Isotactic polypropylenes (iPP) with different melt flow indexes (MFI) were used to fabricate nanocomposites (NCs) with 10 wt % loadings of multi-wall carbon nanotubes (MWCNTs) using ultrasound-assisted extrusion methods to determine their effect on the morphology, melt flow, and electrical properties of the NCs. Three different types of iPPs were used with MFIs of 2.5, 34 and 1200 g/10 min. Four different NC fabrication methods based on melt extrusion were used. In the first method melt extrusion fabrication without ultrasound assistance was used. In the second and third methods, an ultrasound probe attached to a hot chamber located at the exit of the die was used to subject the sample to fixed frequency and variable frequency, respectively. The fourth method is similar to the first method, with the difference being that the carbon nanotubes were treated in a fluidized air-bed with an ultrasound probe before being used in the fabrication of the NCs with no ultrasound assistance during extrusion. The samples were characterized by MFI, Optical microscopy (OM), Scanning electron microscopy (SEM), Transmission electron microscopy (TEM), electrical surface resistivity, and electric charge. MFI decreases in all cases with addition of MWCNTs with the largest decrease observed for samples with the highest MFI. The surface resistivity, which ranged from 1013 to 105 Ω/sq, and electric charge, were observed to depend on the ultrasound-assisted fabrication method as well as on the melt flow index of the iPP. A relationship between agglomerate size and area ratio with electric charge was found. Several trends in the overall data were identified and are discussed in terms of MFI and the different fabrication methods. 相似文献
AIM: To evaluate in a prospective multicenter study the efficacy and safety of the suburethral support Uretex (Sofradim, Trevoux, France) delivered by a suprapubic approach in the treatment of female stress urinary incontinence. METHODS: Between March 2002 and March 2003, 57 patients were treated for stress urinary incontinence with Uretex. Preoperative evaluation included urodynamic examination and questionnaires (symptoms and quality of life, Contilife). Forty patients had pure stress urinary incontinence and 17 mixed urinary incontinence. No associated procedure was performed. The objective cure rate was evaluated by clinical examination and pad-test, and the subjective cure rate was assessed through questionnaires at 1, 3 and 12 months. RESULTS: The mean follow-up was 13 months (range 11-24 months). During follow up, chronic urinary retention requiring a tape section occurred in one patient, and in another patient a delay of vaginal healing was followed by a sling exposure and resection at 4 months. No infection or urethral erosion was reported. The objective cure rate was 96.2%, and the subjective cure rate was 79.2%; four patients reported low leakage on stress and nine patients complained of urge incontinence (four de novo and five persistent). CONCLUSION: The suprapubic Uretex Sup procedure is a safe and effective treatment for women with stress urinary incontinence. 相似文献
Belli , A. & Bosco, A. 1992. Influence of stretch-shortening cycle on mechanical behaviour of triceps surae during hopping. Acta Physiol Scand 144 , 401408. Received 20 March 1 991 , accepted 3 December 1991. ISSN 0001–6772. Laboratories of Physiology, Universities of St Etienne and Lyon, France and Departments of Biology and Physical Activity, University of Jyväskylä, Finland. Six subjects performed a first series of vertical plantar flexions and a second series of vertical rebounds, both involving muscle triceps surae exclusively. Vertical displacements, vertical forces and ankle angles were recorded during the entire work period of 60 seconds per series. In addition, expired gases were collected during the test and recovery for determination of the energy expenditure. Triceps surae was mechanically modelled with a contractile component and with an elastic component. Mechanical behaviour and work of the different muscle components were determined in both series. The net muscular efficiency calculated from the work performed by the centre of gravity was 17.5±3.0% (mean ± SD) in plantar flexions and 29.9 ± 4.8% in vertical rebounds. The net muscle efficiency calculated from the work performed by the contractile component was 17.4 %% 2.9% in plantar flexions and 16.1 ± 1.47; in vertical rebounds. These results suggest that the muscular efficiency differences do not reflect muscle contractile component efficiency but essentially the storage and recoil of elastic energy. This is supported by the relationship (P < 0.01) found in vertical rebounds between the extra work and the elastic component work. A detailed observation of the mechanical behaviour of muscle mechanical components showed that the strategy to maximize the elastic work depends also on the force-velocity characteristics of the movement and that the eccentric-concentric work of the contractile component does not always correspond respectively to the ankle extension-flexion. 相似文献
Background. A membrane oxygenator consisting of a microporous polypropylene hollow fiber with a 0.2-μm ultrathin silicone layer (cyclosiloxane) was developed. Animal experimental and preliminary clinical studies evaluated its reliability in bypass procedures.
Methods. Five 24-hour venoarterial bypass periods were conducted on dogs using the oxygenator (group A). In 5 controls, bypass periods were conducted using the same oxygenator without silicone coating (group B). As a preliminary clinical study, 14 patients underwent cardiopulmonary bypass with the silicone-coated oxygenator.
Results. Eight to 16 hours (mean, 12.2 hours) after initiation of bypass, plasma leakage occurred in all group B animals, but none in group A. The O2 and CO2 transfer rates after 24 hours in group A were significantly higher than at termination of bypass in group B (p < 0.005 and p < 0.03, respectively). Scanning electron microscopy of silicone-coated fibers after 24 hours of bypass revealed no damage to the silicone coating of the polypropylene hollow fibers. In the clinical study, the oxygenator showed good gas transfer, acceptable pressure loss, low hemolysis, and good durability.
Conclusions. This oxygenator is more durable and offers greater gas transfer capabilities than the previous generation of oxygenators. 相似文献
The aim of the study was to investigate if the stretch reflex of the soleus muscle was useful in quantifying upper motor neuron lesions. The soleus stretch reflex was recorded in 10 healthy subjects and 20 patients with active relapsing-remitting multiple sclerosis and correlated to the number of MRI lesions in cerebrum and clinical scores (expanded disability status scale and regional functional scoring system). The short latency stretch reflex was elicited by rotating the left ankle joint 4 degrees with a rise time in the interval of 40-640 ms. The amplitude of the stretch was larger in multiple sclerosis patients being 88.5 microV in patients and 12.8 microV in controls, P = 0.007. The sensitivity of the stretch reflex expressed as the slope of the best linear fit was increased in MS patients to 2.6 microVs/degree compared with 0.6 microVs/degree (0.1-2.2) in controls, P = 0.009. There was no correlation between amplitude of the stretch reflex and number of MRI lesions (r = -0.03). In conclusion, the soleus stretch reflex might be useful to quantify spasticity but is not useful in detecting dysfunction of upper motor neurons in MS. 相似文献
During apneic periods elicited by high-frequency oscillatory ventilation (HFOV) a tonic diaphragmatic activity was observed, contrasting with the absence of diaphragmatic activity during apnea induced by lung inflation. To clarify the mechanism underlying the persistence of the diaphragmatic activity during HFOV-induced arrest of breathing the reflex responses to short periods of HFOV, and to periods of lung inflation with airway pressure (Paw) equal to the meanPaw and/or to maximalPaw during HFOV were examined both before and after the blockade of slowly adapting stretch receptors (SR) by inhalation of sulphur dioxide (SO2) in anaesthetized rabbits. In animals with intact SR, the HFOV-induced reflex apnea lasted longer than that induced by lung inflation, the associated diaphragmatic activity being in the most cases higher than the diaphragmatic activity during quiet expiration; inflation, however, completely inhibited diaphragmatic activity. After blockade of SR, spontaneous breathing continued during periods of lung inflation, i.e., the Hering-Breuer inflation reflex was abolished, whereas HFOV still led to a cessation of spontaneous breathing, the associated diaphragmatic activity even exceeding the level observed during quiet inspiration. From these results we conclude that only one part of the reflex response to HFOV is due to SR-stimulation and that in addition other vagal pulmonary receptors (irritant-and/or C-fibre-receptors) are involved. The stimulation of the latter counterbalances the concomitant stimulation of SR, giving rise to the tonic activity of the diaphragm. 相似文献
Summary The cat gastrocnemius muscles of one hind leg were stretched sinusoidally with amplitudes between 10 m and 2.5 mm and frequencies between 1 and 30 Hz. The stretch response of deefferented muscle spindle afferents and of Ia-activated cells within Clarke's column were investigated by means of extra-cellular recordings of action potentials. The responses to 20–50 cycles were displayed in impulse patterns (raster diagrams) of the responding action potentials. The impulse patterns of Ia afferents exhibited a high degree of phase-locking (regularity) on the stretch cycle of amplitudes of about 50 m at 3 Hz and all higher amplitudes or frequencies. At comparable stretch parameters the regularity in Ia afferents was 4–6 times larger than in Ia-activated DSCT neurons. The regularity in the DSCT patterns increased with an increase in stretch frequency. The impulse patterns of DSCT cells exhibited a high negative correlation between successive interspike intervals (–0.4 to –0.6) at low stretch frequencies (<3 Hz), which decreased with an increase in stretch frequency. 相似文献