 共查询到20条相似文献,搜索用时 125 毫秒
1.
程玲艳  崔娟莲  段宣初 《眼科》2011,20(1):33-37
目的探讨动态轮廓眼压计(DCT)与Goldmann压平眼压计(GAT)及非接触眼压计(NCT)测量眼压的准确性,并比较三种眼压计测量结果与中央角膜厚度(CCT)的相关性。设计前瞻性、比较性病例系列。研究对象连续选取90例(90眼)10~76岁正常人。方法采用KONAN非接触式角膜内皮镜测量CCT后,对所有入选者单眼以随机顺序采用Pascal型DCT、GAT及Topcon型NCT测量眼压。测量结果两两比较,并将眼压值与CCT进行直线回归分析。主要指标眼压值,Pearson相关系数。结果 90例正常人DCT眼压平均值(17.33±2.71 mm Hg)明显高于GAT(14.27±2.81 mm Hg)(P=0.000)及NCT(14.67±2.93 mm Hg)(P=0.000),平均差异分别为(3.06±2.01)mm Hg和(2.67±2.20)mm Hg;GAT与NCT之间平均差异为(-0.39±2.29)mm Hg(P=0.105)。DCT与GAT眼压值之间相关系数r=0.736(P=0.000);与NCT眼压值之间相关系数r=0.699(P=0.000)。GAT、NCT眼压值与CCT均明显相关(r=0.370,P=0.000;r=0.508,P=0.000);DCT眼压值与CCT无明显相关性(r=0.051,P=0.639)。DCT和GAT的差值与年龄无明显相关性(r=0.064,P=0.052)。结论 DCT测量的眼压值虽高于GAT及NCT,但不受CCT的影响,可能较GAT和NCT测量的眼压值更接近真实值。  相似文献   

2.
目的比较Diaton眼压计(DT)与非接触式眼压计(NCT)测量眼压的差异。方法分别使用DT和NCT测量患者眼压,对测量值进行统计学分析,多元相关分析研究眼压测量值与年龄、角膜曲率、等效球镜度、中央角膜厚度之间的相关性。结果 DT与NCT的平均眼压测量值分别为(13.81±3.27)mmHg和(15.80±3.48)mmHg,差异有统计学意义(P〈0.05),二者测量值的相关系数r=0.438,P〈0.05,两种眼压计的测量差值随中央角膜厚度增加而升高;将所有患者依照中央角膜厚度分为3组,NCT测量值在3组间有显著差异,而NCT测量值在3组间无差异;NCT测量值与年龄和中央角膜厚度呈正相关,而DT测量值与年龄、角膜曲率、等效球镜度、中央角膜厚度均不相关。结论 Diaton眼压计测量值不受年龄和中央角膜厚度影响,与非接触式眼压计测量值呈正相关,可应用于临床普查和诊断。  相似文献   

3.
目的探讨中央角膜厚度(CCT)对Goldmann眼压计与非接触式眼压计(NCT)眼压测量值的影响。方法分别用Goldmann眼压计与NCT测量83例(83只眼)正常人的眼压,采用光学相干断层扫描仪(OCT)测量CCT。采用配对T检验比较Goldmann眼压计与NCT眼压计眼压测量值的差异,采用线性相关分析方法分析两种眼压计眼压测量值之间的相关关系,并分析CCT对两种眼压计眼压测量值的影响。结果Goldmann眼压计测得的眼压平均值为(13.46±2.93)mmHg,NCT测得的平均值为(12.29±3.47)mmHg,两者之间差异有显著性(t=5.831,P〈0.001);两种眼压计眼压测量值呈正相关(r=0.852,P〈0.001)。Goldmann眼压计眼压测量值和NCT眼压测量值均与CCT呈正相关,r值分别为0.424(P〈0.001)和0.568(P〈0.001)。Goldmann眼压计眼压测量值与NCT眼压测量值的差值与CCT呈负相关(r=-0.402,P〈0.001)。去除CCT因素影响后,两种眼压计眼压测量值的残差差异无显著性(t=-0.272,P=0.787)。结论Goldmann眼压计与NCT眼压计眼压测量值均受CCT的影响,CCT对NCT眼压测量值的影响更大;两种眼压计眼压测量值的差异可能来源于个体CCT的差异。  相似文献   

4.
目的探讨中央角膜厚度和角膜曲率对轮廓动态眼压计以及非接触式眼压计眼压测量结果的影响。方法接受准分子激光原位角膜磨镶术(LASIK)的近视患者27例(54只眼),分别于术前和术后第4周使用非接触式眼压计(NCT)和动态轮廓眼压计(DCT)进行眼压测量。多元线性相关分析研究NCT、DCT测量值和角膜曲率及角膜中央厚度(CCT)之间的相关性。结果LASIK术后NCT测量值降低,而DCT测量值和术前比较差异则无统计学意义。角膜曲率、CCT和NCT读数呈线性相关,而与DCT读数无关。结论DCT测量眼压不受角膜曲率和中央角膜厚度影响,因此更适合于正常眼以及曾经接受角膜屈光手术眼的眼压测量。  相似文献   

5.
目的比较动态轮廓眼压计(DCT)和Pentacam眼压校正系统在LASIK手术前后的应用价值。方法对行LASIK手术的65例(129眼)于术前和术后1个月用Pentacam系统测量中央角膜厚度(CCT)和角膜曲率(CCV)后,分别用非接触眼压计(NCT)和DCT测量眼压,并用Pentacam系统的Ehlers、Shah、Dresden、Orssengo/Pye和Kohlhaas5种眼压校正方法对NCT眼压值进行校正,将测量结果进行统计学分析。结果DCT值在手术前后均最高,DCT值和Ehlers法校正值术前与术后比较差异无统计学意义(P〉0.05);其他方法眼压校正值术前与术后比较,差异均有统计学意义(P〈0.01),术前与术后各组眼压值之间呈正相关性;DCT测量值在LASIK手术前后与CCT、CCV均无相关性(P〉0.05),Pentacam的各组校正值在术前和术后均与CCT和CCV有密切的关系。结论DCT测量眼压不受CCT和CCV的影响,可作为LASIK术后眼压测量的首选方法,Pentacam系统Ehlers校正法是对LASIK术后准确测量眼压的有力补充。  相似文献   

6.
目的评价动态轮廓眼压计(DCT)与Goldmann压平眼压计(GAT)测量值之间的关系,寻找DCT眼压测量值的影响因素;分析DCT所测眼压脉动振幅(OPA)与DCT眼压值、中央角膜厚度(CCT)、角膜屈光力(CCV)、眼轴长度(AL)、前房深度(ACD)、收缩压(SBP)、舒张压(DBP)和心率(HR)的关系。方法分别测量正常人60例60眼的DCT眼压、GAT眼压、CCT、CCV、AL、ACD以及HR、SBP、DBP等指标,比较GAT、DCT2种眼压计测量的相关性及DCT测量值的影响因素。结果 DCT与GAT所测眼压平均值分别为(16.04±2.57)mmHg和(14.20±2.93)mmHg。DCT眼压值较GAT眼压值高,差异有统计学意义(t=6.454,P〈0.01)。DCT眼压值与GAT眼压值呈正相关(r=0.684,P〈0.01)。DCT眼压值与CCT不相关(r=0.212,P=0.105),GAT眼压值与CCT呈正相关(r=0.291,P=0.024)。60例正常人的OPA均值为(2.50±0.89)mmHg,OPA与年龄、DCT眼压值、CCT、SBP、DBP、HR均不相关(P〉0.05),与CCV呈正相关(r=0.343,P=0.007)。结论在正常人群中DCT眼压值与GAT眼压值有较好的相关性,DCT的眼压测量值不受CCT、CCV等因素的影响。DCT眼压值、CCT、SBP、DBP、HR等对OPA无明显影响。  相似文献   

7.
目的 比较动态轮廓眼压计(DCT)和非接触眼压计(NCT)在不同屈光度患者中测量值的差异,并探讨屈光手术对DCT和NCT测量值的影响.方法 226眼按不同屈光度分3组:轻度组31眼(-1.25D~-3.00D),中度组135眼(-3.12D~- 6.00D),高度组60眼(-6.12D~- 10.625D),各组分别用NCT和DCT测量眼压,并比较不同屈光度与两种眼压计读数的差异关系.结果 屈光手术前总NCT值与屈光度无相关关系(r=0.033,P=0.626).通过控制屈光度分级的影响进行偏相关分析,DCT与屈光度的相关系数为(r=0.079,P=0.240),且无统计学意义.术前轻度组NCT和DCT测量值差异无统计学意义(t=-1.091,P=0.284);中度组和高度组的NCT和DCT值有统计学意义(t=-2.687,P=0.008;t=-3.791,P=0.000).术后各组比较:NCT和DCT测量值均有统计学意义(t=-14.493,P=0.000;t=-28.505,P=0.000;t=-24.557,P=0.000).结论 DCT测量眼压结果 不受角膜厚度、角膜曲率及眼轴长度的影响,DCT值与患眼的屈光度也无相关性,更适应于角膜屈光手术后患眼眼压的测量和评估,但对高度近视眼手术后仍应警惕眼压被低估的可能.  相似文献   

8.
角膜厚度对两种眼压测量方法的影响   总被引:6,自引:2,他引:4  
目的 比较非接触眼压计 (non -contacttonometer ,NCT)和Goldmann压平眼压计测量眼压的差异 ,并分别探讨中央角膜厚度 (centralcornealthickniss ,CCT)对这两种测量方法的影响。方法 对 1 0 8例拟接受PRK或LASIK手术的患者行CCT ,NCT和Goldmann压平计眼压测量。结果NCT和Goldmann压平眼压计测得的眼压均值具有显著性差异 (F =89 .70 4 4,P <0 . 0 1 )。CCT与NCT和Goldmann压平眼压计测量值呈正相关 ,相关系数分别是r =0. 4 96 0 (t =8 .356 3,P <0 .0 0 1 )和r =0 . 2 1 1 3(t =3. 1 6 2 3,P <0 .0 0 1 )。结论 NCT和Goldmann压平眼压计测量眼压值有差异 ,NCT测量值大于Goldmann压平眼压计 ,CCT对NCT的影响大于Goldmann压平眼压计。  相似文献   

9.
目的:验证动态轮廓眼压计(DCT)的临床性能。方法:对81例143眼青光眼及可疑病例青光眼患者用DCT测量眼内压(IOP);132眼同时用Goldmann压平眼压计(GAT)测量眼压,部分病例同时用NIDEKUP-1000型角膜测厚仪测量中央角膜厚度(CCT)。GAT与DCT测量结果采用配对t检验,GAT、DCT测量值与CCT的关系及DCT测量值与眼脉动振幅(OPA)的相关关系采用Spearman双变量相关分析。结果:①DCT和GAT测得的眼压均数分别为(18.6±3.9)mmHg和(17.4±4.1)mmHg;DCT测得的眼压值高于GAT,其差值均数为(1.1±2.3)mmHg;两种眼压计测得的眼压值呈正相关(r=0.83,P<0.01)。②116眼同时完成了DCT眼压测量及CCT测量,两者相关系数r=0.03,P=0.77;113眼同时完成了GAT眼压测量及CCT测量,两者相关系数r=0.28,P=0.003。③143眼同时记录了DCT眼压值和眼脉动振幅(OPA),其均数分别为(18.6±3.9)mmHg和(2.6±1.1)mmHg,两者的相关系数r=0.32,P<0.01。结论:以上结果初步证实:①DCT眼压计测量值与GAT眼压测量值高度相关,但DCT测量值略高于GAT测量值,提示DCT可用于临床诊断。②DCT测量值与CCT不相关,GAT测量值与CCT显著相关,提示DCT在青光眼诊断中有独特优势。③DCT测量的OPA与IOP值显著相关,相关的机制及临床意义有待探讨。  相似文献   

10.
赵剑  孟觉天 《国际眼科杂志》2011,11(10):1726-1729
目的:比较非接触式眼压计(NCT)、Goldmann压平式眼压计(GAT)、动态轮廓眼压计(DCT)和Pentacam三维眼前节分析系统四种方法检查眼压的差异,并研究它们与中央角膜厚度(CCT)和中央角膜曲率(CCV)的关系。方法:对拟行LASIK手术的143例286眼患者用Pentacam系统测量CCT和CCV后,分别用NCT,GAT和DCT测量眼压,并用Pentacam系统的Ehlers,Shah,Dresden,Orssengo/Pye和Kohlhaas5种眼压校正方法对NCT眼压值进行校正,将测量结果进行方差分析、相关性及线性回归分析。结果:DCT值最高,DCT与其他方法之间均有显著性差异(P<0.01);GAT与DCT,Kohlhaas,Shah之间有差异(P<0.05),与其他方法之间无差异;各组眼压值之间有较好的相关性,GAT与DCT的相关性最强(r=0.702);NCT受CCT影响最大,GAT受CCV影响最大,DCT,Dresden,Orssengo/Pye,Shah与CCT和CCV均不存在相关性(P>0.05)。结论:对CCT和CCV正常的健康人群进行青光眼筛查时建议使用压平式眼压计,对可疑的患者,尤其是CCT和CCV偏离正常的患者,宜进一步行DCT检查或者用Pentacam系统进行眼压校正。  相似文献   

11.
目的:比较Goldmann眼压计、非接触式眼压计与Schiotz眼压计对维吾尔族、汉族大学生眼压测量值结果。

方法:横断面研究。分别采用Goldmann眼压计、非接触式眼压计与Schiotz眼压计测量维吾尔族、汉族大学生眼压。比较两族整体间、同族不同性别间、不同眼别间三种眼压计测得的眼压值。

结果:相同眼压计对维吾尔族及汉族大学生眼压测量值差异有统计学意义(P<0.05); 相同眼压计对同族不同性别间眼压测量值差异无统计学意义(P>0.05); 相同眼压计对不同眼别间眼压测量值差异无统计学意义(P>0.05),汉族学生比维吾尔族学生眼压测量值高(P<0.05),非接触式眼压计比Goldmann眼压计眼压测量值偏高(P<0.05),非接触式眼压计比Schiotz眼压计眼压测量值要小(P<0.05)。

结论:同一眼压测量仪对同族不同性别间及不同眼别间无差异,汉族学生比维吾尔族学生眼压测量值高,Schiotz眼压计眼压值测量结果显著高于非接触式眼压计,而非接触式眼压计眼压测量值高于Goldmann眼压计。  相似文献   


12.
A review of the literature and a comparative study against Goldmann applanation tonometers suggests that the non-contact tonometer is reliable for measuring intraocular pressures within the normal range. In addition, the non-contact tonometer eliminates the need for corneal contact and topical anesthesia, thereby avoiding the potential problems of corneal abrasion, spread of infection, and drug reactions. The instrument can be used reliably by paramedical personnel and has particular value in mass screening and possibly in studies of topical antiglaucoma drugs. The non-contact tonometer is less reliable in patients with elevated intraocular pressure, since comparative studies against the Goldmann applanation tonometers have shown poorer correlations in the higher pressure ranges. The instrument is also limited by an abnormal cornea or poor fixation, which may interfere with accurate pressure measurements. Furthermore, the non-contact tonometer is less portable than many tonometers and more expensive than most.  相似文献   

13.
Tono-Pen眼压计临床应用评价   总被引:7,自引:0,他引:7  
目的 评价Tono -Pen眼压计的临床应用价值。方法  93例青光眼患者的 93眼纳入本研究 ,分别进行了Goldmann眼压计和Tono -Pen眼压计的测量。对两种眼压计的测量结果进行比较并评价Tono -Pen眼压计的特异度与灵敏度。结果 两种眼压计测量值相差范围 -12~ 8mmHg ,差值的绝对值≤ 2mmHg占 61 3 % ,≤ 3mmHg为 75 3 % ,≥ 7mmHg者 5 4% ,总体相关系数 0 944(P <0 0 0 1) ,眼压≤ 2 1mmHg ,Tono -Pen眼压计偏高估计眼压 0 70± 2 3 1mmHg (P <0 0 5 ) ,2 2~3 0mmHg ,Tono -Pen眼压计偏低估计眼压 1 71± 3 15mmHg (P <0 0 5 ) ,>3 0mmHg ,两种测量手段所得结果无差异 (P >0 0 5 )。Tono -Pen眼压计的特异度与灵敏度分别为 93 6%和 84 8%。结论Tono -Pen眼压计可用于青光眼的筛查 ,但不适合用于其诊断和随访。  相似文献   

14.
Pulsair眼压计对正常眼压范围进行检测。并对左、右眼;男与女;不同年龄组的眼压值进行比较。用Pulsair眼压计和Perkins眼压计对正常组和青光眼组的坐位眼压进行比较。用Pulsair眼压计对坐、卧位眼压差进行检测。证明Pulsair眼压计准确、可靠且使用方便、安全。  相似文献   

15.
The precision and speed of two non-contact tonometers were examined and compared. The Goldmann applanation tonometer was used as the standard for precision. On the average the results obtained with the non-contact tonometers were not significantly different from those obtained with the Goldmann tonometer. The variation in the values obtained with the non-contact tonometers was greater. The speed of measurement differed between the two non-contact tonometers.  相似文献   

16.
目的::对比分析 Goldmann 压平式眼压计( Goldmann applanation tonometer, GAT)和非接触眼压计( non-contact tonometer,NCT)测量青光眼患者眼压的结果,寻找其规律性。方法:分别使用GAT和NCT测量108例206眼青光眼患者的眼压。结果:青光眼患者108例206眼的平均眼压:GAT测量为29.77±10.27mmHg,NCT测量为24.59±8.58mmHg,两者比较存在显著性差异(P<0.01),而且眼压越高,差异性越显著。结论:NCT 测量值较 GAT 测量值低,眼压越高,差值越大。建议使用GAT检查青光眼患者的眼压,以免漏诊和贻误治疗。  相似文献   

17.
目的 比较应用爱科回弹式眼压计(iCare Rebound Tonometer,RBT)与非接触眼压计(non-contact tonometer,NCT)测量正常人群眼压结果的差异,并讨论RBT在眼科临床中的应用.方法 对131例(262只眼)分别用RBT和NCT在同一体位进行眼内压(intraocular pressure,IOP)的测量,对所得数据进行配对t检验及相关性分析.结果 NCT所测眼压平均值为(13.69±6.01)mmHg,RBT所测眼压平均值为(14.05±4.09)mmHg,NCT和RBT测得的眼压值无显著差异(P=0.23),两种眼压测量方式具有良好的相关性(相关系数0.56).结论 在进行正常人群高眼压筛选中,RBT和NCT测得眼压值无显著差异,有良好的相关性,RBT在进行青光眼的初步筛选中比NCT更为方便、快捷,值得推广.  相似文献   

18.
AIM: To analyze the correlation of Goldmann applanation tonometer (GAT), I-Care tonometer and Tono-Pen tonometer results in young healthy persons, and to investigate the influence of central corneal thickness (CCT) on intraocular pressure (IOP) measurements recorded with these tonometers. METHODS: We conducted a pilot clinical study in 78 eyes of 78 subjects aged 22-28 years old (44 women and 34 men; mean age 23.8±1.19y). IOP was measured using GAT, I-Care and Tono-Pen tonometers, followed by measurements of CCT. Statistical analysis was performed using SPSS 20.0. RESULTS: The mean IOPs and standard deviation (±SD) for GAT, I-Care and Tono-Pen were 15.62±2.281 mm Hg, 16.29±2.726 mm Hg and 16.32±2.393 mm Hg, respectively. The mean CCT was 555.15±29.648 μm. Clear positive correlations between GAT and I-Care, GAT and Tono-Pen, and I-Care and Tono-Pen tonometers were found (r=0.867, P<0.001; r=0.861, P<0.001; r=0.915, P<0.001, respectively). In comparison between devices, Bland–Altman analysis showed a significant mean difference (MD) in the measurements by GAT and I-Care of ?0.679 mm Hg and by GAT and Tono-Pen of ?0.705 mm Hg ( P<0.001), but there was no significant difference between I-Care and Tono-Pen ( P>0.05). Both non-gold standard tonometers were affected by CCT; that is, both I-Care and Tono-Pen tonometer values were significantly higher with higher CCT means (>555 μm; MD=?1.282, P<0.001; MD=?0.949, P<0.001, respectively) compared with GAT. CONCLUSION: Both I-Care and Tono-Pen tonometers overestimated IOP compared with the GAT values. Either the I-Care or Tono-Pen tonometer could be used instead of GAT because there was no significant difference between their results. Higher CCT values (>555 μm) were associated with overestimated IOP values.  相似文献   

19.
目的:采用PASCAL动态轮廓眼压计(dynamic contour to-nometer,DCT)及KEELER非接触眼压计(non contact to-nometer,NCT)对一组健康青年昼夜眼压进行监测,描述其波动规律,并比较两种方法异同。方法:以PASCAL动态轮廓眼压计对一组19~22岁健康青年27例(54眼)进行24h眼压监测;以KEELER非接触眼压计对一组19~22岁健康青年84例(168眼)进行24h眼压监测。测量自早晨08∶00开始至次日凌晨06∶00,每隔2h为一个观察时间点,每个时间点测量3次,以平均值作为该时间点眼压。结果:DCT法与NCT法所测得的眼压平均值分别为15.76±2.37mmHg和13.77±4.33mmHg,DCT组眼压均值的最高值出现在08∶00,最低值出现在20∶00;NCT组眼压均值的最高值出现在06∶00,最低值出现在22∶00。DCT组双眼眼压波动值分别为:左眼4.56±1.19mmHg,右眼4.12±1.21mmHg;NCT组双眼眼压波动值分别为:左眼4.71±2.23mmHg,右眼5.00±1.50mmHg,两种方法左右眼间眼压值差异无统计学意义(F=0.668,P=0.415),男女眼压值差异无统计学意义(F=1.459,P=0.229),12个时间点之间眼压值差异有统计学意义(F=64.407,P=0.000),且变化趋势呈为二次抛物线,两种方法随时间变化趋势有统计学意义(F=16.615,P=0.000)。结论:正常青年眼压呈昼夜节律变化,于白昼结束时最低,夜晚结束时最高。不同的测量方法在各时间点所得测量值及昼夜变化趋势上存在差异,且采用动态轮廓眼压计在多个时间点上均比采用非接触眼压计所测值高。临床上在应用眼压作为原发性青光眼诊断和疗效判断时,应注意测量时间及方法选择上的差别。  相似文献   

20.
目的:比较非接触眼压计(non-contacttonometer,NCT)与Goldmann压平眼压计(GAT)测量眼压的差异,以评价非接触式眼压计在临床青光眼患者及疑似青光眼患者中的的应用价值。方法:志愿者174例348眼分别由专人进行非接触眼压计(NCT)与Goldmann压平眼压计眼压测量。结果:非接触眼压计(NCT)的测量结果低于Gold-mann压平眼压计且差异有显著性(19.6vs23.4,P<0.05),两者相关系数为r=0.783,差异在眼压>30mmHg组更为明显,相关系数为0.334。结论:非接触眼压计(NCT)可以用于临床普查,在青光眼的临床工作中建议使用Goldmann压平眼压计矫正。  相似文献   