首页 | 本学科首页   官方微博 | 高级检索  
文章检索
  按 检索   检索词:      
出版年份:   被引次数:   他引次数: 提示:输入*表示无穷大
  收费全文   77篇
  免费   10篇
妇产科学   7篇
基础医学   12篇
口腔科学   2篇
临床医学   5篇
内科学   14篇
皮肤病学   17篇
神经病学   6篇
特种医学   2篇
外科学   6篇
综合类   4篇
预防医学   3篇
眼科学   6篇
药学   2篇
肿瘤学   1篇
  2023年   2篇
  2022年   1篇
  2021年   4篇
  2020年   8篇
  2019年   10篇
  2018年   8篇
  2017年   4篇
  2016年   5篇
  2015年   3篇
  2014年   2篇
  2013年   3篇
  2012年   10篇
  2011年   7篇
  2010年   3篇
  2009年   2篇
  2008年   5篇
  2007年   4篇
  2006年   3篇
  2005年   1篇
  2003年   1篇
  2001年   1篇
排序方式: 共有87条查询结果,搜索用时 140 毫秒
1.
The gold standard treatment for anterior cruciate ligament (ACL) reconstruction is the use of tendon autografts and allografts. Limiting factors for this treatment include donor site morbidity, potential disease transmission, and variable graft quality. To address these limitations, we previously developed an off-the-shelf alternative, a poly(l-lactic) acid (PLLA) bioengineered ACL matrix, and demonstrated its feasibility to regenerate ACL tissue. This study aims to 1) accelerate the rate of regeneration using the bioengineered ACL matrix by supplementation with bone marrow aspirate concentrate (BMAC) and growth factors (BMP-2, FGF-2, and FGF-8) and 2) increase matrix strength retention. Histological evaluation showed robust tissue regeneration in all groups. The presence of cuboidal cells reminiscent of ACL fibroblasts and chondrocytes surrounded by an extracellular matrix rich in anionic macromolecules was up-regulated in the BMAC group. This was not observed in previous studies and is indicative of enhanced regeneration. Additionally, intraarticular treatment with FGF-2 and FGF-8 was found to suppress joint inflammation. To increase matrix strength retention, we incorporated nondegradable fibers, polyethylene terephthalate (PET), into the PLLA bioengineered ACL matrix to fabricate a “tiger graft.” The tiger graft demonstrated the greatest peak loads among the experimental groups and the highest to date in a rabbit model. Moreover, the tiger graft showed superior osteointegration, making it an ideal bioengineered ACL matrix. The results of this study illustrate the beneficial effect bioactive factors and PET incorporation have on ACL regeneration and signal a promising step toward the clinical translation of a functional bioengineered ACL matrix.

The goal of developing a bioengineered anterior cruciate ligament (ACL) matrix is to provide an off-the-shelf product that is functionally superior to autografts and allografts currently used for ACL reconstruction surgeries. There is clear need for advancement in this area as 30% of young active patients reinjure their ACL after surgery (1). Furthermore, athletes in the National Basketball Association and National Football League have a return-to-sport time after ACL reconstruction of 11.6 and 10.8 mo, respectively (2, 3). This lengthy period of rehabilitation has spurred interest in bioengineered ACL matrices that can accelerate and enhance ACL regeneration, so that all patients can return to their preinjury performance level faster.Our group previously fabricated a poly(l-lactic) acid (PLLA) bioengineered ACL matrix and evaluated its performance in rabbit ACL reconstruction models (47). The bioengineered ACL matrix resulted in excellent tissue regeneration, while experiencing a 41 to 66% rupture rate in vivo (4, 5). The cause of these ruptures was likely due to the interplay between the rate of tissue regeneration and matrix fatigue. Thus, this study aims to 1) accelerate ACL regeneration by supplementing the bioengineered ACL matrix with bone marrow aspirate concentrate (BMAC) and growth factors (bone morphogenetic protein 2 [BMP-2], fibroblast growth factor 2 [FGF-2], and FGF-8); and 2) increase the strength retention of the bioengineered ACL matrix by incorporating nondegradable polyethylene terephthalate (PET) yarns.BMAC is a promising translational stem cell therapy as it can be harvested and applied during surgery and is not regulated by the US Food and Drug Administration (FDA) (8, 9). The ability of BMAC to enhance the repair of damaged rotator cuff (10) and meniscus (11) tissues has been demonstrated in rabbit models. Thus, we hypothesized that the application of BMAC would serve as a source of progenitor cells and bioactive factors that would accelerate ACL regeneration. This report evaluates the feasibility of obtaining BMAC in a rabbit ACL reconstruction model and its regenerative potential.Growth factors have been widely investigated to accelerate bone and ligament regeneration through the proliferation and differentiation of progenitor cells (12). FGFs have been shown to stimulate the proliferation of cells and enhance tissue healing. In particular, FGF-2 has been shown to accelerate ligament healing (13), and a member of the FGF-8 subfamily has been shown to stimulate cartilage healing in a clinical study (14). Furthermore, the synergistic application of FGF-2 and FGF-8 induced dedifferentiation of mature cells in axolotls (15). Given the evidence supporting the proregenerative qualities of FGF-2 and FGF-8, we chose to apply FGF-2 and FGF-8 simultaneously in the intraarticular space. We hypothesized that the combinatorial application of FGF-2 and FGF-8 would accelerate ligamentization of the bioengineered ACL matrix by promoting the proliferation of progenitor cells and dedifferentiation of mature cells in the synovial environment.To accelerate bone regeneration, we utilized bone morphogenetic protein 2 (BMP-2), which is approved by the US FDA for a range of lumbar spinal fusion procedures and has been shown in ACL reconstruction models to enhance osteointegration of tendon grafts (1618). In our previous study, we demonstrated that BMP-2 saline injections could enhance osteoid seam width and reduce bone tunnel cross-sectional area, a sign of bone regeneration (5). However, the effect was limited, likely due to the lack of a drug carrier. In this study, we hypothesized that the addition of a drug delivery carrier, fibrin glue (1922), would potentiate the effect of BMP-2 and promote bone formation (23).The first iteration of the bioengineered ACL matrix, termed the “L-C ligament,” was completely biodegradable and composed of only PLLA yarns (4). The high rupture rate found in our previous study motivated us to modify the material composition of the bioengineered ACL matrix to reduce its mechanical fatigue rate. A compelling polymer to reduce fatigue rate is PET, a biocompatible nondegradable polymer with high tensile strength that has previously been utilized for orthopedic applications (24). To date, no study has investigated the use of a composite PLLA and PET bioengineered ACL matrix for ACL reconstruction. Following the patented design by Laurencin and colleagues (25), a composite bioengineered ACL matrix, termed the “tiger graft,” composed of 20 PLLA yarns and 4 PET yarns, was fabricated. The PLLA facilitates a greater volume of tissue regeneration as it gradually degrades, while the PET bolsters the mechanical strength of the matrix during the early phases of healing. We hypothesized that the tiger graft would have increased mechanical strength retention over the implantation period.The overall goal of this study was to accelerate ACL regeneration of a bioengineered ACL matrix by supplementation with BMAC and growth factors (BMP-2, FGF-2, and FGF-8) and by modulating the material composition of the matrix (Fig. 1). We evaluated the ligamentization and osteointegration of the bioengineered ACL matrices histologically. Microcomputed tomography (µCT) was performed to evaluate bone tunnel regeneration. The inflammatory and remodeling state of the synovial fluid was evaluated using an enzyme-linked immunosorbent assay (ELISA). Finally, biomechanical testing was conducted to determine the strength retention of the bioengineered ACL matrices.Open in a separate windowFig. 1.Fabrication of the bioengineered ACL matrix and implantation in a rabbit ACL reconstruction model. (A) Depiction of the braiding machine used to fabricate the bioengineered ACL matrices and the resulting biphasic structure of the matrix. Each matrix was composed of 24 yarns. (B) For the L-C ligament, 24 yarns of PLLA were braided together. For the tiger graft, 20 yarns of PLLA and 4 yarns of PET were braided together. Experimental groups were evaluated at 12 wk, and the L-C ligament (control) was further evaluated at 24 wk. (C) View of implanted bioengineered ACL matrix at the time of surgery (Left) and the application of fibrin glue (Right). BMAC or growth factors were mixed with fibrin glue for the experimental groups. (D) Representative image demonstrating the implantation of a fibrin gel in the tibial bone tunnel (Left, blue arrow) and subsequent fixation of a titanium suture button (Right).  相似文献   
2.
AIM: To assess lens thickness measurements with anterior segment-optical coherence tomography (AS-OCT) in comparison with A-scan ultrasonography (A-scan US). METHODS: There were 218 adult subjects (218 eyes) aged 59.2±9.2y enrolled in this prospective cross-sectional study. Forty-three eyes had open angles and 175 eyes had narrow angles. Routine ophthalmic exam was performed and nuclear opacity was graded using the Lens Opacities Classification System III (LOCS III). Lens thickness was measured by AS-OCT (Visante OCT, Carl Zeiss Meditec, Dublin, CA, USA). The highest quality image was selected for each eye and lens thickness was calculated using ImageJ software. Lens thickness was also measured by A-scan US. RESULTS: Interclass correlations showed a value of 99.7% for intra-visit measurements and 95.3% for inter-visit measurements. The mean lens thickness measured by AS-OCT was not significantly different from that of A-scan US (4.861±0.404 vs 4.866±0.351 mm, P=0.74). Lens thickness values obtained from the two instruments were highly correlated overall (Pearson correlation coefficient=0.81, P<0.001), and in all LOCS III specific subgroups except in grade 5 of nuclear opacity. Bland-Altman analysis revealed a 95% limit of agreement from -0.45 to 0.46 mm. Lens thickness difference between the two instruments became smaller as the lens thickness increased and AS-OCT yielded smaller values than A-scan US in thicker lens (β=-0.29, P<0.001) CONCLUSION: AS-OCT-derived lens thickness measurement is valid and comparable to the results obtained by A-scan US. It can be used as a reliable noncontact method for measuring lens thickness in adults with or without significant cataract.  相似文献   
3.
Autozygosity mapping (AM) is a technique utilised for mapping homozygous autosomal recessive (AR) traits and facilitation of genetic diagnosis. We investigated the utility of AM for the molecular diagnosis of heterogeneous AR disorders, using epidermolysis bullosa (EB) as a paradigm. We applied this technique to a cohort of 46 distinct EB families using both short tandem repeat (STR) and genome‐wide single nucleotide polymorphism (SNP) array‐based AM to guide targeted Sanger sequencing of EB candidate genes. Initially, 39 of the 46 cases were diagnosed with homozygous mutations using this method. Independently, 26 cases, including the seven initially unresolved cases, were analysed with an EB‐targeted next‐generation sequencing (NGS) panel. NGS identified mutations in five additional cases, initially undiagnosed due to the presence of compound heterozygosity, deep intronic mutations or runs of homozygosity below the set threshold of 2 Mb, for a total yield of 44 of 46 cases (95.7%) diagnosed genetically.  相似文献   
4.
International Journal of Mental Health and Addiction - Substance use and psychiatric disorders are highly prevalent in persons experiencing homelessness. We aimed to investigate the associations...  相似文献   
5.
Background: Respiratory distress syndrome (RDS) is a severe pulmonary disease predominantly affects preterm newborns. Polymorphisms of surfactant-protein genes have been mostly evaluated as the candidate contributors in genetics of RDS. However the results are divers in different studies. We aimed at investigating the association of surfactant protein B (SPB) gene 9306 A/G polymorphism (rs7316) with RDS development.

Method: Three hundred and eighty newborns with gestational age of less than 34 weeks were included in a multicenter case–control study. Respiratory distress (RD) was scored according to Downes’ scoring system. Polymerase chain reaction–restriction fragment length polymorphism (PCR-RFLP) method was used for genotyping.

Result: One hundred and eighty-four neonates showed RDS and 196 did not. Gestational age (GA) was significantly lower in the RDS group compared with the controls. AA genotype and A allele were found more frequently in the RDS group than the controls (96.2% versus 63.8% and 98.1% versus 80.6%, respectively) (p =.0001).

Conclusions: This is the first report of association of SFTPB rs7316 polymorphism with RDS development in Iranian newborns. The current study suggests that GA <28-weeks is the most important factor in predisposition to RDS. Genetic background in terms of SP-B gene might be involved in predisposition to RDS in premature neonates.  相似文献   

6.
7.
AIM: Venous obstruction following transvenous device implantation rarely cause immediate clinical problems. When lead revision or device upgrade is indicated, venous obstruction become a significant challenge. The aim of this study was to determine the predictors of venous obstruction after transvenous device implantation, and to asess likely effects of antiplatelet/anticoagulant drugs in preventing venous thrombosis. METHODS AND RESULTS: Between March 2005 and July 2006, contrast venography was performed in 100 patients who were candidates for generator change, lead revision, or device upgrade. Vessel patency was graded as either completely obstructed, partially obstructed (>70%), or patent. The incidence of venous obstruction was 26%, with 9% of patients having total obstruction and 17% of patients exhibiting partial obstruction. No statistically significant differences between obstructed and non-obstructed patients were seen for age, sex, indication for device implantation, atrial fibrillation, cardiothoracic ratio, insulation material, operative technique, device type, and manufacturer (all Ps > 0.05). In a univariate analysis, multiple leads (P = 0.033), and presence of dilated cardiomyopathy (P = 0.036) were associated with higher risk of venous obstruction, whereas anticoagulant/antiplatelet therapy (P = 0.047) significantly reduced incidence of venous obstruction. Multivariate logistic regression analysis showed that only number of the leads (P = 0.039, OR: 2.22, and 95% CI: 1.03-4.76) and antiplatelet/anticoagulant therapy (P = 0.044, OR: 2.79, and 95% CI: 0.98-7.96) were predictors of venous obstruction. CONCLUSION: Total or partial obstruction of the access veins occurs relatively frequently after pacemaker or ICD implantation. Multiple pacing or ICD leads are associated with an increased risk of venous obstruction, whereas antiplatelet/anticoagulant therapy appears to have a preventive effect on development of access vein thrombosis.  相似文献   
8.
Metastases to the skin from carcinoma arising in other organs are uncommon, yet they may be the first presentation of neoplastic disease. They usually originate from primary tumours in the breast, lung or colon. Skin metastases from esophageal adenocarcinoma are extremely rare. A unique case of an otherwise healthy patient who presented with a small, painless, mobile, clinically localized facial skin nodule is reported. A biopsy revealed metastatic adenocarcinoma, and subsequent investigations detected the primary tumour in the esophagus, despite no symptoms.  相似文献   
9.
10.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号