背景:目前计算机辅助导航技术已经越来越多地应用于全膝关节置换中。计算机辅助导航全膝关节置换是否比传统全膝关节置换更具优势目前尚无定论。目的:系统评价计算机辅助导航和传统全膝关节置换后肢体和假体力线的恢复情况。方法:计算机检索2013年6月前PubMed/Medline、EMBASE、Cochrane CENTRAL、ScienceDirect数据库,纳入计算机辅助导航和传统全膝关节置换的随机对照试验,应用Cochrane协作网提供的RevMan 5.2.5软件进行Meta分析。选取髋-膝-踝机械轴或胫股关节角、股骨假体冠状角、股骨假体矢状角、胫骨假体冠状角、股骨假体矢状角5个指标进行比较,以偏离中线2°或3°确定为力线不良。结果与结论:共纳入19篇随机对照试验文献,共2 654例(3 392膝)。Meta分析结果显示,计算机辅助导航全膝关节置换后机械轴恢复精确率明显优于传统全膝关节置换,其中偏倚3°时,P0.000 01;偏倚2°时,P=0.000 8。计算机辅助导航全膝关节置换后股骨假体冠状角恢复精确率(3°)明显优于传统全膝关节置换(P=0.002);偏倚2°时两种方案差异无显著性意义(P=0.290)。计算机辅助导航全膝关节置换后股骨假体矢状角恢复精确率(3°)明显优于传统全膝关节置换(P=0.040);偏倚2°时两种方案差异无显著性意义(P=0.950)。计算机辅助导航全膝关节置换后胫骨假体冠状角恢复精确率明显优于传统全膝关节置换,偏倚3°时,P=0.000 7;偏倚2°时,P=0.002。计算机辅助导航全膝关节置换后股骨假体矢状角恢复精确率(3°)明显优于传统全膝关节置换(P=0.030);偏倚2°时两种方案差异无显著性意义(P=0.260)。提示计算机辅助导航全膝关节置换后肢体力线、股骨/胫骨假体力线偏倚3°以内的精确率均优于传统全膝关节置换,但股骨假体冠状角、股骨假体矢状角、股骨假体矢状角偏倚2°以内的精确率两种方案无明显差异。  相似文献   

2.
文题释义: 运动力学对线:是行全膝关节置换时的一种下肢对线方法,尽可能还原膝关节患关节炎前的运动状态。 机械力学对线:该对线方法已指导全膝关节置换手术近30年,机械力学对线技术的目标是恢复髋-膝-踝0°角,从而使整个下肢恢复到中立位,近些年研究发现该方法指导的全膝关节置换术后1/5患者对置换效果不满意。 背景:机械力学对线技术虽然保证了膝关节假体的长期生存率,但是仍有部分全膝关节置换患者对置换效果及术后膝关节功能不满意。 目的:采用Meta分析的方法评价运动学对线技术和机械力学对线技术指导全膝关节置换的效果。 方法:检索运动学对线和机械力学对线指导全膝关节置换的临床对照研究文献,检索范围包括中国生物医学文献数据库、万方数据、中国知网、维普数据、PubMed、Cochrane图书馆及Embase,检索年限为建库日期至2019年7月。对检索到的文献进行筛选、质量评价及数据提取,并采用Review Manager 5.3软件进行统计分析。 结果与结论:①共纳入12篇文献,包括945例患者,其中运动学对线组470例,机械力学对线组475例;②荟萃分析结果显示,手术时间方面运动学对线组比机械力学对线组更短[MD=-15.44,95%CI(-27.16,-3.71)],西安大略和麦克马斯特大学骨关节炎指数运动学对线组优于机械力学对线组[MD=-8.40,95%CI(-15.39,-1.40)],牛津大学膝关节评分运动学对线组优于机械力学对线组[MD=4.72,95%CI(0.24,9.21)],机械力学对线组术后的机械外侧股骨远端角及机械内侧胫骨近端角显著大于运动学对线组,以上研究P均< 0.05;③运动学对线组与机械力学对线组在平均住院日、出院前最远行走距离、膝关节协会评分、膝关节伸直角度、术后并发症方面差异无显著性意义(P均> 0.05);④提示运动学对线指导全膝关节置换后的膝关节功能优于机械力学对线,但影像学和围术期结果类似,且术后未增加并发症发生率。说明运动学对线可作为一种下肢力线对线方法来指导全膝关节置换。 ORCID: 0000-0002-3786-6305(赵春涛) 中国组织工程研究杂志出版内容重点:人工关节;骨植入物;脊柱;骨折;内固定;数字化骨科;组织工程  相似文献   

3.
目的 探讨临床数字化导航模板辅助全膝关节置换的可行性和准确性。 方法 招募20例(男8例,女12例)膝骨性关节炎患者。采集患者下肢全长MRI扫描数据,利用逆向工程软件对MRI数据进行处理,计算机内设计得到一款与股骨远端和胫骨近端匹配的可定位截骨平面和外旋轴的导航模板,最后通过快速成型机制作模板实物用于临床手术操作。手术由同一位具有关节置换经验的骨科医生行全膝关节置换手术。术前观察导航模板与股骨髁和胫骨平台匹配性,术后通过CT扫描检测截骨的准确性。 结果 导航模板与股骨髁和胫骨平台贴合紧密,无明显移动;所有患者股骨远端和胫骨近端截骨面与下肢机械轴基本垂直,外旋轴定位精确,股骨后髁截骨面与通髁轴保持平行。 结论 数字化导航模板辅助全膝关节置换具有安全可行,手术操作简单,截骨力线准确。  相似文献   

4.
文题释义:单髁假体置换:为人工膝关节置换的一个特殊类型,是一种置换范围局限在单侧髁的置换。膝单髁关节置换与全膝关节置换几乎同时起步于20世纪70年代初期,单髁关节置换的目的是尽可能地保留正常的关节结构,以期获得更好的功能恢复,目前临床上单髁假体有活动平台和固定平台两种单髁假体。下肢机械轴位置Kennedy和White分布:把胫骨平台分为0、1、2、C、3、4、5几个区域,观察股骨头中心—踝关节中心连线经过胫骨平台的区域。KENNEDY和WHITE的研究发现,单髁置换后下肢机械轴经过2、C区的术后效果好,并发症少。背景:单髁置换假体主要分为活动平台和固定平台2种类型,由于两种平台假体的设计理念和手术操作方法上的不同,对于两种平台假体的选择还有一定分歧和争议。 目的:比较活动与固定平台单髁假体置换治疗膝关节内侧间室骨性关节炎的临床效果。 方法:选择2014年2月至2015年2月佛山市中医院收治的单侧膝关节内侧间室骨关节炎患者154例,男54例,女100例,年龄56-81岁,其中100例接受活动平台单髁假体置换治疗(活动平台组),54例接受固定平台单髁假体置换治疗(固定平台组)。记录并发症发生情况。术后随访膝关节目测类比评分、膝关节活动度、膝关节功能与临床KSS评分,复查X射线片(胫股角、髋-膝-踝角度、胫骨后倾角)评估下肢力线矫正情况。研究符合佛山市中医院对研究的相关伦理要求(fsz20130642)。结果与结论:①154例患者术后获得60-72个月的随访;②两组末次随访的膝关节目测类比评分、膝关节活动度、膝关节功能与临床KSS评分均较术前明显改善(P < 0.05),两组间比较差异无显著性意义(P > 0.05);③两组末次随访的胫股角、髋-膝-踝角度、胫骨后倾角均较术前明显改善(P < 0.05),活动平台组胫股角与髋-膝-踝角度的矫正值大于固定平台组(P < 0.05),两组间胫骨后倾角矫正值比较差异无显著性意义(P > 0.05);两组间下肢机械轴位置Kennedy和White分布比较差异无显著性意义(P > 0.05);④活动平台组出现1例假体松动,2例衬垫脱位;⑤结果表明,两种平台单髁置换假体治疗膝关节内侧间室骨性关节炎的中期随访临床结果无明显差异,但活动平台单髁假体置换下肢力线矫正角度较固定平台大,对于恢复下肢解剖轴线更有优势;2种单髁假体术后并发症发生率均较低,活动平台单髁置换后中期随访并发症发生率高于固定平台,活动平台中期并发症主要是假体松动、衬垫脱位。ORCID: 0000-0001-9062-8026(刘少华) 中国组织工程研究杂志出版内容重点:人工关节;骨植入物;脊柱;骨折;内固定;数字化骨科;组织工程  相似文献   

5.
背景:近年来,计算机导航技术辅助关节置换逐渐受到医疗领域的关注。文献报道计算机导航在全膝关节置换中的应用临床效果不一。为了探索新一代Brainlab Knee 3导航系统的临床效果,进行了此项研究。目的:分析计算机导航系统(Brainlab Knee 3)结合间隙平衡技术在全膝关节置换中的应用效果。方法:2020年11月至2021年5月大连市第二人民医院关节外科收治71例行全膝关节置换患者,导航组35例,术中采用计算机导航结合间隙平衡技术行全膝关节置换;传统组36例,术中采用传统手术器械定位截骨。比较两组患者术中内、外侧关节间隙差;膝关节活动度、 KSS评分;髋膝踝角;冠状面股骨组件角、冠状面胫骨组件角和矢状面胫骨组件角偏差值。结果与结论:(1)导航组伸直位内外侧间隙差0,1,2 mm的患者分别为19,14,2例;屈膝90°位内外侧间隙差0,1,2 mm的患者分别为18,15,2例。传统组伸直位内外侧间隙差0,1,2mm的患者分别为10,20,6例;屈膝90°位内外侧间隙差0,1,2mm的患者分别为10,15,8例。(2)导航组手术时间长于传统组(P <0.05),导航组有2例患...  相似文献   

6.
背景:膝关节的解剖形态个体差异显著,而传统膝关节置换手术定位力线方法复杂,不能准确预测术中患者的力线位置、假体大小及截骨量。 目的:探讨基于医学图像三维重建、计算机辅助设计技术以及3D打印制造的个性化手术导航模板辅助下全膝关节置换的临床效果。 方法:采用CT或者磁共振扫描设备对患者进行扫描,获取患者医学图像数据;采用二维医学图像处理技术进行骨骼的三维重构;利用计算机辅助设计技术进行导航模板的设计;采用3D打印技术制造个性化手术导航模板,并进行临床全膝关节置换;置换后采用影像学评估术后效果。 结果与结论:Arigin 3D Pro(昕健医疗技术有限公司)能够准确重构出患者下肢骨骼三维模型,自主研发的三维设计软件Arigin Surgical Templating(昕健医疗)能够精确定位包括下肢力线、股骨旋转轴等在内的下肢相关轴线及截骨参考点。该组研究设计和制作的个性化膝关节手术导航模板,术中和股骨髁与胫骨平台骨性解剖结构贴合紧密,无明显移动;全膝关节置换后患者下肢力线偏差小于3°。 中国组织工程研究杂志出版内容重点:人工关节;骨植入物;脊柱;骨折;内固定;数字化骨科;组织工程  相似文献   

7.
背景:计算机辅助导航能否提高全膝关节置换假体的精确性及临床效果,一直存在很大争议。目的:对国内外有关计算机辅助导航全膝关节置换的研究文献进行Meta分析,评价计算机辅助导航全膝关节置换与传统技术临床疗效的差异。方法:计算机检索PubMed,Ovid,Elsevier,CNKI、数字图书馆等数据库,检索2005-01-01/2013-12-31有关计算机辅助导航与传统全膝关节置换临床效果随机对照试验的文献资料。采用Cochrane协作网提供的RevMan 5.0软件进行Meta分析,比较计算机辅助导航全膝关节置换与传统技术的临床疗效,并对数据进行异质性检验。结果与结论:共纳入符合设计标准的16篇随机对照试验文献,导航组1 322膝,传统组1 299膝,导航组下肢力线内翻或外翻大于2°和3°的发生率、股骨胫骨假体冠状位对线内翻或外翻角大于3°的发生率、股骨假体矢状位对位线大于3°的发生率、胫骨后倾角大于3°的发生率均低于传统组。在胫骨假体矢状位对位线、股骨、胫骨假体内外旋转角度和并发症发生率两组差异无显著性意义。提示导航组能带来更佳的下肢力线和假体位置,但还需更多研究来提高远期效果。  相似文献   

8.
背景:目前,在全膝关节置换时无论是使用活动衬垫还是固定衬垫,全膝关节置换后中长期的功能转归和再手术率都相同,但是近期患膝关节功能改善情况各专家意见并不一致。目的:分析活动衬垫型与固定衬垫型假体全膝关节置换后膝关节相关活动的角度变化,以探讨置换后关节活动的改善情况。方法:选择2005年1月至2012年12月确诊为膝关节骨关节炎且患膝既往无手术史的患者90例,应用固定衬垫型假体或活动衬垫型假体进行全膝关节置换治疗。测量患者置换前膝关节活动度,置换后股骨角、胫骨角、膝外翻角、胫骨平台后倾角、髌骨高度。结果与结论:置换后随访4-36个月,末次随访时活动衬垫组的最大屈曲度大于固定衬垫组,差异有显著性意义(P<0.05)。末次随访时两组的股骨角、胫骨角、膝外翻角、胫骨平台后倾角比较,差异无显著性意义(P>0.05)。置换前后髌骨高度比较,差异无显著性意义(P>0.05)。说明活动衬垫型和固定衬垫型假体全膝关节置换后近期患膝关节功能明显改善,且活动衬垫型效果更令人满意。  相似文献   

9.
文题释义:ROM技术:其原理是先固定股骨假体,然后安放胫骨假体试模而不固定,使胫骨假体试件在股骨假体的引导下进行旋转位置的自我调整,达到胫骨平台自然的与股骨假体结合并处于最合适位置的目的,该技术是目前临床上定位胫骨假体旋转力线较为常用的方法,但据文献报道,该技术确定的胫骨假体旋转力线可能存在误差。 膝关节置换:经历了150年的演变史,目前已经成为晚期骨性关节炎患者的主要治疗措施。根据膝关节置换部位可分为单间室置换(单髁置换)、双间室置换(膝关节内外间室)、髌股关节置换及三间室置换(内外间室及髌股间室)。国内运用最多的为膝关节双间室置换,常用的术式包括后交叉韧带替代型和后交叉韧带保留型双间室置换,多数文献认为选择哪一种手术方式对患者的长期疗效无显著差异。 背景:ROM技术是膝关节置换过程中确定胫骨假体旋转力线的常用方法,但该技术的准确性仍存在争议,目前ROM技术可能的影响因素尚未见报道。 目的:探讨膝关节置换过程中运用ROM技术确定胫骨假体旋转力线的影响因素。 方法:纳入61例初次接受单侧膝关节置换的患者,男18例,女43例,年龄55-78岁,术前均诊断为膝关节骨性关节炎,所有手术均采用后稳定型膝关节假体。所有患者对治疗方案均知情同意,且得到医院伦理委员会批准。根据ROM技术确定闭合与未闭合内侧支持带时胫骨假体旋转轴线,同时定位后交叉韧带止点中点与髌韧带内侧缘连线(Akagi线)作为参考线,测量2种情况下ROM技术确定的胫骨假体旋转轴线与Akagi线的相对位置关系,术中判断髌骨轨迹分型,从而确定髌骨轨迹分型及闭合内侧支持带与否是否为ROM技术的影响因素。 结果与结论:①术中出现Ⅰ,Ⅱ及Ⅲ型髌骨轨迹时,未闭合内侧支持带时ROM技术确定的胫骨假体旋转轴线与Akagi线之间的夹角分别为(0.5±2.5)°,(-0.9±2.6)°及(-3.9±3.4)°;闭合内侧支持带时夹角分别为(0.6±2.3)°,(-0.3±2.2)°及(-1.5±2.9)°;② Ⅲ型髌骨轨迹可导致ROM技术确定的胫骨旋转轴线与Akagi线之间的夹角明显偏内(P < 0.05);③对于Ⅰ,Ⅱ型髌骨轨迹,是否闭合内侧支持带对ROM技术确定的胫骨假体轴线无明显影响(P > 0.05);对于Ⅲ型髌骨轨迹,闭合内侧支持带可明显减小ROM技术确定的胫骨假体旋转轴线与Akagi线之间的差异(P < 0.05);④结果提示,ROM技术对Ⅰ,Ⅱ型髌骨轨迹的全膝关节置换能够较准确地定位胫骨假体的旋转轴线,无需闭合内侧支持带;出现Ⅲ型髌骨轨迹时,无论是否闭合内侧支持带都可能造成胫骨假体过度内旋。 ORCID: 0000-0002-7360-1881(李叶天) 中国组织工程研究杂志出版内容重点:人工关节;骨植入物;脊柱;骨折;内固定;数字化骨科;组织工程  相似文献   

10.
文题释义:人工膝关节置换:是指利用金属、高分子聚乙烯等材料,根据人体膝关节形态、受力及功能制成人工关节假体,通过外科技术将假体植入人体内。人工膝关节置换是治疗重度膝关节骨关节炎的最佳手段,能够有效减轻患者肢体疼痛,改善关节活动度及功能,提高患者生活质量。 夜间手术:大部分膝关节置换患者是在三级医院接受手术治疗的,但由于膝关节置换患者的快速增多,以及医院的手术房间、外科医生、麻醉医师数量的限制,部分患者会在夜间(18:01-7:59)接受常规人工膝关节置换手术治疗。 背景:对于夜间行手术治疗是否会影响患者安全及预后一直存在争议。 目的:对比白天与夜间手术行全膝关节置换的安全性与预后差异。 方法:回顾性分析2015年1月至2018年1月在滨州医学院附属医院接受单侧全膝关节置换712例患者的资料,其中615例在白天(8:00-18:00)接受全膝关节置换治疗,97例在夜间(18:01-7:59)接受全膝关节置换治疗。比较两组的围术期及预后情况。试验获得滨州医学院附属医院伦理委员会批准,批准号:LW2016013。 结果与结论:①围术期:夜间手术组手术时间短于白天手术组(P < 0.05),术中出血量与术后24 h引流量多于白天手术组(P < 0.05);两组术后输血率、术后深静脉血栓发生率、术后感染率、术后假体周围感染率、术后发热率、术后住院时间比较差异均无显著性意义(P > 0.05);②预后:两组术后7 d、1个月、3个月、1年的膝关节活动度与膝关节功能KSS评分比较差异均无显著性意义(P > 0.05);③结果表明:夜间手术未增加全膝关节置换后的不良反应发生率,不影响患者的预后。 ORCID: 0000-0001-9160-451X(杜长岭) 中国组织工程研究杂志出版内容重点:人工关节;骨植入物;脊柱;骨折;内固定;数字化骨科;组织工程  相似文献   

11.
文题释义: 单髁置换:指对仅存在单间室病变膝关节的一种置换手术方式,用以替代膝关节胫股关节破坏的软骨表面,具有微创手术的优势,例如创伤小、恢复快、截骨少、费用低、手术时间短等优点。理论上,单髁置换后患者的膝关节活动度较好,且膝关节功能接近生理状态。 后交叉韧带保留型假体:全膝关节置换术中一种较为成熟的假体,术中保留了膝关节后交叉韧带且不进行髁间窝截骨,比较符合膝关节的解剖特性,手术难度虽然较大,但保留了较多的膝关节正常生理结构,有较好的膝关节稳定性,假体的松动率亦较低。背景:针对仅存在膝关节内侧间室病变的患者,单髁置换与后交叉韧带保留型全膝关节置换均是有效的治疗方式,但对于居住于山区的中老年人的近期疗效需进一步探索。 目的:探讨单髁置换与后交叉韧带保留型假体置换治疗承德地区中老年人膝关节内侧间室骨关节炎的近期疗效。 方法:选择2017年1月至2019年2月在承德医学院附属医院关节外科接受手术治疗的内侧间室膝关节炎中老年患者67例,其中A组31例行单髁置换,B组36例行后交叉韧带保留型假体全膝置换。所有患者对治疗方案均知情同意,且得到医院伦理委员会批准。观察比较2组患者术中出血量、术后输血情况、术后血红蛋白下降值,术后1,3 d红细胞容积、C-反应蛋白,术后第1,3,6个月及1年的关节遗忘评分。 结果与结论:①A组围术期血红蛋白下降值、术中出血量、输血率均低于B组,术后住院时间短于B组,差异有显著性意义(P < 0.05);②术后第1,3天2组的C-反应蛋白水平差异无显著性意义(P > 0.05);③A组术后第1,3,6月及1年的关节遗忘评分均高于B组,差异有显著性意义(P < 0.01);④2组术后均未发生下肢深静脉血栓、肺栓塞及感染等并发症;⑤综上,单髁置换在治疗仅存在内侧间室病变膝关节炎的山区中老年患者时,具有术中出血少、输血率低、关节遗忘程度高等优点。 ORCID: 0000-0002-8983-8293(韩梦光) 中国组织工程研究杂志出版内容重点:人工关节;骨植入物;脊柱;骨折;内固定;数字化骨科;组织工程  相似文献   

12.
BackgroundHip-to-calcaneus (HC) view is a whole-leg standing view that can visualize the hindfoot in detail. The aim of this study was to investigate the reliability and validity of tibiocalcaneal angle in HC view (H-TCA) by comparing it with that in long axial view (L-TCA). We also verified whether periarticular knee alignment parameters, measured conventionally in whole-leg standing radiography, could be measured in HC view.MethodSixty healthy volunteers and 61 patients with medial knee osteoarthritis were included. H-TCA was measured by two examiners in the healthy group, and intra-class correlation coefficients (ICCs) were evaluated. H-TCA and L-TCA were then measured in the healthy and osteoarthritis groups and correlated. Finally, we measured hip–knee–ankle angle, mechanical axis deviation ratio, mechanical lateral distal femoral angle, medial proximal tibial angle, and joint-line convergence angle in HC view and conventional whole-leg standing radiography to evaluate statistical differences and correlations.ResultsThe intra-observer and inter-observer ICCs were 0.86 and 0.76, respectively. Correlation coefficients (r) between H-TCA and L-TCA were r = 0.87 in healthy group and r = 0.81 in osteoarthritis group, indicating a strong positive correlation in both groups. There was no significant difference in periarticular knee alignment parameters between HC view and conventional whole-leg radiography.ConclusionsHindfoot evaluation in HC view showed high intra-observer and inter-observer reliabilities and strong positive correlation with TCA in long axial view. By using HC view before knee surgery, such as total knee arthroplasty, other necessary alignments can be evaluated simultaneously.  相似文献   

13.
文题释义: 隐性失血:一般是指较大的创伤或手术后,排除手术创面失血、术中及术后引流丢失等可计算的显性失血之外,患者机体内丢失的血量。试验中由于所有患者术后均未放置引流管,未观察到显性失血,所以术后第4,21,42天的总失血量为隐性失血量,用血红蛋白和红细胞比容数值变化来体现隐性失血的变化。 显性失血:一般是指较大的创伤或者手术后,手术创面失血、术中及术后引流丢失等可计算的失血量。 背景:单髁置换相较于全膝关节置换的术中失血量相比较低,但二者之间的术后隐性失血量差异尚未得到广泛研究。 目的:对比单髁置换与全膝关节置换后隐性失血的差异,分析术前贫血患者是否也可以在无输血风险的情况下进行单髁置换手术。 方法:选择2014年1月至2016年12月联勤保障部队第904医院收治的膝关节骨性关节炎患者148 例,其中58例进行单髁置换手术,90例进行全膝关节置换手术。术前及术后第1,4,21,42天,检测两组血红蛋白水平、红细胞比容,计算隐性失血量与输血率。试验获得联勤保障部队第904医院伦理委员会批准,批准号:2019-01-03。 结果与结论:①单髁置换组术后第1,4天的血红蛋白水平高于全膝关节置换组(P < 0.01),两组术前及术后21,42天的血红蛋白水平比较差异无显著性意义(P > 0.05);②单髁置换组术后第1,4天的红细胞比容高于全膝关节置换组(P < 0.01),两组术前及术后21,42天的红细胞比容比较差异无显著性意义(P > 0.05);③在术后第1,4天之间,单髁置换组中女性没有隐性失血,男性平均血红蛋白下降量为 4 g/L;全膝关节置换组中女性平均血红蛋白下降量为 10 g/L,男性为 7 g/L,单髁置换组男性与女性的隐性失血量均低于全膝关节置换组的对应性别患者(P < 0.05或P < 0.01);④单髁置换组的输血率为0%,全膝关节置换组的输血率为4.4%;术前中度贫血的患者(血红蛋白60-89 g/L),单髁置换组3例均无需输血,而全膝关节置换组6例中2例(33%)需输血;⑤结果表明,单髁置换较全膝关节置换在术后隐性失血方面有明显优势。 ORCID: 0000-0002-7314-5548(彭超) 中国组织工程研究杂志出版内容重点:人工关节;骨植入物;脊柱;骨折;内固定;数字化骨科;组织工程  相似文献   

14.
BACKGROUND: Computer assisted navigation has been applied in total knee arthroplasty, can make the prosthesis more accurately implanted, play a good role in navigation, and enhance accuracy of knee prosthesis rotation power lines. Computer-assisted navigation system appears lately in China, so few studies concern the location of total knee arthroplasty and its application in soft tissue balance. OBJECTIVE: To investigate the application of computer navigation aids located in artificial total knee arthroplasty and soft tissue balance. METHODS: A total of 40 patients (49 knees) who received total knee arthroplasty in Department of Orthopeadic Surgery of Jincheng People’s Hospital from January to September 2015 were analyzed. The patients were divided into conventional surgery group (20 cases, 24 knees) and navigation group (20 cases, 25 knees). The patients in the conventional surgery group were positioned with intramedullary femoral alignment bar and extramedullary tibial alignment bar. In the navigation group, total knee arthroplasty was performed in accordance with computer. Repair of incision and approach in both groups were identical. Positioning effect and effect of computer assisted navigation on soft tissue balance in total knee arthroplasty were analyzed. RESULTS AND CONCLUSION: (1) Operation time was longer significantly in the navigation group than in the conventional surgery group (P < 0.05). Blood loss and 24-hour drainage volume were significantly less in the navigation group than in the conventional surgery group (P < 0.05). (2) Range of motion of the knee and Hospital for Special Surgery score were significantly higher in the navigation group than in the conventional surgery group (P < 0.05). Power line error, soft tissue balance angle variable and soft tissue balance separation variables were significantly less in the navigation group than in the conventional surgery group (P < 0.05). (3) These results confirmed that computer navigation aids in total knee arthroplasty obtained ideal effect, ensured more accurate prosthesis implantation, better limb alignment, and ensured soft tissue balance. However, the computer-assisted navigation will increase operation time. For its application, we should consider the pros and cons.     相似文献   

15.
BackgroundThe sagittal spinal alignment interacts with the lower extremity in patients with combined degenerative disease of the spine and lower extremity. This study aimed to clarify the relationships between the reciprocal changes in sagittal alignment of the knee, pelvis, and spine after total knee arthroplasty (TKA) in osteoarthritis patients.MethodsProspectively, 36 patients who underwent primary TKA for severe knee osteoarthritis were enrolled. Their clinical and radiological evaluation included assessments of the knee flexion contracture (KFC) and standing knee flexion angle (KFA), as well as spinopelvic parameters and the global sagittal spinal alignment from standing whole-lower-extremity and whole-spine radiographs preoperatively and at postoperative 2 weeks, 6 weeks, 6 months, 1 year, and 2 years. Linear mixed models were used to assess the relationships between KFC/KFA and between spinopelvic/global sagittal spinal alignments.ResultsThe KFC decreased abruptly immediately after TKA, and the correction was maintained for 2 years postoperatively. The KFA decreased gradually and approached the value of the KFC after 2 years. Of the spinopelvic parameters, sacral slope and pelvic incidence decreased significantly, in ways related to changes in KFA. There was no significant relationship between sagittal spinal alignment and postoperative changes in KFC.ConclusionAlthough the flexion contracture was corrected immediately after TKA, the standing KFA improved gradually over 2 years. The pelvic parameters showed compensatory changes according to the KFA. The decompensated sagittal spinal malalignment was not related to a relapse in flexion contracture.  相似文献   

16.
背景:全膝关节置换过程中股骨假体旋转力线良好非常重要,研究显示后髁角度是确定力线的重要依据,后髁角度为股骨后髁轴与股骨手术髁上轴之间角度,MRI测量可清晰显示后髁软骨、外上髁突起及内上髁凹陷,从而保证测量数据的准确。 目的:测量保定北部地区人群中膝关节后髁角度,为临床实施全膝关节置换过程中确定股骨假体旋转力线提供影像学依据。 方法:应用核磁共振机对入选中青年人群膝关节进行扫描,取膝关节伸直中立位,扫描平面垂直于膝关节机械轴,选择T1像上最佳膝关节轴位平面,由两名观察者独自分析图像,通过Bravo viewer 6.0影像软件观察股骨内上髁存在率,画出股骨髁上轴线及后髁线并测量两条轴线之间角度,即股骨后髁角度。 结果与结论:入选人群男性股骨后髁角度为(2.73±1.28)°,女性股骨后髁角度为(2.35±1.37)°,不同性别间差异无显著性意义。提示MRI测量股骨后髁角具有较大优越性,人工全膝关节置换过程中髁上轴线变异性较小,可参照后髁角度定位安装股骨假体,避免膝关节置换后并发症发生。中国组织工程研究杂志出版内容重点:人工关节;骨植入物;脊柱;骨折;内固定;数字化骨科;组织工程全文链接:  相似文献   

17.
BackgroundRevision total knee arthroplasty commonly involves stemmed components. If the diaphysis is engaged, this technique may be problematic for mechanical alignment (MA) in cases of tibial bowing, which are not infrequent (up to 30%).The aim of this study is to compare an intra-medullary(IM) and extra-medullary(EM) alignment method. We hypothesized that IM technique and canal-filling stems may result more frequently in valgus MA. On the other hand, an EM technique could produce less valgus knees but is at risk of creating MA outliers.MethodA retrospective radiographic analysis of revision TKAs was performed. The patients were divided to either the EM or IM alignment group and compared on the overall post-operative MA. The following parameters were measured on standing, long leg x-rays: Hip-knee-Ankle angle (HKA), mechanical lateral distal femoral angle and mechanical medial proximal tibial angle (mMPTA).Results119 cases of revision TKAs were included (EM = 80, IM = 39). There was a difference between the EM and IM group for the mean mMPTA (89.94° vs 90.92°, effect size = 0.45, p = 0.013) and HKA angle (1.64° vs 0.05°, effect size = 0.52, p = 0.0064). A higher proportion of IM patients were in overall valgus alignment (16/39, 41%) vs EM group (16/80, 20%, p = 0.0134). Both techniques showed the same proportion of outliers, defined as HKA angle more than 5 degrees from neutral mechanical alignment (11/80 vs 5/39, p = 0.286).ConclusionThe extra-medullary alignment method with short cemented stems creates less valgus mechanical alignment than the intra-medullary technique with press-fit stems, without creating more MA outliers.  相似文献   