首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 203 毫秒
1.
探讨炫速双源CT血管成像(Flash CTA)在下肢动脉闭塞症的临床应用方法及价值。选择27例临床疑有下肢动脉硬化闭塞症患者进行炫速双源CT血管成像扫描,检查后2周内均行数字减影血管造影(DSA)检查。将采集到的图像进行最大密度投影(MIP)、容积重组(VR)及多平面重建(MRP)。血管狭窄程度分级:1级,无狭窄或狭窄程度10%;2级,狭窄程度10%~49%;3级,狭窄程度50%~99%;4级,闭塞。27例患者腹主动脉下段至小腿动脉显示对比度均可达到诊断要求,与DSA结果相比较,Flash CTA的准确性、敏感性、特异性、阳性预测值、阴性预测值和分别为94.5%、96.2%、92.9%、93.2%、96.0%。Flash CTA能准确定位和分级下肢动脉的狭窄和闭塞程度,是一种可靠、无创的检查方法,具有重要临床价值。  相似文献   

2.
目的 探究CT血管造影(CTA)+彩色多普勒血流显像(CDFI)检查对脑动脉瘤(CA)诊断效能。方法 选取2019年3月~2021年9月我院收治的221例疑似CA患者,均行CTA、CDFI检查,以三维数字减影血管造影(3D-DSA)检查为金标准,观察CTA、CDFI检查结果,分析两种检查方式单独及联合检查诊断效能,对比CTA、CDFI检查瘤体检出数量、具体瘤体部位符合率、瘤体最大直径、瘤颈径。结果 221例疑似CA患者中,3D-DSA检查显示阳性134例,CDFI检查显示阳性122例,CTA检查显示阳性124例,CTA+CDFI检查显示阳性140例。CTA+CDFI检查灵敏度(97.76%)、准确度(94.57%)、阴性预测值(96.30%)高于CDFI(85.07%、87.33%、79.80%)、CTA(85.82%、87.33%、80.41%)单独检查(P<0.05);CTA+CDFI检查漏诊率(2.24%)低于CDFI(14.93%)、CTA(14.18%)单独检查(P<0.05);CTA+CDFI检查与3D-DSA检查金标准CA瘤体最大直径、瘤颈径对比无显著差异(P...  相似文献   

3.
CT三维血管造影诊断出血动脉瘤   总被引:2,自引:0,他引:2  
目的 评价CT血管造影(CTA)在颅内动脉瘤破裂后蛛网膜下腔出血诊断中的价值及手术指导意义。方法 对63例急性蛛网膜下腔出血病人急诊行螺旋CT扫描,然后行脑血管三维成像。结果 发现颅内动脉瘤24例。有1例阴性经全脑血管造影(DSA)发现存在动脉瘤。诊断均以手术证实。结论 CTA对动脉瘤蛛网膜下腔出血是一种微创、快速、准确的诊断技术,对于急诊或危重病人应为首选。  相似文献   

4.
目的探讨锥形束CT(CBCT)联合iGuide引导系统在经皮经胸肺穿刺活检术(PTNB)中的应用价值。方法纳入30例因肺部单发病灶接受PTNB的患者。CBCT扫描后,通过iGuide引导系统和三维类CT多平面重组图像规划穿刺路径。采用18G同轴切割针行穿刺活检。记录手术相关资料、穿刺并发症及辐射剂量。结果 30例患者中,穿刺活检病理结果显示恶性病变24例,良性病变6例;28例符合最终病理诊断,1例为取材不够,但重新取材后的病理结果符合最终病理诊断,1例为假阴性结果。PTNB诊断肺部病变的准确率、敏感度、特异度、阳性预测值及阴性预测值分别为96.67%(29/30)、96.00%(24/25)、100%(5/5)、100%(24/24)及83.33%(5/6)。平均手术时间为(13.03±3.61)min,平均有效辐射剂量为(7.95±4.57)mSv。活检术后CBCT复查发现气胸6例(6/30,20.00%),咯血3例(3/30,10.00%)。结论CBCT联合iGuide引导系统引导下PTNB具有较高诊断准确率和安全性以及合理的辐射暴露。  相似文献   

5.
目的探讨经阴道超声(TVS)及宫腔镜(HS)诊断子宫内膜病变的临床价值。方法回顾性分析2008年8月—2011年5月接受TVS、HS和病理检查的疑似子宫内膜病变患者192例,与病理结果对照,评价两种方法诊断子宫内膜病变的敏感度、特异度、阳性预测值、阴性预测值及诊断符合率,并进行统计学比较。结果 TVS诊断子宫内膜异常的敏感度、特异度、阳性预测值、阴性预测值分别为93.60%(161/172)、55.00%(11/20)、94.71%(161/170)、50.00%(11/22);HS诊断子宫内膜异常的敏感度、特异度、阳性预测值、阴性预测值分别为97.67%(168/172)、90.00%(18/20)、98.82%(168/170)、81.82%(18/22)。HS的诊断敏感度、特异度、阳性预测值、阴性预测值均高于TVS;HS及TVS对子宫内膜增生、内膜息肉、黏膜下肌瘤、内膜癌、内膜萎缩的诊断符合率差异均无统计学意义(P均>0.05),慢性非特异性子宫内膜炎、未见异常者的诊断符合率差异有统计学意义(P均<0.05)。结论 TVS可作为子宫内膜病变的首选检查方法,为HS提供导向;TVS与HS相结合,有望成为诊断子宫内膜病变的最佳方法。  相似文献   

6.
目的探讨低注射速率、低剂量对比剂3D-DSA脑血管造影的的可行性。方法连续收集疑似动脉瘤患者51例行3D-DSA脑血管造影,选择DynaCT 5sDSA成像,均采用非离子型对比剂碘普罗胺注射液(370mgI/100ml),导管尖端均位于平枢椎水平,按对比剂注射速率随机分为A组(1.5ml/s,n=18)、B组(2.0ml/s,n=18)、C组(3.0ml/s,n=15)。计算C臂锥形束CT轴位图像颈内动脉岩段(C2段)和眼段(C6段)、大脑中动脉水平段(M1段)、大脑前动脉水平段(A1段)的噪声、SNR及CNR,由2名医师对连续减影图像、VR及MIP重组图像的图像质量进行评分后行统计学分析。结果 B、C组与A组噪声的差异均无统计学意义(P均0.05)。A组与B组比较,M1、A1段的SNR、CNR差异均有统计学意义(P均0.05),C2、C6段SNR、CNR差异均无统计学意义(P均0.05);A组与C组比较,C2、C6、M1及A1段的SNR、CNR差异均有统计学意义(P均0.05)。3组间大脑中动脉、大脑前动脉连续减影图像及VR、MIP图像的图像质量主观评分差异均无统计学意义(P均0.05),均可充分显示颅内动脉瘤情况。结论 3D-DSA脑血管造影中实施个性化低注射速率、低剂量对比剂注射方案可行,能够降低患者碘摄入量及血管破裂出血风险。  相似文献   

7.
目的探讨开放式MR实时透视技术在颅脑病变穿刺活检中的应用价值。方法回顾性分析112例接受1.0T开放式MR实时透视引导颅脑病变穿刺活检患者,以活检后外科手术病理结果或随访结果作为最终诊断标准,计算穿刺活检诊断颅脑病变的准确率、敏感度、特异度、阳性预测值及阴性预测值。结果 112例患者共穿刺112个病灶,最大径0.91~4.53 cm,平均(2.32±0.81)cm;其中29例病灶最大径≤1.5 cm,83例1.5 cm。112例均成功取材,对其中108例获得明确穿刺病理学诊断结果。穿刺术中4例出现少量颅内出血,未见其他严重并发症,并发症发生率为3.57%(4/112)。穿刺活检诊断准确率、敏感度、特异度、阳性预测值及阴性预测值分别为96.43%(108/112)、96.34%(79/82)、96.67%(29/30)、98.75%(79/80)及90.63%(29/32),最大径≤1.5 cm与1.5 cm病灶诊断准确率、敏感度、特异度、阳性预测值及阴性预测值差异均无统计学意义(P均0.05)。结论 1.0T开放式MR实时透视引导颅脑病变穿刺活检安全、可行。  相似文献   

8.
目的探讨冠状动脉左主干病变(LMCD)的双源CTA影像特征及临床应用。方法回顾性分析经双源CTA诊断的LMCD患者33例,分析其临床资料,按照左主干50%,左前降支、回旋支或右冠状动脉≥70%定义目标血管,经CT图像后处理,于心脏短轴层面观察节段心肌密度,分析其影像特点,同期行CAG,术后随访3个月。结果 33例患者中,双源CTA确定目标血管75支,以CAG为金标准,CTA诊断主要血管病变72支,准确率96.00%(72/75),9支(9/33,27.27%)冠状动脉左主干为单纯LMCD,24支(24/33,72.73%)LMCD合并其他主要血管病变,其中20支冠状动脉左主干合并末端岔口病变。29例(29/33,87.88%)例患者46节段CTA显示心肌密度减低,23例34节段位于心内膜下,6例12节段为透壁性。对42支(42/75,56.00%)血管行经皮冠状动脉介入治疗(PCI),其中22支病变局限、行单纯PCI,20支为左主干末端岔口病变、行PCI同时覆盖左前降支或回旋支开口。13支(13/75,17.33%)采用冠状动脉旁路移植术,20支(20/75,26.67%)采用药物保守治疗,随访3个月,未发现主要不良心血管事件。结论冠状动脉双源CTA可发现LMCD部位及范围,发现其他血管病变及异常血流灌注的节段心肌,为临床病情评估及治疗提供客观依据。  相似文献   

9.
目的探讨80 kVp管电压冠状动脉CTA(CCTA)联合体积自适应统计迭代重建-V(ASiR-V)图像重建应用于超重和Ⅰ级肥胖患者的可行性。方法将120例接受CCTA检查的超重和Ⅰ级肥胖患者随机分为80 kVp组和100 kVp组,每组60例,分别于80、100 kVp管电压下行CCTA,并采用权重为60%的ASiR-V进行图像重建。对比2组图像质量,各部位CT值、SNR、对比噪声比(CNR)、容积CT剂量指数(CTDIvol)、剂量长度乘积(DLP)、对比剂剂量及有效辐射剂量。结果 80 kVp组和100 kVp组图像质量评分差异无统计学意义(P0.05)。2组CTDIvol、DLP、对比剂剂量、有效辐射剂量差异均有统计学意义(P均0.05);2组主动脉根部、右冠状动脉、左前降支及左回旋支CT值差异无统计学意义,右冠状动脉、左前降支及左回旋支SNR、CNR差异无统计学意义(P均0.05)。结论 80 kVp管电压CCTA联合60%ASiR-V图像重建应用于超重和Ⅰ级肥胖患者,可获得与100 kVp管电压相当的图像质量,且对比剂剂量及有效辐射剂量均减少。  相似文献   

10.
目的探讨冠状动脉CTA中以体质量指数(BMI)与体表面积(Suf)作为个体化分类标准,联合100kV低管电压扫描,降低对比剂用量、提高造影效率和图像质量的价值。方法入组患者17.0≤BMI26.5,分为120kV组(A组)与100kV组(B组),各100例。A组扫描管电压120kV,管电流600mA;对比剂0.8~1.0ml/kg(总量约65ml),生理盐水50ml,注射流率均为5.0ml/s。A组检查完毕后采用线性回归分析对比剂用量与BMI、Suf关系,制成量化速查表。B组扫描管电压100kV,管电流600mA;对比剂根据上述速查表采用35~65ml,生理盐水30~50ml(对比剂总量×80%),注射流率均为5.0ml/s。结果两组对比剂用量、主动脉强化值、左心室强化值、图像噪声、辐射剂量指数、有效剂量差异均有统计学意义(P均0.05),B组较A组对比剂用量下降28.16%、主动脉强化值提高21.58%;辐射剂量指数下降39.54%、有效剂量下降40.83%、噪声值升高27.15%。两组图像质量评分B组优于A组(P0.01)。结论以BMI、Suf作为个体化分类标准,可降低检查中对比剂用量、提高造影效率;结合100kV低管电压扫描,能在显著降低辐射剂量的同时改善图像质量。  相似文献   

11.
CTA、MRA诊断脑动静脉畸形:与DSA比较   总被引:1,自引:0,他引:1  
目的比较CTA、MRA与DSA对脑动静脉畸形(AVM)的诊断价值。方法回顾性分析经DSA确诊为脑AVM的48例患者的脑CTA及MRA图像,并统计其诊断效率。结果27例患者接受颅脑CTA检查,7例大型脑AVM(直径〉6cm)与DSA结果一致,12例中型脑AVM(直径3-6cm)中1例CTA未检出,8例小型脑AVM(直径〈3cm)中CTA漏诊3例,CTA与DSA检查结果的差异有统计学意义(P〈0.05)。对21例患者行MRA检查,其中14例大、中型脑AVM(直径≥3cm)MRA诊断结果与DSA一致,7例小型脑AVM(直径〈3cm)中MRA漏诊4例,与DSA检查结果的差异有统计学意义(P〈0.05)。结论CTA、MRA诊断大、中型脑AVM与DSA基本相符,而对于小型脑AVM的诊断效率较低。  相似文献   

12.
Spontaneous subarachnoid haemorrhage is a clinical condition that may be attributed to various underlying causes, such as rupture of intracranial aneurysms and arteriovenous malformations (AVMs). Suspected cerebrovascular abnormalities can be detected either with digital subtraction angiography (DSA) or with computed tomography angiography (CTA) combined with postprocessing tools, namely multiplanar reformation, maximum intensity projection, shaded surface display, virtual endoscopy and direct volume rendering. We prospectively studied a group of 205 patients with spontaneous subarachnoid haemorrhage. One-hundred-ninety-eight patients underwent both DSA and CTA, and formed our study group. Patients with intracranial aneurysms underwent surgical or endovascualar treatment. DSA was negative for 35 patients, detected 178/179 aneurysms and 15 AVMs. CTA correctly detected 176/179 aneurysms and all 15 cases of AVMs, whereas it was negative in 35 cases. After 3D reconstruction the size, location and the relationship to the parent vessel of the aneurysms, the extent of the AVMs with the main feeding vessel(s), nidus and draining veins were reliably shown by CTA, although DSA provided more anatomic details related to the anatomy of the adjacent vessels. The accuracy, sensitivity, positive predictive accuracy and negative predictive accuracy for CTA was 98, 97.9, 100 and 94.3% and for DSA was 99, 99.3, 100 and 98%, respectively. It is suggested that CTA is a reliable alternative to DSA in detecting intracranial aneurysms. The role of CTA in demonstrating AVMs can be considered complementary to that of DSA.  相似文献   

13.
Helical computed tomographic angiography (CTA) is a relatively new noninvasive volumetric imaging technique. Since early reports in the 1990s, CTA has rapidly improved image resolution and scan volume. Cerebral arteries can be imaged clearly, which is advantageous in the diagnosis of vascular diseases such as cerebral aneurysms, arteriovenous malformations, and cerebrovascular occlusive disease. Before attacking a cerebrovascular lesion near or in the skull base, precise preoperative knowledge of anatomic relationships between the bony and neurovascular structures is critical for obtaining successful outcomes. The sensitivity of CTA for the detection of cerebral aneurysms < or = 5 mm in diameter may be higher than that of digital subtraction angiography (DSA), with equal specificity and high interoperator reliability. With minor modification to the technique, paraclinoid vascular lesions can be depicted using CTA. We present our experience using CTA in addition to DSA to obtain important anatomic information about skull base vascular lesions that assisted in the clinical decision-making process.  相似文献   

14.
目的探讨双源CT头颈心一站式扫描对动脉粥样硬化(AS)患者的应用价值。方法将120例AS患者随机分为2组,每组60例。对A组行头颈心一站式扫描,B组分别行常规冠状动脉CTA及头颈部血管CTA扫描。对2组图像质量进行主观及客观评价;主观评分采用3分法,客观评价指标包括左冠状动脉主干、右冠状动脉中段、颈总动脉近分叉处、颈内动脉C1段、大脑中动脉M1段血管的平均SNR及其相对于脊柱旁肌肉的CNR。记录2组CTA扫描长度、扫描时间、剂量长度乘积(DLP)和有效剂量(ED),并进行统计学分析。结果 2组图像质量评分差异无统计学意义(t=0.596,P=0.283),SNR及CNR差异亦无统计学意义(t=0.828、0.761,P=0.104、0.089)。2组间CTA扫描长度差异无统计学意义(t=1.351,P=0.621),但A组较B组扫描时间更短[(1.30±0.12)s vs (4.08±0.69)s,t=-2.831,P=0.006],DLP[(146.03±13.05)mGy·cm vs (1 935.04±134.12)mGy·cm,t=-6.743,P0.01]及ED[(0.88±0.32)mSv vs (9.62±1.64)mSv,t=-4.056,P0.01]更低。结论对AS患者,双源CT头颈心一站式扫描技术能获得满意的冠状动脉、头颈动脉图像,同时显著降低辐射剂量。  相似文献   

15.
目的 探讨大脑中动脉巨大型动脉瘤的手术治疗方法.方法 回顾性分析2001年1月至2008年3月17例颅内大脑中动脉巨大型动脉瘤患者的手术方法和疗效.术前采用CT、CTA、MR、MRA、DSA及三维DSA检查,以了解动脉瘤的部位、大小,形状以及侧支代偿情况,制定个体化治疗方案.在手术入路上多采用改良翼点入路,其中行动脉瘤瘤颈直接或塑形夹闭者4例,动脉瘤孤立或孤立后切除4例,动脉瘤切除或孤立后血管重建7例,动脉瘤包裹2例.结果 CT和MRI能清楚地显示动脉瘤的形状、大小.DSA及三维DSA能显示瘤颈以及与附近血管和骨质的关系.根据格拉斯骨预后评分表评分,出院时恢复优良者12例,中度病残4例,重度病残1例,无死亡病例.结论 术前有必要进行详细的影像学检查,有助于术者规划手术方法,制定个体化治疗方案,采用不同术式取得良好预后.载瘤动脉暂时性阻断、动脉瘤切开血栓清除均有助于瘤颈夹闭.血管重建技术为大脑中动脉巨大型动脉瘤的手术治疗开辟了新途径,明显改善了手术效果.  相似文献   

16.
目的 分析3D影像融合技术用于腔内介入治疗主动脉病变的价值。方法 回顾性分析18例接受3D影像融合引导腔内介入治疗主动脉病变患者。于Siemens Artis Pheno工作站以Syngo-X-workshop软件将术前主动脉CT血管造影(CTA)与术中锥形束CT (CBCT)图像进行融合,分别于T10~L3椎体水平进行冠状位、矢状位及轴位3个维度的配对融合,将最终形成的3D融合影像投射至实时数字减影血管造影(DSA)影像中,用于导引主动脉腔内介入操作。记录治疗用时、碘对比剂用量及射线剂量等。结果 18例中,腹主动脉瘤7例、主动脉穿透性溃疡5例、胸主动脉夹层4例、胸主动脉瘤2例;对11例行腹主动脉瘤腔内修复术(EVAR)、7例行胸主动脉腔内修复术(TEVAR),均获得成功,技术成功率100%;治疗用时(124.28±55.95) min,碘对比剂用量(178.89±37.87) ml,辐照时间(20.21±13.20) min,CBCT辐射剂量(225.17±60.10) mGy,总辐射剂量(815.68±439.10) mGy。7例术前合并肾功能不全,术后24 h、出院前及术后1、3个月血肌酐值与术前比较差异均无统计学意义(P均>0.05)。结论 3D影像融合技术用于腔内介入治疗主动脉病变安全、可行。  相似文献   

17.
多层螺旋CT血管成像诊断脑动脉瘤:与DSA对比研究   总被引:19,自引:0,他引:19  
目的 探讨16层螺旋CT容积再现脑血管成像技术对脑动脉瘤的诊断价值。方法 对23例临床怀疑脑动脉瘤患者(其中蛛网膜下腔出血者20例)的16层螺旋CT三维血管后处理图像、DsA图像进行回顾性对比研究。CT后重建技术分别采用小视野容积再现技术(shutter volume rendering)、最大密度投影法(M1P)和多曲面重建(MPR),所有CT图像及DSA脑血管造影图像均由两位放射科医生和两位脑外科医生进行双盲法分析评价。结果 16层螺旋CT脑血管成像共检出动脉瘤25个,其中3例为多发性,1例CT血管成像(CTA)结果为阴性,阳性率95.7%(22/23),与DSA比较符合率95.7%(22/23);16层CTA发现动脉瘤的敏感性为100%(24/24),特异性为100%(1/1),准确性为96.2%(25/26)。CTA对显示瘤体、瘤颈、载瘤动脉与周围血管关系与DSA相比更清晰、确切,并能显示病灶与颅骨结构间的关系,立体感强。结论 16层螺旋CT脑血管成像对脑动脉瘤具有极高的诊断价值,相对无创是诊断脑动脉瘤的最佳影像检查方法,有望替代DSA。  相似文献   

18.
BACKGROUND: Digital subtraction angiography (DSA) is considered the gold standard in the evaluation of cerebrovascular structures. Recently, 3-dimensional DSA (3D-DSA) has been increasingly used to obtain detailed information about the morphology and dimensions of intracranial aneurysms. We report the case of a patient who presented with a distal pericallosal artery aneurysm, which appeared by 2D imaging to be a fusiform, possible mycotic aneurysm. This was then revealed to be a saccular bifurcation aneurysm by 3D-DSA. This additional information changed the treatment plan for this patient from medical management to a surgical approach. CASE DESCRIPTION: The patient is a 56-year-old man with a history of hypertension and alcohol abuse with withdrawal seizures, who presented with a large intracranial hemorrhage on initial computed tomography scan. After stabilization with intracranial pressure management, the patient underwent magnetic resonance angiography and 4-vessel DSA. These initial studies showed a distal, fusiform pericallosal aneurysm consistent with a mycotic aneurysm. Rotational DSA was then used to generate 3D images of the structure that revealed a saccular bifurcation aneurysm. This enabled the decision to offer operative treatment rather than conservative medical management. DISCUSSION: This report highlights the value of 3D-DSA in establishing the appropriate treatment plan for patients with unique cerebral aneurysms. The higher resolution images used in this case provided information that was crucial in shifting the treatment focus from medical management, for what appeared to be a mycotic aneurysm by traditional DSA, to surgical intervention, for a clear hemodynamic aneurysm at a vessel bifurcation seen with 3D-DSA. Accurate pre-interventional evaluation and differential diagnosis are critical to designing the most effective lowest risk treatment plan. The standard method in the diagnosis of cerebral aneurysms has been DSA. Yet, higher resolution images of unclear or high-risk aneurysms are often required to guide clinical decision making. The emergence of new, less invasive endovascular techniques for securing intracranial aneurysms has placed greater emphasis on precisely defining the shape and dimensions of an aneurysm. Three-dimensional DSA is currently the highest resolution imaging modality available for the evaluation of intracranial aneurysms. CONCLUSION: 3D-DSA was used to evaluate a small, distal pericallosal artery aneurysm and revealed a saccular bifurcation aneurysm not visualized with magnetic resonance angiography and conventional DSA. This additional resolution permitted the team to consider a surgical approach for a patient who would otherwise have been treated medically. This high-resolution technique is particularly useful in guiding clinical decision making in the context of aneurysms that carry a relatively broad differential diagnosis, potentially high interventional risk, and unclear morphology.  相似文献   

19.
平板3D-DSA在颅内动脉瘤诊断和介入治疗中的价值   总被引:2,自引:1,他引:1  
目的评估平板探测器三维数字减影血管造影(3D-DSA)技术在颅内动脉瘤诊断和介入治疗中的应用价值。方法对51例蛛网膜下腔出血的患者进行常规全脑血管DSA检查后,再行旋转DSA采集数据,利用工作站进行三维重建。分析3D-DSA与常规DSA对颅内动脉瘤显示的差异,评价3D-DSA对介入栓塞治疗的指导意义。结果常规DSA检出脑动脉瘤34例,经应用旋转DSA及三维重建后检出46例,其中35例进行介入血管内栓塞治疗,栓塞效果良好,11例行手术夹闭治疗。结论3D-DSA可显著提高颅内动脉瘤的检出率,能够直观清楚地显示动脉瘤详细全面的解剖信息,指导制定治疗计划,在脑动脉瘤的诊断和介入治疗中具有重要的价值。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号