Introduction: Percutaneous renal mass biopsy has evolved over the last decade with improvements on previous pitfalls including low tissue yield, high non-diagnostic rates, and complications. As understanding of tumor biology and natural history of renal cortical neoplasms has improved, percutaneous renal mass biopsy is poised to have an expanding role in an area characterized by individualized management and refined risk stratification.
Areas covered: This review summarizes the evolution of renal mass biopsy to its current state with respect to outcomes, indications, and clinical guidelines.
Expert opinion: With improved understanding of differential biological potential of renal cortical neoplasms combined with technical improvements in diagnostic yield and accuracy, utilization of renal mass biopsy is becoming an important adjunct to patient care in a broad range of clinical scenarios, including active surveillance, thermal ablation, and use of primary systemic therapy in localized and advanced settings. 相似文献
Particle size analysis in the pharmaceutical industry has long been a source of debate regarding how best to define measurement accuracy; the degree to which the result of a measurement or calculation conforms to the true value. Defining a “true” value for the size of a particle can be challenging as the output of its measurement will differ because of variations in measurement approaches, instrumental differences and calculation methods. Consequently, for “real” particles, a universal “true” value does not exist and accuracy is therefore not a definable characteristic. Accordingly, precision is then a measure of the ability to reproducibly achieve a measurement of unknown relevance.This article proposes, in place of accuracy, a means to define the “appropriateness” of a measurement in line with the critical quality attributes (CQA) of the material being characterized. The decision as to whether the measurement is correct should involve a link to the CQA; that is, correlation should be demonstrated, without which the measured particle size cannot be defined as a critical material attribute.Correspondingly, methods should also be able to provide sufficient precision to demonstrate discrimination relating to variation in the CQA. The benefits and challenges of this approach are discussed. 相似文献
IntroductionPredicting pathological complete response (pCR) for patients receiving neoadjuvant chemotherapy (NAC) is crucial in establishing individualized treatment. Whole-slide images (WSIs) of tumor tissues reflect the histopathologic information of the tumor, which is important for therapeutic response effectiveness. In this study, we aimed to investigate whether predictive information for pCR could be detected from WSIs.Materials and methodsWe retrospectively collected data from four cohorts of 874 patients diagnosed with biopsy-proven breast cancer. A deep learning pathological model (DLPM) was constructed to predict pCR using biopsy WSIs in the primary cohort, and it was then validated in three external cohorts. The DLPM could generate a deep learning pathological score (DLPs) for each patient; stromal tumor-infiltrating lymphocytes (TILs) were selected for comparison with DLPs.ResultsThe WSI feature-based DLPM showed good predictive performance with the highest area under the curve (AUC) of 0.72 among the cohorts. Alternatively, the combination of the DLPM and clinical characteristics offered a better prediction performance (AUC >0.70) in all cohorts. We also evaluated the performance of DLPM in three different breast subtypes with the best prediction for the triple-negative breast cancer (TNBC) subtype (AUC: 0.73). Moreover, DLPM combined with clinical characteristics and stromal TILs achieved the highest AUC in the primary cohort (AUC: 0.82) and validation cohort 1 (AUC: 0.80).ConclusionOur study suggested that WSIs integrated with deep learning could potentially predict pCR to NAC in breast cancer. The predictive performance will be improved by combining clinical characteristics. DLPs from DLPM can provide more information compared to stromal TILs for pCR prediction. 相似文献
ObjectiveWe aimed to establish an objective neurophysiological test protocol that can be used to assess the somatosensory nervous system.MethodsIn order to assess most fiber subtypes of the somatosensory nervous system, repetitive stimuli of seven different modalities (touch, vibration, pinprick, cold, contact heat, laser, and warmth) were synchronized with the electroencephalogram (EEG) and applied on the cheek and dorsum of the hand and dorsum of the foot in 21 healthy subjects and three polyneuropathy (PNP) patients. Latencies and amplitudes of the modalities were assessed and compared. Patients received quantitative sensory testing (QST) as reference.ResultsWe found reproducible evoked potentials recordings for touch, vibration, pinprick, contact-heat, and laser stimuli. The recording of warm-evoked potentials was challenging in young healthy subjects and not applicable in patients. Latencies were shortest within Aβ-fiber-mediated signals and longest within C-fibers. The test protocol detected function loss within the Aβ-fiber and Aδ-fiber-range in PNP patients. This function loss corresponded with QST findings.ConclusionIn this pilot study, we developed a neurophysiological test protocol that can specifically assess most of the somatosensory modalities. Despite technical challenges, initial patient data appear promising regarding a possible future clinical application.SignificanceEstablished and custom-made stimulators were combined to assess different fiber subtypes of the somatosensory nervous system using modality-specific evoked potentials. 相似文献
Purpose: To study, with computational models, the utility of power modulation to reduce tissue temperature heterogeneity for variable nanoparticle distributions in magnetic nanoparticle hyperthermia.
Methods: Tumour and surrounding tissue were modeled by elliptical two- and three-dimensional computational phantoms having six different nanoparticle distributions. Nanoparticles were modeled as point heat sources having amplitude-dependent loss power. The total number of nanoparticles was fixed, and their spatial distribution and heat output were varied. Heat transfer was computed by solving the Pennes’ bioheat equation using finite element methods (FEM) with temperature-dependent blood perfusion. Local temperature was regulated using a proportional-integral-derivative (PID) controller. Tissue temperature, thermal dose and tissue damage were calculated. The required minimum thermal dose delivered to the tumor was kept constant, and heating power was adjusted for comparison of both the heating methods.
Results: Modulated power heating produced lower and more homogeneous temperature distributions than did constant power heating for all studied nanoparticle distributions. For a concentrated nanoparticle distribution, located off-center within the tumor, the maximum temperatures inside the tumor were 16% lower for modulated power heating when compared to constant power heating. This resulted in less damage to surrounding normal tissue. Modulated power heating reached target thermal doses up to nine-fold more rapidly when compared to constant power heating.
Conclusions: Controlling the temperature at the tumor-healthy tissue boundary by modulating the heating power of magnetic nanoparticles demonstrably compensates for a variable nanoparticle distribution to deliver effective treatment. 相似文献
PurposeAttempts by magnetic resonance (MR) manufacturers to help imaging centres improve patient throughput has led to the development of more automated acquisition. This software is capable of customizing individual scan alignment; potentially improving imaging efficiency and standardizing protocols. However, substantial investments are required to introduce such systems, potentially deterring their widespread application. This study assessed the implementation costs and reduction in examination durations for automated knee MR imaging (MRI) software.Materials and MethodsResearch activities were performed at a community-based academic centre on a 3-Tesla (3-T) system using Siemens' Day Optimizing Throughput (Dot) knee software. Examination acquisition times were extracted from the system before and after software implementation. Fiscal year 2012/13 finances were used to determine the average hourly cost of MRI utilization. Costs associated with automated software implementation were also calculated. Finally, the number of knee scans required to achieve a positive return on investment using the software was established.Results and DiscussionThe mean (standard deviation, sample size) pre- and post-Dot software scan times were 23.20 (4.18, n = 266) and 21.94 (4.51, n = 59) minutes, respectively, for a routine knee scan and 11.88 (1.60, n = 74) and 11.24 (1.51, n = 27) minutes, respectively, for a fast knee scan. The overall weighted average resulted in a 64-second time savings per automated knee examination. This negligible time savings would be extremely difficult to make use of clinically. Dot simplified 29 unique knee protocols to two, improving the consistency of knee examinations. Current Dot software is not compatible with all patients and therefore has limitations that are a concern among MR technologists.ConclusionAdoption of automated knee systems could assist in standardizing protocols; however, the cost of implementation and difficulty in modifying patient scheduling to reflect the minimal time savings would make a financial return unlikely to occur at small- and medium-sized institutions. 相似文献
IntroductionThis study aims to construct learning curves related to the realization of standardized postprocessing by radiographer students and to discuss their exploitation and interest.Materials and MethodsThis study was carried out in 21 French students in their 3rd year of training. Two postprocessing protocols in CT (#1 traumatic shoulder; #2 petrous bone) were repeated 15 times by each student. Each achievement was timed to obtain overall learning curves. The realization accuracy was also assessed for each student at each repetition.ResultsThe learning rates for the two protocols are 63% and 56%, respectively. The number of repetitions to reach the reference time for each protocol is 11 and 12, respectively. In both protocols, the standard deviations are significantly reduced and stabilized during repetitions. The mean accuracy progresses more quickly in protocol #1.DiscussionThe measured learning rates reflect a rapid learning process for each protocol. The analysis of the standard deviations shows that students have reached a homogeneous level. The average times and accuracies measured during the last repetitions show that the group has reached a high level of performance. Building learning curves helps students measure their progress and motivates them.ConclusionObtaining learning curves allows trainers/supervisors to qualify the learning difficulty of a task while motivating students/radiographers. The use of learning curves is inline with the competency-based training paradigm. 相似文献
IntroductionThis study evaluated free water loss–induced residual strain with and without axial compressive loading and assessed the mechanical effect of cyclic loading in fully hydrated and partially dehydrated root dentin.MethodsRoot dentin sections prepared from freshly extracted human premolars were used. Customized 3-dimensional digital image correlation was used to qualitatively and quantitatively analyze the residual strain induced by 2 hours of free water loss in different regions of root dentin. Residual strain in partially dehydrated root dentin during axial compressive loading was also analyzed using 3-dimensional digital image correlation. The effect of cyclic loading on load to fracture in fully hydrated and partially dehydrated dentin and their fractography were analyzed using micro–computed tomographic imaging.ResultsFree water loss resulted in a heterogeneous distribution of residual strain and an overall formation of residual compressive strain with areas of tensile strain localized to the root canal and outer dentin. More residual compressive strain was observed in the apical dentin compared with the cervical dentin (P < .05), and more residual shear strain was observed in outer dentin compared with inner dentin (P < .05). Axial loading resulted in an increase in the load-induced compressive strain in the direction perpendicular to dentinal tubules (P < .05). Fully hydrated roots displayed a higher mean (P < .05) and median (P < .05) number of cycles to fracture with microcracks characteristic of toughness.ConclusionsAfter free water loss, root dentin displayed an increased formation of heterogenous residual strain, which resulted in increased axial compressive load-induced strain and a decreased resistance to fatigue failure. The effect of free water loss in the loss of mechanical integrity of root-filled teeth needs further investigation. 相似文献