首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.

Purpose

To evaluate changes in anterior chamber depth (ACD) and angle width induced by phacoemulsification and intraocular lens (IOL) implantation in eyes with glaucoma, using anterior segment optical coherence tomography (AS-OCT).

Methods

Eleven eyes of 11 patients with angle-closure glaucoma (ACG) and 12 eyes of 12 patients with open-angle glaucoma (OAG) underwent phacoemulsification and IOL implantation. Using AS-OCT, ACD and angle parameters were measured before and 2 days after surgery. Change in intraocular pressure (IOP) and number of ocular hypotensive drugs were evaluated.

Results

After surgery, central ACD and angle parameters increased significantly in eyes with glaucoma (p < 0.05). Prior to surgery, mean central ACD in the ACG group was approximately 1.0 mm smaller than that in the OAG group (p < 0.001). Post surgery, mean ACD of the ACG group was still significantly smaller than that of the OAG group. No significant differences were found in angle parameters between the ACG and OAG groups. In the ACG group, postoperative IOP at the final visit was significantly lower than preoperative IOP (p = 0.018) and there was no significant change in the number of ocular hypotensive medications used, although clinically, patients required fewer medications. In the OAG group, the IOP and number of ocular hypotensive drugs were almost unchanged after surgery.

Conclusions

The ACD and angle width in eyes with glaucoma increased significantly after phacoemulsification and IOL implantation. Postoperative ACD significantly differed between the ACG and OAG groups, whereas angle parameters did not differ.  相似文献   

2.

Purpose

Given the Veterans Affairs Boston Healthcare System''s recent introduction of single-use Tonosafe disposable tonometer prisms as an alternative to Goldmann applanation tonometers (GATs), this study had two aims: to conduct a large-scale quality assurance trial to assess the reliability of intraocular pressure (IOP) measurements of the Tonosafe disposable tonometer compared with GAT, particularly at extremes of pressure; to evaluate the suitability of Tonosafe disposable tonometer prisms as an acceptable substitute for GATs and for clinic-wide implementation in an academic tertiary referral setting.

Methods

Ophthalmology resident physicians measured the IOPs of patients in general and specialty eye clinics with the Tonosafe disposable tonometer and GAT. Tonosafe test–retest reliability data were also collected. A retrospective review of patient charts and data analysis were performed to determine the reliability of measurements.

Results

The IOPs of 652 eyes (326 patients) were measured with both GAT and Tonosafe, with a range of 3–34 mm Hg. Linear regression analysis showed R=0.93, slope=0.91, both of which supported the proposed hypothesis, and the y-intercept=−1.05 was significantly different from the hypothesized value. The Tonosafe test–retest repeatability (40 eyes of 40 patients), r=0.977, was very high, which was further supported by linear regression slope=0.993, y-intercept=0.118, and a Tonosafe repeatability coefficient of 2.06, similar to GAT repeatability.

Conclusions

The IOP measurements by Tonosafe disposable prisms correlated closely with Goldmann measurements, with similar repeated measurement variability to GAT. This suggests that the Tonosafe is an acceptable substitute for GAT to measure IOP in ophthalmology clinic settings.  相似文献   

3.

Objective:

To study the correlation and effect of sequential measurement of intraocular pressure (IOP) with Goldmann applanation tonometer (GAT), ocular response analyzer (ORA), dynamic contour tonometer (DCT), and Corvis ST.

Setting and Design:

Observational cross-sectional series from the comprehensive clinic of a tertiary eye care center seen during December 2012.

Methods:

One hundred and twenty-five study eyes of 125 patients with normal IOP and biomechanical properties underwent IOP measurement on GAT, DCT, ORA, and Corvis ST; in four different sequences. Patients with high refractive errors, recent surgeries, glaucoma, and corneal disorders were excluded so as to rule out patients with evident altered corneal biomechanics.

Statistical Analysis:

Linear regression and Bland–Altman using MedCalc software.

Results:

Multivariate analysis of variance with repeated measures showed no influence of sequence of device use on IOP (P = 0.85). Linear regression r2 between GAT and Corvis ST, Corvis ST and Goldmann-correlated IOP (IOPg), and DCT and Corvis ST were 0.37 (P = 0.675), 0.63 (P = 0.607), and 0.19 (P = 0.708), respectively. The Bland–Altman agreement of Corvis ST with GAT, corneal compensated IOP, and IOPg was 2 mmHg (−5.0 to + 10.3), −0.5 mmHg (−8.1 to 7.1), and 0.5 mmHg (−6.2 to 7.1), respectively. Intraclass correlation coefficient for repeatability ranged from 0.81 to 0.96.

Conclusions:

Correlation between Corvis ST and ORA was found to be good and not so with GAT. However, agreement between the devices was statistically insignificant, and no influence of sequence was observed.  相似文献   

4.

Purpose

To compare the intraocular pressures (IOPs) obtained with the IOPen rebound tonometer, Goldmann applanation tonometer (GAT) and the ocular response analyzer (ORA) and investigate the effects of corneal biomechanical properties on IOPen measurements.

Methods

A total of 198 normal eyes were included in this cross-sectional and randomized study. Three measurements were taken using IOPen. Agreement between tonometers was calculated using the Bland and Altman limits of agreement (LoA) analysis.

Results

The median IOPen IOP was 3 mm Hg below the GAT (P<0.001), 3 mm Hg below the ORA IOP similar to Goldmann (IOPg), and 3 mm Hg below the ORA IOP corrected using corneal parameters (IOPcc)(P<0.01). The LoA width between the IOPen and GAT IOPs varied between 13.92 (mean IOPen IOP) and 15.99 mm Hg (third IOPen measurement). The central corneal thickness (CCT) was unrelated to IOPen measurements (P>0.05). Corneal hysteresis (CH) and corneal rigidity factor (CRF) were correlated with IOPen and GAT.

Conclusions

IOPen underestimated the IOP compared with GAT and ORA. The effect of measurement quality or measurement order on IOPen was low. CCT did not affect the IOPen, but the CH and CRF did. The LoA width between the IOPen and GAT IOPs was higher than between the ORA IOPg or ORA IOPcc and GAT IOPs.  相似文献   

5.

AIM

To train Tibetan monkey (Macaca thibetana) for intraocular pressure (IOP) measurement in conscious state and obtain normal IOP in conscious Tibetan Macaque.

METHODS

The training was based on award-conditioned behavior. Food stimulation and human-animal interaction were used in this training.

RESULTS

Trained Tibetan monkeys calmly accepted IOP measurement by the TonoVet® rebound tonometer without sedation or anesthesia and their IOP values were similar to other primates.

CONCLUSION

Human-cultivated Thibetan monkeys are tamable, and can be used for biomedical research such as ophthalmic research without anesthesia.  相似文献   

6.

Purpose

To evaluate the influence of silicone hydrogel contact lenses on the intraocular pressure (IOP) measurement using Goldmann applanation tonometry (GAT), non-contact tonometry (NCT), and Pascal dynamic contour tonometry (DCT).

Methods

We included in the study 40 eyes of 40 patients who did not have any ocular or systemic diseases or contraindications to contact lens use. We measured and recorded the IOP values of each patient using NCT without and with contact lenses (groups 1 and 2, respectively), using DCT without and with contact lenses (groups 3 and 4, respectively), and using GAT without contact lenses (group 5).

Results

The mean IOP value of group 1 was 14.55±2.95 mm Hg and 13.92±2.58 mm Hg in group 2. We detected no statistically significant difference between group 1 and group 2 (P=0.053). The mean IOP values for group 3 and group 4 were 16.26±2.33 mm Hg and 15.19±2.40 mm Hg, respectively. We detected a statistically significant difference between groups 3 and 4 (P=0.005). Group 5''s mean IOP value was 12.97±2.65 mm Hg. IOP values measured with DCT were statistically significantly higher compared with IOP values measured with NCT and GAT (P<0.0001 and P<0.0001, respectively). Additionally, IOP values measured with NCT were statistically significantly higher compared with IOP values measured with GAT (P<0.0001).

Conclusion

According to the results of our study, silicone hydrogel soft contact lens use does not significantly affect IOP values measured with NCT, but it affects IOP values measured with DCT.  相似文献   

7.

Purpose

To compare intraocular pressure (IOP) measurements with Goldmann applanation tonometry (GAT) and iCare tonometry in normal and post-keratoplasty corneas and to assess the influence of central corneal thickness (CCT), corneal curvature (CC), and corneal astigmatism (CA) on IOP.

Methods

This prospective cross-sectional study included one eye of 101 subjects with normal corneas (58 healthy subjects, 43 glaucoma); and 90 post-keratoplasty patients: 34 penetrating keratoplasties (PK); 20 automated-lamellar-therapeutic keratoplasties (ALTK); 19 Descemet-stripping-automated-endothelial keratoplasties (DSAEK); 17 edematous grafts. All subjects underwent GAT and iCare IOP measurements in random order, and CCT, CC, and CA evaluation. The Bland–Altman method and multivariate regression analysis were used to assess inter-tonometer agreement and the influence of CCT, CC, and CA on IOP.

Results

iCare significantly underestimated IOP in all groups compared with GAT (GAT minus iCare of 3.5±3.5 mm Hg, P<0.001), but overestimated IOP in the edematous grafts (GAT minus iCare of −6.5±1.9 mm Hg, P<0.001). In normal corneas, both tonometer measurements were directly related to CCT values; iCare readings appeared inversely related to CC. There was no significant relationship between IOP and CCT, CC and CA in post-keratoplasty eyes, except between CC and iCare measurements for PK eyes.

Conclusions

The agreement between GAT and iCare was clinically acceptable in control, ALTK and DSAEK groups, and poor in PK and edematous grafts eyes. In normal corneas, GAT was significantly affected by CCT; iCare was influenced by CCT and CC. The iCare appeared less influenced by corneal edema when compared with GAT. High IOP readings taken with both tonometers in grafts should raise suspicion of true elevated IOP.  相似文献   

8.

Purpose

To determine whether adjusting corneal hysteresis (CH) values for central corneal thickness (CCT) and intraocular pressure (IOP) improves its capability to differentiate primary open-angle glaucoma (POAG) from ocular hypertension (OH).

Methods

This prospective, observational, cross-sectional study included 169 eyes of 169 subjects with a diagnosis of POAG (n=81) or OH (n=88). We utilized the Ocular Response Analyzer (ORA), Pascal Dynamic Contour Tonometer (DCT), Goldmann applanation tonometer (GAT), and ORA ultrasound pachymeter to obtain CH, IOP, and CCT values. Correlational, regression, and t-test analyses were conducted before and after the sample was divided into low, intermediate, and thick CCT subgroups.

Results

In the full sample, CH and CCT were moderately correlated (r=0.44, P<0.001). Although both were related to diagnosis in univariate regression analysis, only CH was independently related to glaucoma diagnosis in multivariate analysis. After the sample was divided into CCT tertiles, CH was significantly lower in POAG vs OH eyes within all three CCT subgroups, and CH was the only multivariate variable that differentiated POAG from OH in each CCT subgroup. Moreover, the relationship between CH and diagnosis was more robust within the CCT subgroups compared with the full sample, suggesting that integrating CCT into CH interpretation is beneficial. Adjusting CH for IOP did not aid diagnostic precision in this study.

Conclusion

Our findings suggest that combining CH and CCT for glaucoma risk assessment improves diagnostic capability compared to using either factor alone. Conversely, adjusting CH for IOP provided no clear clinical benefit in this study.  相似文献   

9.
AIM: To analyze the correlation of Goldmann applanation tonometer (GAT), I-Care tonometer and Tono-Pen tonometer results in young healthy persons, and to investigate the influence of central corneal thickness (CCT) on intraocular pressure (IOP) measurements recorded with these tonometers. METHODS: We conducted a pilot clinical study in 78 eyes of 78 subjects aged 22-28 years old (44 women and 34 men; mean age 23.8±1.19y). IOP was measured using GAT, I-Care and Tono-Pen tonometers, followed by measurements of CCT. Statistical analysis was performed using SPSS 20.0. RESULTS: The mean IOPs and standard deviation (±SD) for GAT, I-Care and Tono-Pen were 15.62±2.281 mm Hg, 16.29±2.726 mm Hg and 16.32±2.393 mm Hg, respectively. The mean CCT was 555.15±29.648 μm. Clear positive correlations between GAT and I-Care, GAT and Tono-Pen, and I-Care and Tono-Pen tonometers were found (r=0.867, P<0.001; r=0.861, P<0.001; r=0.915, P<0.001, respectively). In comparison between devices, Bland–Altman analysis showed a significant mean difference (MD) in the measurements by GAT and I-Care of ?0.679 mm Hg and by GAT and Tono-Pen of ?0.705 mm Hg ( P<0.001), but there was no significant difference between I-Care and Tono-Pen ( P>0.05). Both non-gold standard tonometers were affected by CCT; that is, both I-Care and Tono-Pen tonometer values were significantly higher with higher CCT means (>555 μm; MD=?1.282, P<0.001; MD=?0.949, P<0.001, respectively) compared with GAT. CONCLUSION: Both I-Care and Tono-Pen tonometers overestimated IOP compared with the GAT values. Either the I-Care or Tono-Pen tonometer could be used instead of GAT because there was no significant difference between their results. Higher CCT values (>555 μm) were associated with overestimated IOP values.  相似文献   

10.

Background

To compare intraocular pressure (IOP) measurements obtained with dynamic contour tonometer (DCT) and Goldmann applanation tonometer (GAT), and to investigate their relationship to central corneal thickness (CCT) in primary congenital glaucoma (PCG) eyes.

Methods

Thirty-one eyes of 31 PCG patients (25.7?±?7.2 years old) were examined. PCG was defined as elevated IOP, enlarged corneal diameter (buphthalmos), Haab’s striae and abnormal findings at gonioscopy. The mean of three measurements of GAT, DCT (quality scores 1 and 2), and CCT were obtained and assessed for agreement by means of Bland–Altman plot and for Spearman correlation test.

Results

Mean CCT was 534?±?72.3 μm (range: 430 to 610 μm). Mean IOP measurements were 15.1?±?4.2 mmHg (range: 5.5 to 22.7 mmHg) for DCT and 14.5?±?5.6 mmHg (range: 7.0 to 34.0 mmHg) for GAT (P?=?0.244). Spearman correlation tests showed that IOP difference (DCT ? GAT) was not correlated with CCT (r 2?=?0.023, P?=?0.417). IOP measurements by DCT were weakly but statistically correlated with those obtained with GAT (r2?=?0.213, P?=?0.0089). Bland–Altman analysis revealed poor agreement between DCT and GAT readings, considering the 95 % confidence intervals of ±10.45 mmHg.

Conclusions

The differences between DCT and GAT readings were not influenced by CCT in this series of patients. Considering the weak correlation and the poor agreement observed between GAT and DCT measurements and that they both may be affected by corneal biomechanical changes, these methods should not be used interchangeably, and may possibly give no meaningful IOP values in PCG patients.  相似文献   

11.
AIM: To investigate the accuracy of intraocular pressure (IOP) as measured by a Reichert Ocular Response Analyzer (ORA), as well as the relationship between central corneal thickness (CCT) and IOP as measured by ORA, Goldmann applanation tonometry (GAT), and dynamic contour tonometry (DCT). METHODS: A total of 158 healthy individuals (296 eyes) were chosen randomly for measurement of IOP. After CCT was measured using A-ultrasound (A-US), IOP was measured by ORA, GAT, and DCT devices in a randomized order. The IOP values acquired using each of the three tonometries were compared, and the relationship between CCT and IOP values were analyzed separately. Two IOP values, Goldmann-correlated IOP value (IOPg) and corneal-compensated intraocular pressure (IOPcc), were got using ORA. Three groups were defined according to CCT: 1) thin cornea (CCT<520μm); 2) normal-thickness cornea (CCT: 520–580μm); and 3) thick cornea (CCT>580μm) groups. RESULTS: In normal subjects, IOP measurements were 14.95±2.99mmHg with ORA (IOPg), 15.21±2.77mmHg with ORA (IOPcc), 15.22±2.77mmHg with GAT, and 15.49±2.56mmHg with DCT. Mean differences were 0.01±2.29mmHg between IOPcc and GAT (P>0.05) and 0.28±2.20mmHg between IOPcc and DCT (P>0.05). There was a greater correlation between IOPcc and DCT (r=0.946, P=0.000) than that between IOPcc and GAT (r=0.845, P=0.000). DCT had a significant correlation with GAT (r=0.854, P=0.000). GAT was moderately correlated with CCT (r=0.296, P<0.001), while IOPcc showed a weak but significant correlation with CCT (r=?0.155, P=0.007). There was a strong negative correlation between CCT and the difference between IOPcc and GAT(r=-0.803,P=0.000), with every 10μm increase in CCT resulting in an increase in this difference of 0.35mmHg. The thick cornea group (CCT>580μm) showed the least significant correlation between IOPcc and GAT (r=0.859, P=0.000); while the thin cornea group (CCT<520μm) had the most significant correlation between IOPcc and GAT (r=0.926, P=0.000). The correlated differences between IOPcc and DCT were not significant in any of the three groups (P>0.05). CONCLUSION: Measurement of IOP by ORA has high repeatability and is largely consistent with GAT measurements. Moreover, the ORA measurements are affected only to a small extent by CCT, and are likely to be much closer to the real IOP value than GAT.  相似文献   

12.

Purpose

To prospectively examine changes in the central visual field (VF) in patients with advanced open-angle glaucoma (OAG) with advanced late stage after trabeculectomy for 12 months.

Design

Prospective interventional case series.

Methods

In all, 27 eyes of 27 OAG patients at a single center with a best-corrected visual acuity (BCVA) of ≥40/200 and a mean total deviation of test locations of the 10-2 program of the Humphrey VF analyzer of ≤−20 dB preoperatively were enrolled. Intraocular pressure (IOP), VF parameters of the 10-2 program, and BCVA were examined for 12 months after trabeculectomy with mitomycin C. Slopes of VF parameters and their correlation with presumed risk factors were studied.

Results

IOP decreased from 19.7±5.8 to 9.7±2.6 mm Hg (P<0.001) over postoperative 1 year. The slopes of all VF parameters did not significantly differ from zero (P>0.33), and none of the presumed factors significantly correlated with the slopes of those parameters (P>0.14). There were two eyes (7%) and one eye (4%) with ≥2 lines of deterioration in BCVA (decimal fraction) at 1 and 12 months, respectively, after surgery with no apparent causes.

Conclusions

Trabeculectomy resulted in little change in the central 10-degree VF, but significant decrease in BCVA without apparent causes might occur approximately 5% of the cases.  相似文献   

13.

Background and Aim:

Resistive index (RI) is an indirect measurement of blood flow resistance that can be used to evaluate vascular damage in ophthalmologic disease. The purpose of this study was to evaluate the association between RI values of orbital arteries using the color Doppler imaging (CDI) in geriatric hypertensive patients with or without retinopathy.

Setting and Design:

Designed as a cross-sectional study.

Materials and Methods:

We evaluated 60 geriatric patients with hypertension (Group 1) and 30 healthy subjects (Group 2). Further, the patients with hypertension were grouped into two: Group 1a consisted of patients with retinopathy (n = 30), and group 1b consisted of patients without retinopathy (n = 30). The mean RI values of ophthalmic artery (OA), central retinal artery (CRA), and posterior ciliary artery (PCA) were measured using CDI.

Results:

Compared to group 2, group 1 had significantly higher mean resistive index of PCA levels (P = 0.017), whereas there were no statistical difference in mean resistive indexes of OA and CRA (both P > 0.05). Besides, there were no statistical difference in mean resistive indexes of OA, CRA, and PCA between the group 1a and group 1b (P > 0.05 for all). Mean resistive indexes of OA, CRA, and PCA were significantly correlated with the duration of hypertension (r = 0.268, P = 0.038; r = 0.315, P = 0.014; r = 0.324, P = 0.012, respectively).

Conclusions:

Our study indicates that RI might be a useful marker for the ocular hemodynamic of retinal vessels, provides morphologic and vascular information in hypertension and hypertensive retinopathy.  相似文献   

14.

Aim

To describe the outcome of using diode laser transscleral cyclophotocoagulation (cyclodiode laser) as a safe technique in managing acute angle closure refractory to conventional treatment.

Methods

This is a retrospective case series from two ophthalmic units in the United Kingdom. Five patients with acute angle closure refractory to medical and laser treatment underwent cyclodiode laser treatment. Demographic information, symptoms, medical and surgical treatment, visual outcomes, and intraocular pressure (IOP) control were recorded.

Case reports

All five patients had symptomatic acute angle closure. Conventional management, including topical and systemic medical treatment, laser iridotomy and laser iridoplasty, did not achieve adequate IOP control or relieve symptoms. Emergency cyclodiode laser treatment was performed within 2–23 days of presentation. All patients subsequently required lensectomy at a later date. At final follow-up (6–14 months), all patients had visual acuity of 6/12 or better with well-controlled IOPs (≤17 mm Hg). Only one patient was on topical treatment. One patient developed a persistent low-grade anterior uveitis.

Discussion

Cyclodiode laser is a safe alternative to emergency lensectomy or trabeculectomy in cases of acute angle closure, which do not respond to treatment.  相似文献   

15.

Purpose

To compare the accuracy of intraocular lens (IOL) power calculation formulas in eyes with primary angle closure glaucoma (ACG).

Methods

This retrospective study compared the refractive outcomes of 63 eyes with primary ACG with the results of 93 eyes with normal open angles undergoing uneventful cataract surgery. Anterior segment biometry including anterior chamber depth, axial length, and anterior chamber depth to axial length ratio were compared by the IOL Master. Third generation formulas (Hoffer Q and SRK/T) and a fourth generation formula (Haigis) were used to predict IOL powers in both groups. The predictive accuracy of the formulas was analyzed by comparison of the mean error and the mean absolute error (MAE).

Results

In ACG patients, anterior chamber depth and the anterior chamber depth to axial length ratio were smaller than normal controls (all p < 0.05). The MAEs from the ACG group were larger than that from the control group in the Haigis formula. The mean absolute error from the Haigis formula was the largest and the mean absolute error from the Hoffer Q formula was the smallest.

Conclusions

IOL power prediction may be inaccurate in ACG patients. The Haigis formula produced more inaccurate results in ACG patients, and it is more appropriate to use the Hoffer Q formula to predict IOL powers in eyes with primary ACG.  相似文献   

16.

Purpose

Anatomically, the eyes and paranasal sinuses are neighboring structures and some studies have mentioned eye disease in conjunction with chronic rhinosinusitis (CRS). However, to the best of our knowledge, no prior research has investigated the risk of developing open-angle glaucoma (OAG) among CRS patients. This study aims to provide an estimated risk of developing OAG among patients with CRS by using a population-based data set in Taiwan.

Methods

This retrospective cohort study used data sourced from the ‘Longitudinal Health Insurance Database 2000''. A total of 15 642 CRS patients were included in the study cohort and 46 926 subjects were randomly extracted as a comparison cohort. A cox proportional-hazards regression analysis was performed to calculate the 5-year risk of subsequently developing OAG following a diagnosis of CRS between the study cohort and the comparison cohort.

Results

The incidence rate of developing OAG over the 5-year follow-up period was 5.45 (95% CI: 4.95–5.98) per 1000 person-years for the study cohort and 2.80 (95% CI: 2.60–3.03) per 1000 person-years for the comparison cohort. After censoring the cases that died over the 5-year period and adjusting for the factors of monthly income, geographic region, hypertension, diabetes, coronary heart disease, hyperlipidemia, and hypothyroidism the hazard ratio for developing OAG over the 5-year period for subjects with CRS to subjects without CRS was 1.73 (95% CI: 1.53–1.96).

Conclusion

We found that those subjects with CRS had a significantly higher risk of developing OAG over the 5-year follow-up period as compared with subjects without CRS.  相似文献   

17.

Purpose

To evaluate whether retrobulbar blood flow and choroidal thickness (CT) are affected in patients with rheumatoid arthritis (RA), and the relationship between these values.

Methods

We evaluated 40 eyes of 20 RA patients and 40 eyes of 20 healthy controls. The enhanced depth imaging optical coherence tomography, color Doppler imaging, was held. Statistical analysis was performed.

Results

Peak systolic velocity (PSV) of ophthalmic (OA) and central retinal artery (CRA) were significantly higher in RA. No significant difference was observed when end-diastolic velocity (EDV) of OA and CRA was compared between the groups. The resistivity index (RI) of OA and CRA was higher in RA. Perifoveal/subfoveal CT was lower in RA. Negative correlation was detected between the RI of OA and the perifoveal CT, and a positive correlation was detected between RI of CRA and CT.

Conclusions

Ocular hemodynamics is effected by RA and can exaggerate ocular complications of various vascular diseases such as diabetes mellitus, hypertension, retinal vascular occlusions.
  相似文献   

18.
AIM: To evaluate the efficacy and tolerability of the fixed combination of bimatoprost 0.03% and timolol 0.5% (BTFC) in patients in Greece with primary open angle glaucoma (POAG) or ocular hypertension (OHT) whose previous therapy provided insufficient lowering of intraocular pressure (IOP). METHODS: A multicenter, prospective, open-label, non-interventional, observational study of the use of BTFC in clinical practice was conducted at 41 sites in Greece. The primary endpoint was the reduction in IOP from baseline at study end, approximately 12wk after initiation of BTFC therapy. RESULTS: A total of 785 eligible patients were enrolled in the study and 97.6% completed the study. The mean±SD IOP reduction from baseline at 12wk after initiation of BTFC was 6.3±2.8 mm Hg (n=764; P<0.001). In patients (n=680) who replaced their previous IOP-lowering monotherapy (a single drug, or a fixed combination of 2 drugs in a single ophthalmic drop) with once-daily BTFC, the mean±SD IOP reduction from baseline at 12wk was 6.2±2.8 mm Hg (P<0.001). IOP was reduced from baseline in 99.2% of patients, and 58.0% of patients reached or exceeded their target IOP. Substantial mean IOP reductions were observed regardless of the previous therapy. BTFC was well tolerated, with 96.0% of patients who completed the study rating the tolerability of BTFC as “good” or “very good.” Adverse events were reported in 8.3% of patients; only 0.6% of patients discontinued the study due to adverse events. CONCLUSION: In clinical practice in Greece, BTFC is well tolerated and effectively lower the IOP in patients with POAG or OHT who requires additional IOP lowering on their previous therapy.  相似文献   

19.

Purpose

To evaluate the efficacy of a monocular drug trial in eyes with normal-tension glaucoma (NTG).

Methods

This prospective study enrolled 74 patients with NTG. The monocular drug trial was started using latanoprost 0.005% for one week. If the intraocular pressure (IOP) reduction was greater than 15%, the same medication was administered to both eyes for one month. The unadjusted change and adjusted change (the change in the treated eye minus the change in the contralateral eye) in IOP were evaluated, and the predictors of IOP response were analyzed by multivariate linear regression.

Results

Among the initial 74 patients, 31 (41.9%) were included; others were excluded because they did not meet the requisite conditions. The most significant predictors of IOP response in the initial eye and subsequent eye were the baseline IOPs in both eyes (β = 0.907, 0.771, respectively). The adjusted change in IOP of the initial eye had greater association (β = 0.589) with the IOP after monocular trial in the initial eye than that of unadjusted IOP change (β = 0.279). The adjusted change in IOP also had greater predictability (β = 0.348) for IOP after monocular trial in the subsequent eye than that of the unadjusted IOP change (β = 0.090).

Conclusions

Although the monocular trial in NTG patients had limited efficacy due to its stringent conditions, it was useful for evaluating the IOP response in the initial eye and for predicting the IOP response in the subsequent eye.  相似文献   

20.

Purpose

To identify the prognostic factors for successful laser iridotomy for acute angle-closure glaucoma (AACG).

Methods

We retrospectively reviewed the medical records of 77 eyes of 77 patients with AACG with initial intraocular pressure (IOP) above 40 mmHg. All of the patients received maximum tolerable medical therapy (MTMT) followed by laser iridotomy. In order to comparatively analyze the factors affecting successful laser iridotomy, an increase in IOP on follow-up was defined as increase in IOP greater than 21 mmHg requiring medical or surgical treatment.

Results

Successful laser iridotomy was achieved in 59.7% (46/77 eyes). Thirty-one eyes (40.3%) exhibited increased IOP on follow-up, and of these, 30 eyes developed an increase in IOP within six months after the first attack. The success rate was higher (92.9%) in 42 patients who had greater than 30% IOP reduction by MTMT at the first attack compared to the 35 patients whose IOP reduction was less than 30%, of which 24 eyes (72.7%) showed more than 30% IOP reduction after intravenous hyperosmotic agent treatment (p=0.012). The success rate was higher in patients treated within seven days after the development of symptoms than in those treated after seven days (Odds ratio, 4.51; 95% confidence interval, 1.38 to 14.75).

Conclusions

Our data suggest that we can expect successful IOP control after laser iridotomy in eyes with AACG if the patient can be treated within seven days after the development of symptoms and if the IOP reduction was more than 30% by MTMT.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号