫描结合后处理图像在结肠淋巴瘤的诊断中具有独特的优越性,其诊断符合率高于双对比钡灌肠检查和纤维结肠镜检查。  相似文献   

11.
The aim of this study was to evaluate the risk of thrombo-embolic events (TEE) in patients with germ-cell tumours (GCT) who receive cisplatin-based chemotherapy, to compare this risk to that of a matched control group of non-GCT cancer patients, and to identify risk factors of TEE. The rate of TEE during the 6 months following the initiation of chemotherapy was assessed in 100 consecutive patients with GCT and in 100 controls with various neoplasms who were matched on sex and age, and who received first-line cisplatin-based chemotherapy during the same period of time at Institut Gustave Roussy, Villejuif, France. Data were subsequently tested on a validation group of 77 GCT patients treated in Lyon, France. A total of 19 patients (19%) (95% confidence interval (CI): 13-28) and six patients (6%) (95% CI: 3-13) had a TEE in the GCT group and the non-GCT control group, respectively (relative risk (RR): 3.4; P<0.01). Three patients from the GCT group died of pulmonary embolism. In multivariate analysis, two factors had independent predictive value for TEE: a high body surface area (>1.9 m2) (RR: 5 (1.8-13.9)) and an elevated serum lactate dehydrogenase (LDH) (RR: 6.4 (2.3-18.2)). Patients with no risk factor (n=26) and those with at least one risk factor (n=71) had a probability of having a TEE of 4% (95% CI: 1-19) and 26% (95% CI: 17-37), respectively. In the GCT validation set, 10 (13%) patients had a TEE; patients with no risk factor and those with at least one risk factor had a probability of having a TEE of 0 and 17% (95% CI: 10-29), respectively. Patients with GCT are at a higher risk for TEE than patients with non-GCT cancer while on cisplatin-based chemotherapy. This risk can be accurately predicted by serum LDH and body surface area. This predictive index may help to study prospectively the impact of thromboprophylaxis in GCT patients.  相似文献   

12.
目的:初步探索以PET/CT图像为基准的能谱CT平扫成像在宫颈癌诊断中的应用价值。方法:回顾性收集我院21例病理证实为宫颈鳞状细胞癌的患者,所有患者术前均行PET/CT扫描及能谱CT扫描,以PET/CT融合图像为参照,在能谱CT图像上勾画感兴趣区,记录宫颈癌病灶及周围正常组织有效原子序数(effective atomic number,Eff-Z)值、单能量70 keV下的CT值和能谱曲线,绘制ROC曲线,得出最佳诊断阈值。结果:宫颈癌病灶及周围正常组织的Eff-Z值及70 keV下的CT值差异具有统计学意义(P<0.05)。宫颈癌病灶Eff-Z值为7.33±0.09(7.1~7.5);病灶周围正常组织Eff-Z值为7.01±0.10(6.8~7.2);Eff-Z为7.25时,敏感度为90.5%,特异度为100%。70 keV单能量重建成像宫颈癌病灶CT值为(38.27±5.04)HU(29.2~50.9 HU),病灶周围正常组织CT值为(29.79±7.14)HU(19.9~43.1 HU);CT值为34.2 HU时,敏感度为85.7%,特异度为76.2%。宫颈癌病灶能谱曲线平直,病灶周围正常组织曲线在40~70 keV呈上升趋势,之后趋于平缓。结论:能谱CT在宫颈癌诊断中有一定的作用。  相似文献   

13.
目的 分析肺癌患者放疗前灌注状态及其放疗前后CT灌注成像参数改变与放疗疗效关系。方法 以28例临床及病理确诊肺癌患者为研究对象,CT灌注成像扫描并计算灌注值:血流量(BF)、血容量(BV)、平均通过时间(MTT)及表面通透性(PS)。肺癌患者放疗前CT灌注成像值与靶体积相关性采用线性相关分析,缓解组与未缓解组差异行独立样本t检验,放疗前后CT灌注成像值比较行配对样本t检验。结果 28例肺癌患者放疗缓解组16例、未缓解组12例。放疗前后缓解组病灶体积明显缩小[(58.72±22.95) cm3∶(24.53±13.79) cm3,P=0.000],但放疗前靶体积与各灌注值无明显相关(P=0.628)。放疗前缓解组与未缓解组BF、BV值不同(1.23±1.36∶6.42±2.57,P=0.024与1.23±0.31∶0.59±0.18,P=0.041),MTT、PS差异未达统计学水平(0.93±0.58∶0.93±0.66,P=0.851与1.46±0.83∶1.17±0.56,P=0.141)。放疗前后BF、BV、MTT、PS值不同(9.81±3.56∶7.48±3.31,P=0.006;0.96±0.41∶0.64±0.38,P=0.003;0.93±0.60∶0.53±0.30,P=0.007;1.34±0.73∶0.74±0.44,P=0.001)。结论 CT灌注成像能预测肺癌放疗后的疗效,在一定程度能指导肺癌精确放疗的计划及实施。  相似文献   

14.
背景与目的 计算机断层扫描(computed tomography,CT)随访评估结节体积及密度变化是临床针对不定性肺结节采用的常用策略.在保证测量精度前提下降低CT剂量是需要考虑的问题.本研究旨在评估不同管电流及重建算法对肺体模结节容积定量及CT值测量的影响.方法 应用64排螺旋CT,管电压120 kV,7种管电流(10 mA、20 mA、50 mA、80 mA、100 mA、150 mA、350 mA)对肺结节体模进行扫描,采用滤波反投影(filtered back projection,FBP)、自适应迭代重建(ASIR:30%,50%,80%)算法进行重建,获取28套CT图像.应用肺结节分析软件对3种直径(2.5 mm,5 mm,10 mm)、三种CT值(-100 HU,60 HU,100 HU)共9个球型结节测量容积及平均CT值数据.应用重复测量方差分析评估不同管电流及原始数据重建算法对容积及CT值测量的影响.结果 直径为2.5 mm结节的容积测量相对误差(100.8%±28%)及三维CT值绝对误差(-756±80)HU最大;直径为5 mm及10 mm结节的容积相对误差小[(-0.9%±1.1%)vs(0.9%±1.4%)],但CT值绝对误差大[(-243±26)HUvs(-129±7)HU].针对直径为5 mm及10 mm结节使用重复测量方差分析结果显示,应用不同管电流及原始数据重建算法时容积测量相对误差没有显著性差异(F=5.60,P=0.10 vs F=11.13,P=0.08),三维CT值的绝对误差有显著影响(F=34.79,P<0.001 vs F=156.14,P<0.001).结论 不同管电流及重建算法对直径5 mm及10 mm的结节容积定量影响很小,因此较低管电流及迭代重建算法可以应用在5 mm以上肺结节的CT随访中.结节分析软件提供的平均CT值与标准CT值在不同大小、密度结节中均具有较大误差,不能应用于临床.  相似文献   

15.
  目的   探讨18F-FDG PET/CT显像在原发性胆囊癌诊断中的价值, 并与增强CT、B超及MRI进行比较。   方法   收集2006年3月至2011年12月期间38例临床疑似胆囊癌而在本院行PET/CT检查的患者, 其中男26例, 女12例; 年龄46~82岁, 中位年龄69岁。患者均行PET/CT、增强CT、B超及MRI检查。全部病例均经手术病理及临床随访证实, 其中35例为原发胆囊癌, 3例为胆囊炎。分别统计4种影像诊断方法的真阳性率、假阳性率、真阴性率、假阴性率及诊断正确率。   结果   PET/CT、增强CT、B超及MRI检查的真阳性率分别为100.0%、74.3%、60.0%、71.4%;假阴性率分别为0、25.7%、40.0%、28.6%;增强CT、B超及MRI检查真阴性率分别为66.7%、33.3%、66.7%;假阳性率分别为33.3%、66.7%、33.3%。诊断正确率分别为92.1%、71.1%、60.5%、68.4%。PET/CT与增强CT、B超及MRI结果比较, P值分别为0.036、0.002、0.019, 均P < 0.05。   结论   在原发性胆囊癌诊断中, PET/CT较其他3种传统影像诊断方法准确率高。如将PET/CT结合增强CT检查, 可使诊断正确率提高2.6%。故18F-FDG PET/CT显像对原发性胆囊癌的诊断具有重要的临床应用价值。   相似文献   

16.
目的 探讨非霍奇金淋巴瘤(non-Hodgkin's lymphoma,NHL)患者治疗前18F-FDG PET/CT显像中最大标准化摄取值(SUVmax)与疗效的关系。方法 回顾性分析2017年7月—2019年3月在我科行18F-FDG PET/CT显像并经淋巴结活检确诊为NHL的146例患者的资料。根据国际工作组织淋巴瘤疗效评估标准(IWC)将化疗6个疗程的NHL患者分为有效组和无效组。分析SUVmax与临床病理特征及疗效的关系。结果 在NHL患者中,临床分期、恶性程度、病灶大小、坏死情况、骨髓浸润、治疗前血清乳酸脱氢酶、Ki-67阳性率与SUVmax有关(P<0.05);无效组治疗前SUVmax高于有效组(16.68±6.16 vs 12.16±5.27,t=4.654,P=0.001);治疗前SUVmax评估NHL患者疗效的最佳截断值为14.836,对应的 AUC为0.835(95%CI:0.751~0.920),特异度为80.0%,敏感度为77.4%;治疗前SUVmax>14.836是影响NHL患者疗效的独立危险因素(OR=1.688,95%CI:1.179~2.418,P=0.007)。 结论 18F-FDG PET/CT显像中的SUVmax可评估NHL患者的化疗疗效。  相似文献   

17.
目的:探讨第3代双源CT能谱纯化Sn100 kV超低剂量扫描与64排螺旋CT低剂量扫描对比在乳腺及肺联合筛查中对图像质量和辐射剂量的影响。方法:回顾性分析40例行第3代双源CT Sn100 kV胸部超低剂量扫描的女性体检者为实验组,另选取40例采用64排螺旋CT扫描机行低剂量胸部CT筛查的女性体检者为对照组,比较两种扫描方案乳腺和肺的图像质量和辐射剂量。结果:在乳腺及肺客观图像质量对比中,实验组气管、腋下脂肪、肩胛下肌噪声值较对照组均有所下降(P<0.05),差异有统计学意义;同时,实验组信噪比(SNR)较对照组均有所提升,差异有统计学意义(P<0.05)。实验组乳腺腺体噪声亦较对照组下降(P=0.00)。实验组的肺及乳腺图像质量主观评分均优于对照组,评分差异有统计学意义(P<0.05),两名评价者之间一致性强Kappa=0.82。实验组的剂量长度乘积(DLP)及有效辐射剂量(ED)较对照组明显下降(约达86%)。结论:第3代双源CT Sn100 kV超低剂量扫描方案较64排螺旋CT低剂量扫描可在提高乳腺及肺图像质量的同时显著降低辐射剂量,为临床通过胸CT扫描对女性体检者进行肺癌及乳腺癌联合筛查提供了新的参考,达到“一查双筛”的目的。  相似文献   

18.
目的:评价CT增强检查在小儿神经母细胞瘤化疗监测中的作用。方法:搜集经病理证实、临床影像资料完整的小儿神经母细胞瘤患者44例,男26例,女18例,年龄2个月到7岁,平均3.15岁。分为术前组(10例)和术后组(34例)。所有患者化疗前后均行增强CT检查,对比分析化疗前后的CT图像。结果:CT增强检查可以清晰显示原发肿瘤的体积及肿块内钙化的变化,了解肿瘤推挤临近器官或包绕大血管的情况;帮助判断原发肿瘤部位有无复发、残留;明确有无远处转移及其变化。结论:无论是手术前还是手术后化疗,CT增强扫描均是帮助评价小儿神经母细胞瘤化疗疗效的重要手段。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号