首页 | 本学科首页   官方微博 | 高级检索  
检索        

Norplant皮下埋植避孕剂与Vcu200宫内节育器5年临床对比观察
引用本文:孟凡,谢争,龚泉,吴明辉.Norplant皮下埋植避孕剂与Vcu200宫内节育器5年临床对比观察[J].首都医学院学报,2004,25(3):387-390.
作者姓名:孟凡  谢争  龚泉  吴明辉
作者单位:首都医科大学附属北京妇产医院 (孟凡,谢争,龚泉),首都医科大学附属北京妇产医院(吴明辉)
摘    要:为指导育龄妇女选用适宜的避孕方法 ,采用统一的接受标准 ,共接收Norplant使用者 3 1 5例 ,Vcu2 0 0使用者 3 2 0例 ,每 6个月随访 1次 ,直至 5年使用期满或终止使用。用生命表法统计 2组间各种事件率 ,使用WHO的MDS软件统计月经日记卡并分析出血类型 ,对 2组间的差异行统计学检验。结果显示 :Norplant使用者 5年持续使用率和因妊娠、月经问题、医学问题、避孕器反应的终止率分别为 80 .0 7%、0 .3 5 %、1 3 .3 7%、6.1 2 %和 0 .46% ;Vcu2 0 0组分别为 84.42 %、9.5 0 %、1 .71 %、0 .3 7%和 4.40 %。阴道出血类型分析显示 ,Norplant组不规则出血者占 43 .1 %~5 7.6% ,使用 6个月后阴道出血基本正常者占 1 2 .9%~ 3 2 .7% ;Vcu2 0 0组出血基本正常者可达 5 4.8%~ 60 .2 %。结果表明 :Norplant埋植剂和Vcu2 0 0节育器具有相同的持续使用率 ,使用Norplant埋植剂后的妊娠率和脱出率明显低于Vcu2 0 0节育器 ,而阴道出血类型中不规则出血明显高于Vcu2 0 0节育器。提示 :2种避孕方法各有优缺点

关 键 词:Norplant  宫内节育器  持续使用率  终止率
收稿时间:2003-08-27
修稿时间:2003年8月27日

Clinical Comparison of Norplant and Vcu200
Meng Fan,Xie Zheng,Gong Quan,Wu Minghui Beijing Obstetrics and Gynecology Hospital,Affiliate of Capital University of Medical Sciences.Clinical Comparison of Norplant and Vcu200[J].Journal of Capital University of Medical Sciences,2004,25(3):387-390.
Authors:Meng Fan  Xie Zheng  Gong Quan  Wu Minghui Beijing Obstetrics and Gynecology Hospital  Affiliate of Capital University of Medical Sciences
Institution:Beijing Obstetrics and Gynecology Hospital, Affiliate of Capital University of Medical Sciences
Abstract:The aim was to compare the effectiveness, the rates of side effects, discontinuation and menstrual bleeding patterns in Norplant and IUD.A randomized and clinical trial was done.The users of Norplant and Vcu200 were 315 and 320, respectively.The rates of continuation and discontinuation between two groups were compared by life table method and log-rank Chi-Square method.MDS recommended by WHO was used to analyze the menstrual bleeding patterns.Results: The cumulative continuation rate of Norplant and Vcu200 users were 80.07% and 84.42%, respectively.There was no statistic difference.The cumulative discontinuation of pregnancy, menstrual problem, other medical problem and contraceptive advice problem were 0.35%, 13.37%, 6.12%, 0.46% in Norplant users and 9.50%, 1.71%, 0.37%, 4.40% in Vcu200 users.The analysis of menstrual bleeding patterns showed the rate of irregular bleeding in Norplant users was 43.1%~57.6%.The rate of “normal patterns” was 12.9%~32.7% after six months using Norplant.The rate of “normal patterns” was 54.8%~60.2% in Vcu200 users.There was similar continuation rate between Norplant and Vcu200 for five years.In Norplant users the rate of pregnancy was lower, but the rate of irregular bleeding was higher.There are advantage and disadvantage between Norplant and Vcu200, respectively.
Keywords:Norplant  IUD  continuation rate  discontinuation rate
本文献已被 CNKI 维普 万方数据 等数据库收录!
点击此处可从《首都医学院学报》浏览原始摘要信息
点击此处可从《首都医学院学报》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号