首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 171 毫秒
1.
目的 探讨负压真空垫固定双下肢法与自制泡沫脚垫固定双脚踝法固定体位方式在直肠癌IMRT中对摆位误差的影响。方法 2014年选取12例直肠癌患者随机均分成A、B组,A组患者负压真空垫固定双下肢法,B组患者采用自制塑料泡沫脚垫固定双侧脚踝法。采集108人次(A、B组各54人次)治疗前后KV-CBCT图像行灰度平移误差配准,成组t检验两组患者在左右方向(x轴)、上下方向(y轴)、前后方向(z轴)的摆位误差。结果 两组患者y轴摆位误差相近[(2.13±0.64) mm∶(2.61±1.17) mm,P=0.399];x轴摆位误差A组低于B组[(1.51±0.28) mm∶(2.70±1.05) mm,P=0.039],A、B组误差率分别7.41%、42.59%;z 轴上A组也低于B组[(1.10±0.29) mm∶(2.37±0.71) mm,P=0.002],A、B组误差率分别1.85%、35.19%。结论 直肠癌放疗摆位采用负压真空垫固定双下肢法有效避免了双下肢左右平移和内外旋转,从而减少摆位误差,比自制泡沫脚垫固定双脚踝法的精确性更高。  相似文献   

2.
目的 探讨应用胸腹平架固定装置的体侧与上举两种体位方式放疗时,肺癌、食管癌锁骨上区摆位误差的差异。方法 回顾性分析2020—2021年在本中心行三维放疗的Ⅰ-Ⅳ期肺癌和食管癌患者资料,比较两种体位方式(双臂置于身体两侧即体侧组和双臂交叉抱肘置于额前即上举组)的摆位误差。结果 共纳入 56例患者,其中体侧组 31例(55%),上举组 25例(45%)。全组共进行了424次CBCT验证,两组整体摆位误差在X、Y、Z方向上相近(均 P>0.05)。体侧组胸锁关节摆位误差在XRZ方向上显著小于上举组[(0.163±0.120) cm∶(0.209±0.152) cm,P=0.033和0.715°±0.628°∶0.910°±0.753°,P=0.011]。体侧组肩锁关节摆位误差在YZRZ方向上显著小于上举组[(0.233±0.135) cm∶(0.284±0.193) cm,P=0.033和(0.202±0.140) cm∶(0.252±0.173) cm,P=0.005及0.671°±0.639°∶0.885°±0.822°,P=0.023]。体侧组在胸锁关节的X (0.45cm∶0.54cm)、Y (0.54cm∶0.65cm)方向以及肩锁关节的Y (0.59cm∶0.78cm)、Z (0.53cm∶0.72cm)方向需要的靶区外放范围更小。结论 对于需要行锁骨上区照射的肺癌和食管癌患者,体侧组较上举组的摆位误差和靶区外放范围更小。临床上需要综合考虑放疗精确性和肢体额外照射,选择合适的体位。  相似文献   

3.
目的 探讨使用颈胸一体架(膜)对乳腺癌术后放疗患者体位固定的效果。方法 前瞻性入组32例乳腺癌术后放疗患者,均使用颈胸一体架(膜)进行体位固定,采用调强放疗技术照射乳腺/胸壁和锁骨上下区,并在放疗中进行锥形束CT(CBCT)位置验证,分别配准乳腺/胸壁靶区和锁骨上下区靶区。对239次CBCT图像的摆位误差和上下靶区位置一致性进行分析。结果 左右、头脚、腹背方向乳腺/胸壁的平移摆位误差分别为(1.84±2.36)、(1.99±2.48)、(1.75±1.86)mm,锁骨上下区的平移摆位误差分别为(1.98±2.44)、(1.98±2.48)、(1.71±1.79)mm。每个病例每次CBCT扫描的乳腺/胸壁与锁骨上下区平移误差的差值在x、y、z方向分别为(0.38±0.66)、(0.07±0.41)、(0.45±0.92)mm。结论 乳腺癌术后放疗患者采用颈胸一体架(膜)进行体位固定,摆位误差小,乳腺/胸壁和锁骨上下区靶区位置有很好的一致性。  相似文献   

4.
目的 运用KV级CBCT比较聚氨酯发泡胶结合翼板个体化塑形与负压真空袋固定在肺癌放疗中体位固定的精确度。方法 对2015—2016年在中山大学肿瘤防治中心接受胸部放疗的肺癌患者随机选取两种固定方法的患者,其中负压真空袋组 20例,聚氨酯发泡胶结合翼板个体化塑形组 19例。1 次/周CBCT图像与计划CT图像进行匹配后分别记录左右、上下和前后方向摆位误差、3D矢量位移及摆位时间,根据2.5∑+0.7σ计算PTV外放边界。成组t检验两组数据差异。结果 发泡胶组和真空袋组线性摆位误差x轴向分别为(1.80m±1.48) mm和(1.90±1.41) mm (P=0.46),y轴向分别为(2.54±1.79) mm和(3.19±2.14) mm (P=0.03),z轴向分别为(2.14±1.75) mm和(2.25±1.75) mm (P=0.35);旋转摆位误差在Rx向分别为1.15°±0.76°和1.15°±0.85°(P=0.50),Ry向分别为0.71°±0.60°和0.72°±0.43°(P=0.45),Rz向分别为0.62°±0.54°和0.46°±0.30°(P=0.06)。发泡胶组和真空袋组在x、y、z轴向PTV所需外扩边界分别为5.56、8.57、7.02 mm和5.62、9.27、7.23 mm。3D矢量位移>5 mm者,发泡胶组为40%,真空负压袋组为45%。结论 采用聚氨酯发泡胶结合翼板个体化塑形固定可在一定程度上减少肺癌放疗患者在上下方向摆位误差并减少PTV外扩边界。  相似文献   

5.
目的 使用CBCT测量食管癌IGRT分次内误差,评价其对靶区和周围OAR剂量的影响。方法 应用CBCT采集 23例胸段食管癌放疗前后摆位图像,获取分次内误差。将分次内误差模拟治疗计划2和计划3,与原始计划1比较,分析其对靶区和OAR剂量学影响,并用单因素方差分析和配对t检验。结果 胸上段、胸中段、胸下段食管癌IGRT分次内平均误差在左右方向分别为(1.2±1.5)、(1.0±1.0)、(1.0±1.0) mm (P=0.138),在上下方向分别为(1.2±1.0)、(1.1±1.0)、(1.2±1.0) mm (P=0.656),在前后方向分别为(1.3±1.1)、(1.2±1.0)、(0.8±0.7) mm (P=0.003)。全部患者3 mm内误差发生频率在左右、上下、前后方向分别占95.2%、94.5%、93.9%。计划3与计划1相比,GTV V100%下降5.55%,有 3例患者PTV D95%下降超过原始计划处方的5%。计划3中全肺 V30为(15.24±2.24)%,低于计划1的(15.67±2.28)%(P=0.033)。计划2中 4例脊髓>4500 cGy (Dmax为4517.2 cGy),计划3中 19例脊髓>4500 cGy (Dmax为5045.2 cGy)。结论 IGRT分次内误差对患者靶区剂量分布有一定影响。脊髓为串行器官,对分次内误差相对敏感,可能会导致部分患者脊髓超过最大耐受量。  相似文献   

6.
目的 探讨辅助体表标记摆位方法是否可以减少胸腹部肿瘤超重患者放疗摆位误差。方法 入组2018年1-12月在福建医科大学附属第一医院行放疗的胸腹部肿瘤超重患者60例,随机均分成两组:A组用常规体表标记摆位,B组用常规体表标记+辅助体表标记摆位,均采用头体一体式体位固定板+热塑体膜固定;治疗前行锥形束CT扫描并在线自动匹配,记录各方向平移摆位误差数据,两组摆位误差比较采用t检验。结果 A组和B组在左右、头脚、腹背方向的摆位误差分别为(4.47±2.91) mm和(2.97±1.68) mm (P<0.001)、(5.43±2.61) mm和(3.21±1.62) mm (P<0.001)、(3.87±2.40) mm和(2.59±1.57) mm (P<0.001)。结论 采用辅助体表标记摆位方法可以减少胸腹部肿瘤超重患者的摆位误差,能提高治疗摆位重复性。  相似文献   

7.
目的 应用IGRT技术,探讨肺部恶性肿瘤患者大分割放疗过程中分次内体位移动情况及相关影响因素。方法 选择江苏省肿瘤医院收治的 96例肺部恶性肿瘤接受大分割治疗的患者。每次治疗前常规行千伏级CBCT扫描并在线配准,校正误差后进行治疗。治疗后再次行CBCT扫描并配准,记录治疗后患者左右、上下、前后方向上的体位变化,应用多元线性回归分析相关影响因素与治疗后体位偏差的关系。结果 上下和前后方向随着分割序数增大分次内体位偏差减小(P=0.000);左右方向随治疗时间延长则分次内移动度增大(P=0.010),体重较大者则移动度较小(P=0.003)。相对于真空体膜,采用热塑网膜固定分次内左右移动度明显增大(P=0.009)。结论 肺部肿瘤大分割放疗分次内存在一定体位误差;这种误差不同方向上有不同的影响因素。改进相关因素,可减少分次内体位误差,提高治疗精度。  相似文献   

8.
目的 探讨乳腺癌保乳术后调强放疗中不同体重指数(Body mass index,BMI)患者体位固定方式与摆位误差的相关性。方法 回顾性分析接受调强放疗的117例保乳术后乳腺癌患者的临床资料。根据放疗时患者不同的体位固定方式分为A、B两组,A组患者(57例)为真空袋组,B组患者(60例)为乳腺托架组。根据患者的BMI指数分为1组(<18.5 kg/m2)、2组(18.5~23.9 kg/m2)、3组(24~27.9 kg/m2)和4组(≥28 kg/m2)。比较不同BMI分组的乳腺癌患者体位固定方式与摆位误差的关系。结果 A组患者左右方向(X轴)总摆位误差小于B组(P<0.05);A3、A4组患者X及Y轴摆位误差小于B3、B4组(P<0.05)。在前后方向(Z轴)上,A组和B组之间的差异均无统计学意义(P>0.05)。结论 保乳术后接受调强放射治疗的乳腺癌患者BMI指数对摆位误差具有影响,对于超重患者(BMI≥24 kg/m2)更宜选用真空袋固定方式。  相似文献   

9.
目的 分析脑转移患者立体定向放疗ExacTrac X线图像,计算分次间和分次内摆位误差及残余误差,分析进行逐弧位置验证的必要性。方法 通过对过去2年在本中心采用头部立体定向放疗的脑转移瘤病例的回顾性分析,配准其数字重建图像和ExacTrac正交kV级验证图像,计算患者3个方向的平移误差和旋转误差。数据包含分次间摆位误差、分次内摆位误差和残余误差。结果 75例116个病灶进行了337次头部立体定向放疗。分次间、分次内平移摆位误差分别为左右方向x (0.93±0.86)、(0.15±0.59) mm,头脚方向y (1.83±1.27)、(0.25±0.73) mm,腹背方向z (0.96±0.80)、(0.14±0.56) mm;分次间、分次内旋转摆位误差分别为矢状面Rx (0.65°±0.62°)、(0.19°±0.40°),横断面Ry (0.97°±0.94°)、(0.13°±0.25°),冠状面Rz (0.92°±0.71°)、(0.10°±0.29°)。残余平移误差左右、头脚、腹背方向分别为(0.06±0.23)、(0.08±0.24)、(0.08±0.22) mm;残余旋转误差矢状面、横断面、冠状面分别为(0.12°±0.27°)、(0.09°±0.18°)、(0.06°±0.19°)。337次分次间摆位误差99.1%超过误差阈值(0.7 mm,0.7°)需要至少校正1次;1 006组分次内摆位误差33.6%在治疗床转到位验证无需误差校正,66.4%需要校正至少1次。结论 头部立体定向放疗患者要重视分次间摆位误差和分次内摆位误差,进行逐弧体位验证是非常必要的。  相似文献   

10.
目的 初步探究发泡胶与真空垫在乳腺癌保乳根治术后IMRT体位固定中的精度差异。方法 选取2017-2018月间本院收治保乳术后全乳大分割IMRT (42.56Gy分16次)的乳腺癌患者40例,随机均分为发泡胶组和真空垫组固定。分次治疗前使用瓦里安Trilogy机载图像验证系统拍摄患者正侧位照片,并与计划系统重建的数字重建图像进行匹配验证获得两组患者在左右、头脚、腹背方向摆位误差。每名患者验证10次,共获得400组数据。采用独立样本t检验获得组间摆位误差,并计算临床靶体积至计划靶体积分次间摆位误差的外扩值。结果 发泡胶固定组与真空垫组在左右、头脚、腹背方向摆位误差分别为(1.63±1.29) mm与(1.83±1.61) mm (P=0.18)、(1.46±1.51) mm与(2.26±2.03) mm (P=0.00)、(1.30±1.35) mm与(1.91±1.67) mm (P=0.00)。临床靶体积至计划靶体积分次摆位误差的外扩值分别为2.19、2.51、1.57mm与2.40、3.97、2.63mm。结论 两种固定方式均满足临床要求,但初步证明发泡胶固定摆位精度与重复性均优于真空垫组。  相似文献   

11.
目的 探讨应用HT治疗多发转移瘤时合适的MVCT引导方案。方法 将48例采用HT的多发转移瘤患者按靶区分布情况分为头胸组(15例)、头盆组(15例)和胸盆组(18例)。于治疗分次内对各靶区分别行MVCT扫描,将所得图像与定位CT图像进行配准并记录摆位误差值。计算各CTV到PTV的外扩边界。配对t检验差异。结果 头胸组、头盆组、胸盆组患者摆位误差的两两比较显示,x轴分别为-0.15±1.25∶-0.21±2.34(P=0.71)、-0.16±1.31∶-1.29±3.72(P=0.00)、0.25±2.90∶-0.22±3.65(P=0.06),y轴分别为0.73±1.22∶1.56±2.54(P=0.00)、0.81±1.34∶3.20±3.90(P=0.00)、0.35±3.60∶0.38±3.78(P=0.87),z轴分别为0.93±1.44∶2.65±1.88(P=0.00)、1.24±1.75∶5.49±2.80(P=0.00)、1.95±2.81∶3.35±3.05(P=0.00)。3个组经过各自上段靶区修正后,各自下段靶区的外扩边界在三维方向上均有所减小,但均以y轴缩小最显著,分别为5.13∶4.01、9.17∶8.30、8.52∶7.13。结论 对于分离靶区的多发转移瘤的HT,不应单独使用任一部位的摆位误差值修正整体摆位误差,建议采用分次内不同部位进行引导的图像引导方案。  相似文献   

12.
The objective of this study was to evaluate set-up uncertainties using a portal imaging system in a population of inoperable non-small cell lung cancer. Twenty-one patients were treated by a conformal radiotherapy technique with a personalized immobilization cast. The beam was verified by comparison with a corresponding digitally reconstructed radiograph by superimposition of anatomical structures. One thousand eight hundred eighty three images were analyzed. The mean intrafraction and interfraction errors (±SD) were 2.17 mm and 0.9 ± 3.7 mm, 2.3 mm and 0.9 ± 3.1 mm, 3 mm and 0.7 ± 3 mm on the lateral (x), cranio-caudal (y) and anterior-posterior (z) axes, respectively. The mean systematic error was small, less than 1 mm, in all directions. The random errors were 2.5 mm, 2.4 mm, and 1.8 mm on the x, y, and z axes, respectively. No correlation between errors and the patient's height, weight, age, or sex was found. Set-up errors accuracy depending on practices, each institution should review their own treatments to quantify and reduce set-up errors in clinical practice.  相似文献   

13.
Catalyst HD和皮肤标记线肺癌SBRT摆位精度比较   总被引:1,自引:0,他引:1  
目的 比较光学表面引导放疗系统Catalyst HD和皮肤标记线两种摆位方式在肺癌立体定向放疗(SBRT)中的摆位精度。方法 选取24例SBRT病例,均采用仰卧位和真空垫固定,分别利用Catalyst HD(A组)和皮肤标记线(B组)进行摆位,并通过CBCT和定位CT刚性配准方式获取床左右(x轴向)、升降(y轴向)、进出(z轴向)、床旋转(Rtn)、进出倾斜(Pitch)、左右转动(Roll)配准误差。结果 A组和B组六维度配准误差取绝对值后平均值±标准差依次为(0.13±0.12) cm和(0.25±0.19) cm、(0.26±0.15) cm和(0.13±0.11) cm、(0.23±0.19) cm和(0.35±0.29) cm、(0.43°±0.40°)和(0.80°±0.69°)、(0.48°±0.47°)和(0.79°±0.64°)、(0.62°±0.60°)和(0.88°±0.70°)。上述六组数据正态性检验除B组x轴向外均不服从正态分布,两组差异均有统计学意义(P<0.05)。两组数据中超限误差(>0.5cm/2°)差异也有统计学意义(P<0.05)。结论 Catalyst HD方式六维度配准误差均低于标记点方式(y轴向除外),Catalyst HD方式摆位精度优于传统标记点,具有较好临床应用价值。  相似文献   

14.
目的 在宫颈癌调强放疗中使用膀胱容积测量仪(BVI 9400)控制术前及术后宫颈癌患者的膀胱充盈度,比较靶区位移误差及其引起的照射剂量变化、膀胱充盈形态变化,研究膀胱充盈度的一致性在宫颈癌调强放疗中的重要性。方法 选取本院2018年内放疗的45例宫颈癌患者,分成A、B、C组,每组15 例。A组为未手术患者,B组为根治术后患者(两组疗前均使用BVI 9400监测膀胱尿量),C组随机选取患者采取自主憋尿未监测治疗前膀胱尿量。3个组患者疗前均行KV-CBCT扫描进行在线配准分析,计算在左右、头脚,腹背方向的靶区位移误差、处方剂量PTV覆盖体积百分比(V100)及百分比差值(ΔV100)。结果 左右、头脚,腹背方向平均位移误差A组分别为1.67、1.55、1.67 mm,B组分别为1.43、1.58、1.84 mm,C组分别为2.27、2.30、2.08 mm。V100、ΔV100 A组分别为96.96%、1.17%,B组分别为95.9%、1.29%,C组分别为94.02%、2.17%。结论 控制膀胱充盈度的一致性均能在一定程度上减小膀胱充盈程度不一致对误差产生的影响,保证了靶区位置的精度和靶区的照射剂量,对膀胱、小肠、直肠起到一定的保护作用,减轻宫颈癌患者放疗反应。  相似文献   

15.
目的 探讨MRI定位伽马刀治疗精度的检测与修正方法。方法 利用25点矩阵水箱对伽马刀治疗精度进行多点检测,将MRI定位坐标与经过CT定位曝光验证、治疗精度偏差<0.5 mm的坐标进行比对,发现MRI定位偏差的大小及图像有无变形,然后按偏差均值±图像几何畸变率给予修正,与标准坐标间无显著差异后再行胶片曝光验证。结果 所测3家医院MRI定位25点矩阵水箱的x、z坐标轴均无明显偏移,在y轴上存在的偏差分别为A院(-1.94±0.45) mm、B院(-2.22±0.29) mm和C院(-1.25±0.21) mm, A院在y轴上尚有1%的几何畸变率。以M表示偏差均值、GD为几何畸变率、Y0为矩阵中心点坐标,将25点坐标Y分别代入公式Y=(Y-M)+GD (Y0-Y)修正后,3家医院与标准坐标间均相近,验证片焦斑偏移也在0.5 mm内。结论 利用25点矩阵水箱进行伽马刀治疗精度多点检测和偏差的函数修正,可以明确MRI能否直接用于头部伽马刀定位。  相似文献   

16.
目的 CT模拟定位和放疗过程中均使用自制“倾倒式”治疗床进行摆位,探讨其减小摆位误差的可行性和有效性。方法 选取 2016年3-9月于肿瘤医院进行放疗的 22例胸腹部肿瘤患者,根据是否使用“倾倒式”治疗床随机分为2个组,每组 11例。试验组使用“倾倒式”治疗床实现患者由直立位转换至仰卧位,对照组采用常规的患者自主仰卧位。所有患者均在自主呼吸的状态下接受定位CT扫描,根据IGRT协作组的规范化建议进行图像配准。记录并分析CBCT扫描平移误差和旋转误差配准数据,根据“四参数模型”计算2个组摆位误差。结果 试验组x、y、z轴向平移误差和范围分别为(-0.012±0.128)、(0.272±0.123)、(0.089±0.105) cm和 0.29~0.70、0.23~0.70、0.14~0.53 cm,对照组的分别为(0.006±0.198)、(-0.108±0.396)、(-0.096±0.176) cm和 0.27~0.75、0.56~2.08、0.34~0.89 cm。结论 自制“倾倒式”治疗床可以提高胸腹部肿瘤放疗的摆位重复性,减少摆位误差,尤其是y轴向上的摆位误差。  相似文献   

17.
乳腺托架固定下全乳调强放疗CBCT测定摆位误差的研究   总被引:1,自引:0,他引:1  
目的 探讨乳腺癌保乳术后乳腺托架固定下全乳调强放疗的摆位误差和影响因素,明确临床靶体积外扩至计划靶体积的边界。方法 选取肿瘤医院2016-2017年间乳腺癌保乳术后接受全乳大分割调强放疗的患者30例,其中左侧乳腺癌患者15例,右侧乳腺癌患者15例。所有患者均采用乳腺托架体位固定。比较放疗计划系统图像与放射治疗期间锥形束CT的位移,确定摆位误差,并计算临床靶体积外扩至计划靶体积的边界。不同情况的摆位误差比较采用t检验。结果 全组患者共拍摄锥形束CT图像151套,平均每人(5.0±1.3)套。全组患者摆位误差在x、y、z轴的位移分别为(2.2±1.7)、(3.1±2.5)、(3.3±2.3) mm,CTV至PTV外扩边界分别为6.39、10.00、8.57 mm。放疗第1周摆位误差与后续治疗摆位误差在z轴方向有统计学差异[(3.7±2.5) mm和(2.6±1.6) mm,P=0.002],体重指数超重比正常患者在z轴方向摆位误差显著增大[(3.9±2.6) mm和(2.9±2.0) mm,P=0.033]。结论 乳腺癌保乳术后乳腺托架固定行全乳调强放疗时,推荐CTV至PTV的外扩边界为6~10 mm。建议增加放疗第1周的影像验证频率。  相似文献   

18.
目的 探究体表铅点标记辅助iSCOUT图像引导定位系统在乳腺癌调强放疗摆位误差监测及校正的应用价值,并计算PTV外放边界为临床提供参考。方法 选取2019年间福建医科大学附属协和医院行乳腺癌改良根治术后调强放疗的 25例患者,利用体表铅点标记辅助iSCOUT系统基于金标配准算法进行图像引导定位,分别记录3个平移方向左右(x)、头脚(y)和腹背(z)的初始摆位误差以及图像引导校正后的残余误差统计分析,进一步比较图像引导校正前后误差对计划剂量的影响,最后计算合理的计划靶体积(PTV)外放边界。结果 25例患者在体表铅点标记辅助iSCOUT图像引导定位下进行150次摆位验证,x、y、z轴向残余摆位误差绝对值分别为(1.53±0.96)、(1.30±0.99)、(1.34±0.92)mm,均小于初始误差值的(2.63±2.12)、(2.41±2.45)、(3.07±2.77)mm (P<0.001)。残余误差导致的剂量偏差百分比也比初始误差的小,在PTV的D98%、D2%、Dmax,心脏 Dmax、健侧乳腺 Dmax、患侧肺及双肺 Dmean等具有显著差异,与原计划偏差百分比分别由2.18%、3.19%、10.66%、8.75%、48.21%、10.50%、3.66%降低到0.38%、0.23%、2.31%、0.04%、13.78%、6.35%、0.41%(P<0.05)。图像引导后PTV外放边界估算得x、y、z轴向外放边界分别为1.87、1.75、1.69mm。结论 体表铅点标记辅助iSCOUT图像引导定位系统在乳腺癌放疗体位验证及校正中的应用具有可行性和应用价值,且为临床PTV外放边界提供新的参考。  相似文献   

19.
Objective To investigate whether adjuvant skin-marker positioning can decrease the set-up errors in overweight patients with thoracic and abdominal tumors. Methods A total of 60 overweight patients with thoracic and abdominal tumors treated with radiotherapy in the First Affiliated of Fujian Medical University between January 2018 and December 2018 were randomly divided into two groups. In group A, conventional skin-marker positioning was adopted. In group B, conventional skin-marker positioning combined with adjuvant skin-marker position was employed. All patients were immobilized with thermoplastic positioning body membrane with head-body plate fixation. The set-up errors in the right-left, head-foot and dorsoventral directions were obtained from cone-beam CT (CBCT) scan system before radiation delivery. The set-up errors were statistically compared between two groups by using t-test. Results In group A, the set-up errors in the right-left, head-foot and dorsoventral directions were (4.47±2.91) mm,(5.43±2.61) mm and (3.87±2.40) mm, significantly higher compared with (2.97±1.68) mm,(3.21±1.62) mm and (2.59±1.57) mm, respectively (all P<0.001). Conclusion Adjuvant skin-marker positioning method can reduce the set-up errors and enhance the positioning repeatability in overweight patients with thoracic and abdominal tumors receiving radiotherapy.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号