首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
ObjectivesThe aim of this study was to assess the evolution of early outcomes for 3 iterative self-expanding transcatheter aortic valves.BackgroundOver the past decade there have been rapid advancements in transcatheter aortic valve replacement (TAVR) technologies, including 3 generations of supra-annular self-expanding transcatheter systems.MethodsData from the Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry for patients undergoing TAVR with CoreValve, Evolut R, or Evolut PRO valves to treat tricuspid aortic stenosis between January 2014 and September 2017 were obtained. Patient risk and echocardiographic data are site reported. Valves analyzed included 23-, 26-, and 29-mm sizes to fit 18- to 26-mm annular diameters. Propensity score matching was performed using the Evolut PRO group as the common reference.ResultsOf 18,874 patients undergoing TAVR at 381 centers, 5,514 patients were implanted with CoreValve, 11,295 with Evolut R, and 2,065 with Evolut PRO valves. At 30 days, there were significantly fewer patients with more than mild aortic regurgitation for the unmatched (7.8% CoreValve, 5.2% Evolut R, and 2.8% Evolut PRO; p < 0.001) and matched populations (8.3% CoreValve, 5.4% Evolut R, and 3.4% Evolut PRO; p = 0.032). The mean aortic valve gradients at 30 days in the matched populations were <8 mm Hg for all 3 valves (7.3 mm Hg CoreValve, 7.5 mm Hg Evolut R, 7.2 mm Hg Evolut PRO).ConclusionsAdvancements in transcatheter valve technologies and expanding indications for TAVR have resulted in improved outcomes for patients undergoing TAVR in the United States with self-expanding, supra-annular valves. In particular, the addition of an outer pericardial tissue wrap designed to enhance sealing at the level of the aortic annulus has resulted in very low rates of significant aortic regurgitation while maintaining excellent hemodynamic status.  相似文献   

2.
BackgroundSurgical aortic valve replacement and transcatheter aortic valve replacement (TAVR) are now both used to treat aortic stenosis in patients in whom life expectancy may exceed valve durability. The choice of initial bioprosthesis should therefore consider the relative safety and efficacy of potential subsequent interventions.ObjectivesThe aim of this study was to compare TAVR in failed transcatheter aortic valves (TAVs) versus surgical aortic valves (SAVs).MethodsData were collected on 434 TAV-in-TAV and 624 TAV-in-SAV consecutive procedures performed at centers participating in the Redo-TAVR international registry. Propensity score matching was applied, and 330 matched (165:165) patients were analyzed. Principal endpoints were procedural success, procedural safety, and mortality at 30 days and 1 year.ResultsFor TAV-in-TAV versus TAV-in-SAV, procedural success was observed in 120 (72.7%) versus 103 (62.4%) patients (p = 0.045), driven by a numerically lower frequency of residual high valve gradient (p = 0.095), ectopic valve deployment (p = 0.081), coronary obstruction (p = 0.091), and conversion to open heart surgery (p = 0.082). Procedural safety was achieved in 116 (70.3%) versus 119 (72.1%) patients (p = 0.715). Mortality at 30 days was 5 (3%) after TAV-in-TAV and 7 (4.4%) after TAV-in-SAV (p = 0.570). At 1 year, mortality was 12 (11.9%) and 10 (10.2%), respectively (p = 0.633). Aortic valve area was larger (1.55 ± 0.5 cm2 vs. 1.37 ± 0.5 cm2; p = 0.040), and the mean residual gradient was lower (12.6 ± 5.2 mm Hg vs. 14.9 ± 5.2 mm Hg; p = 0.011) after TAV-in-TAV. The rate of moderate or greater residual aortic regurgitation was similar, but mild aortic regurgitation was more frequent after TAV-in-TAV (p = 0.003).ConclusionsIn propensity score–matched cohorts of TAV-in-TAV versus TAV-in-SAV patients, TAV-in-TAV was associated with higher procedural success and similar procedural safety or mortality.  相似文献   

3.
ObjectivesThe aim of this study was to evaluate the short-term safety and efficacy of transcatheter aortic valve replacement (TAVR) with the LOTUS Edge system.BackgroundThe LOTUS Edge system was commercially re-released in April 2019. The authors report the first European experience with this device.MethodsA multicenter, single-arm, retrospective registry was initiated to evaluate short-term clinical outcomes. Included cases are the first experience with this device and new implantation technique in Europe. Clinical, echocardiographic, and computed tomographic data were analyzed. Endpoints were defined according to Valve Academic Research Consortium-2 and were site reported.ResultsBetween April and November 2019, 286 consecutive patients undergoing TAVR with the LOTUS Edge system at 18 European centers were included. The mean age and Society of Thoracic Surgeons score were 81.2 ± 6.9 years and 5.2 ± 5.4%, respectively. Nearly one-half of all patients (47.9%) were considered to have complex anatomy. Thirty-day major adverse events included death (2.4% [n = 7]) and stroke (3.5% [n = 10]). After TAVR, the mean aortic valve area was 1.9 ± 0.9 cm2, and the mean transvalvular gradient was 11.9 ± 5.7 mm Hg. None or trace paravalvular leak (PVL) occurred in 84.4% and moderate PVL in 2.0%. There were no cases of severe PVL. New permanent pacemaker (PPM) implantation was required in 25.9% among all patients and 30.8% among PPM-naive patients.ConclusionsEarly experience with the LOTUS Edge system demonstrated satisfactory short-term safety and efficacy, favorable hemodynamic data, and very low rates of PVL in an anatomically complex cohort. New PPM implantation remained high. Further study will evaluate if increasing operator experience with the device and new implantation technique can reduce the incidence of PPM implantation.  相似文献   

4.
ObjectivesThe aim of this study was to define predictors of prosthesis-patient mismatch (PPM) and its impact on mortality after transcatheter aortic valve replacement (TAVR) with self-expandable valves (SEVs) in patients with small annuli.BackgroundTAVR seems to reduce the risk for PPM compared with surgical aortic valve replacement, especially in patients with small aortic annuli. Nevertheless, predictors and impact of PPM in this population have not been clarified yet.MethodsPredictors of PPM and all-cause mortality were investigated using multivariable logistic regression analysis from the cohort of the TAVI-SMALL (International Multicenter Registry to Evaluate the Performance of Self-Expandable Valves in Small Aortic Annuli) registry, which included patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 on computed tomography) treated with transcatheter SEVs: 445 patients with (n = 129) and without (n = 316) PPM were enrolled.ResultsIntra-annular valves conferred increased risk for PPM (odds ratio [OR]: 2.36; 95% confidence interval [CI]: 1.16 to 4.81), while post-dilation (OR: 0.46; 95% CI: 0.25–0.84) and valve oversizing (OR: 0.53; 95% CI: 0.28–1.00) seemed to protect against PPM occurrence. At a median follow-up of 354 days, patients with severe PPM, but not those with moderate PPM, had a higher all-cause mortality rate compared with those without PPM (log-rank p = 0.008). Multivariable Cox regression confirmed severe PPM as an independent predictor of all-cause mortality (hazard ratio: 4.27; 95% CI: 1.34 to 13.6).ConclusionsAmong patients with aortic stenosis and small aortic annuli undergoing transcatheter SEV implantation, use of intra-annular valves yielded higher risk for PPM; conversely, post-dilation and valve oversizing protected against PPM occurrence. Severe PPM was independently associated with all-cause mortality.  相似文献   

5.
ObjectivesThe aim of this study was to evaluate and compare the outcomes of transcatheter self-expandable prostheses in patients with small annuli.BackgroundTranscatheter aortic heart valves appear to have better performance than surgical valves in terms of prosthesis-patient mismatch, especially in patients with aortic stenosis with small aortic annuli.MethodsTAVI-SMALL (International Multicenter Registry to Evaluate the Performance of Self-Expandable Valves in Small Aortic Annuli) is a retrospective registry of patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 on computed tomography) treated with transcatheter self-expandable valves (n = 859; Evolut R, n = 397; Evolut PRO, n = 84; ACURATE, n = 201; Portico, n = 177). Primary endpoints were post-procedural mean aortic gradient, indexed effective orifice area, and rate of severe prosthesis-patient mismatch.ResultsPre-discharge gradients were consistently low in every group, with a slight benefit with the Evolut R (8.1 mm Hg; 95% confidence interval [CI]: 7.7 to 8.5 mm Hg) and Evolut PRO (6.9 mm Hg; 95% CI: 6.3 to 7.6 mm Hg) compared with the ACURATE (9.6 mm Hg; 95% CI: 8.9 to 10.2 mm Hg) and Portico (8.9 mm Hg; 95% CI: 8.2 to 9.6 mm Hg) groups (p < 0.001). Mean indexed effective orifice area was 1.04 cm2/m2 (95% CI: 1.01 to 1.08 cm2/m2) with a trend toward lower values with the Portico. No significant differences were reported in terms of severe prosthesis-patient mismatch (overall rate 9.4%; p = 0.134), permanent pacemaker implantation (15.6%), and periprocedural and 1-year adverse events. Pre-discharge more than mild paravalvular leaks were significantly more common with the Portico (19.2%) and less common with the Evolut PRO (3.6%) compared with the Evolut R (11.8%) and ACURATE (9%) groups.ConclusionsTranscatheter self-expandable valves showed optimal clinical and echocardiographic results in patients with small aortic annuli, although supra-annular functioning transcatheter heart valves seemed to slightly outperform intra-annular functioning ones. The role of transcatheter aortic valve replacement with self-expandable valves for the treatment of aortic stenosis in patients with small annuli needs to be confirmed in larger trials.  相似文献   

6.
ObjectivesThis study sought to compare outcomes in patients with bicuspid versus tricuspid anatomy undergoing transcatheter aortic valve replacement (TAVR).BackgroundTAVR has shown excellent safety and efficacy in patients with tricuspid aortic valve stenosis, but limited data are available on the use of self-expanding valves in patients with bicuspid valves.MethodsThe Society of Thoracic Surgeons/American College of Cardiology TVT Registry was used to analyze patients who underwent TAVR with the Evolut R or Evolut PRO valves. Clinical and echocardiographic outcomes were analyzed through 1-year follow-up.ResultsBetween July 2015 and September 2018 a total of 932 patients with bicuspid aortic valve stenosis underwent elective TAVR with the self-expanding Evolut R or Evolut PRO valve. These patients were compared with a group of 26,154 patients with tricuspid aortic stenosis who underwent TAVR during that same time period. At baseline, patients with bicuspid valves were younger, had fewer cardiac comorbidities, and had lower Society of Thoracic Surgeons Predicted Risk of Mortality scores (5.3 ± 4.2% vs. 6.9 ± 4.8%; p < 0.001). To account for these differences, propensity matching was performed, which resulted in 929 matched pairs. Within these match groups, the rates of all-cause mortality at 30 days (2.6% vs. 1.7%; p = 0.18) and 1 year (10.4% vs. 12.1%; p = 0.63), as well the rate of stroke at 30 days (3.4% vs. 2.7%; p = 0.41) and 1 year (3.9% vs. 4.4%; p = 0.93), were comparable.ConclusionsAll-cause mortality, stroke, and valve hemodynamics did not differ at 30 days or 1 year between patient groups. In patients at increased surgical risk, TAVR for bicuspid aortic valve stenosis indicates acceptable safety outcomes with low complications rates.  相似文献   

7.
ObjectivesThe aim of this study was to compare the incidence and prognostic significance of prosthesis-patient mismatch (PPM) after transcatheter aortic valve replacement (TAVR) according to racial groups.BackgroundPPM after TAVR may be of more concern in Asian populations considering their relatively small annular and valve sizes compared with Western populations.MethodsTP-TAVR (Transpacific TAVR Registry) was an international multicenter cohort study of patients with severe aortic stenosis who underwent TAVR in the United States and South Korea from January 2015 to November 2019. PPM was defined as moderate (0.65-0.85 cm2/m2) or severe (<0.65 cm2/m2) at the indexed effective orifice area. The primary outcome was a composite of death, stroke, or rehospitalization at 1 year.ResultsAmong 1,101 eligible patients (533 Asian and 569 non-Asian), the incidence of PPM was significantly lower in the Asian population (33.6%; moderate, 26.5%; severe, 7.1%) than in the non-Asian population (54.5%; moderate, 29.8%; severe, 24.7%). The 1-year rate of the primary outcome was similar between the PPM and non-PPM groups (27.5% vs 28.1%; P = 0.69); this pattern was consistent between Asian (25.4% vs 25.2%; P = 0.31) and non-Asian (28.7% vs 32.1%; P = 0.97) patients. After multivariable adjustment, the risk for the primary outcome did not significantly differ between the PPM and non-PPM groups in the overall population (HR: 0.95; 95% CI: 0.74-1.21), in Asian patients (HR: 1.07; 95% CI: 0.74-1.55), and in non-Asian patients (HR: 0.86; 95% CI: 0.63-1.19).ConclusionsIn this study of patients with severe aortic stenosis who underwent TAVR, the incidence of PPM was significantly lower in Asian patients than in non-Asian patients. The 1-year risk for the primary composite outcome was similar between the PPM and non-PPM groups regardless of racial group. (Transpacific TAVR Registry [TP-TAVR]; NCT03826264)  相似文献   

8.
ObjectivesThe aim of this study was to compare 1-year outcomes after transcatheter aortic valve replacement (TAVR) in low surgical risk patients with bicuspid aortic stenosis to patients with tricuspid aortic stenosis.BackgroundThe pivotal TAVR trials excluded patients with bicuspid aortic valves. The Low Risk Bicuspid Study 30-day primary endpoint of death or disabling stroke was 1.3%.MethodsThe Low Risk Bicuspid Study is a prospective, single-arm, TAVR trial that enrolled patients from 25 U.S. sites. A screening committee confirmed bicuspid anatomy and valve classification on computed tomography using the Sievers classification. Valve sizing was by annular measurements. An independent clinical events committee adjudicated all serious adverse events, and an independent core laboratory assessed all echocardiograms. The 150 patients from the Low Risk Bicuspid Study were propensity matched to the TAVR patients in the randomized Evolut Low Risk Trial using the 1:1 5- to-1-digit greedy method, resulting in 145 pairs.ResultsAll-cause mortality or disabling stroke at 1 year was 1.4% in the bicuspid and 2.8% in the tricuspid group (P = 0.413). A pacemaker was implanted in 16.6% of bicuspid and 17.9% of tricuspid patients (P = 0.741). The effective orifice area was similar between groups at 1 year (2.2 ± 0.7 cm2 vs 2.3 ± 0.6 cm2, P = 0.677) as was the mean gradient (8.7 ± 3.9 mm Hg vs 8.5 ± 3.1 mm Hg, P = 0.754). Fewer patients in the bicuspid group had mild or worse paravalvular leak (21.3% vs 42.6%, P < 0.001).ConclusionsThere were no significant differences in clinical or forward flow hemodynamic outcomes between the propensity-matched groups at 1 year.  相似文献   

9.
ObjectivesThis study sought to evaluate the 30-day and 1-year safety and performance of the Hydra transcatheter aortic valve (THV) in the treatment of symptomatic severe aortic stenosis in patients at high or extreme surgical risk.BackgroundThe Hydra THV is a novel repositionable self-expanding system with supra-annular bovine pericardial leaflets.MethodsThe Hydra CE study was a premarket, prospective, multicenter, single-arm study conducted across 18 study centers in Europe and Asia-Pacific countries. The primary endpoint was all-cause mortality at 30 days. All endpoints were adjudicated by an independent clinical events committee.ResultsA total of 157 patients (79.2 ± 7.1 years of age, 58.6% female; Society of Thoracic Surgeons score 4.7 ± 3.4%) were enrolled. Successful implantation was achieved in 94.3% cases. At 30 days, there were 11 (7.0%) deaths, including 9 (5.7%) cardiovascular deaths, of which 5 (3.2%) were device related. At 1 year, there were 23 (14.6%) deaths, including 13 (8.3%) cardiovascular deaths. At 30 days, there were significant improvement of effective orifice area (from 0.7 ± 0.2 cm2 to 1.9 ± 0.6 cm2) and mean aortic valve gradient (from 49.5 ± 18.5 mm Hg to 8.1 ± 3.7 mm Hg), which were sustained up to 1 year. Moderate or severe paravalvular leak was observed in 6.3% of patients at 30 days and 6.9% of patients at 1 year. The rate of new permanent pacemaker implantation was 11.7% at 30 days and 12.4% at 1 year.ConclusionsThe Hydra CE study demonstrated that transcatheter aortic valve replacement with Hydra THV offered favorable efficacy at 1 year, providing large effective orifice area and low transvalvular gradient as well as acceptable complication rates with regard to new permanent pacemaker and paravalvular leak. (A Clinical Evaluation of the HYDRA Self Expanding Transcatheter Aortic Valve; NCT02434263)  相似文献   

10.
ObjectivesThe aim of this study was to evaluate device success of transcatheter aortic valve replacement (TAVR) using new-generation balloon-expandable prostheses with or without balloon aortic valvuloplasty (BAV).BackgroundRandomized studies are lacking comparing TAVR without BAV against the conventional technique of TAVR with BAV.MethodsDIRECTAVI (Direct Transcatheter Aortic Valve Implantation) was an open-label noninferiority study that randomized patients undergoing TAVR using the Edwards SAPIEN 3 valve with or without prior balloon valvuloplasty. The primary endpoint was the device success rate according to Valve Academic Research Consortium-2 criteria, which was evaluated using a 7% noninferiority margin. The secondary endpoint included procedural and 30-day adverse events.ResultsDevice success was recorded for 184 of 236 included patients (78.0%). The rate of device success in the direct implantation group (n = 97 [80.2%]) was noninferior to that in the BAV group (n = 87 [75.7%]) (mean difference 4.5%; 95% confidence interval: −4.4% to 13.4%; p = 0.02 for noninferiority). No severe prosthesis-patient mismatch or severe aortic regurgitation occurred in any group. In the direct implantation group, 7 patients (5.8%) required BAV to cross the valve. Adverse events were related mainly to pacemaker implantation (20.9% in the BAV group vs. 19.0% in the direct implantation group; p = 0.70). No significant difference was found between the 2 strategies in duration of procedure, contrast volume, radiation exposure, or rate of post-dilatation.ConclusionsDirect TAVR without prior BAV was noninferior to the conventional strategy using BAV with new-generation balloon-expandable valves, but without procedural simplification. BAV was needed to cross the valve in a few patients, suggesting a need for upstream selection on the basis of patient anatomy. (TAVI Without Balloon Predilatation [of the Aortic Valve] SAPIEN 3 [DIRECTAVI]; NCT02729519)  相似文献   

11.
ObjectivesThis study sought to predict whether different methods of calculating the implantation depth (ID) influence clinical and hemodynamic outcome reporting in patients undergoing transcatheter aortic valve replacement (TAVR) with a self-expandable device.BackgroundDifferent approaches exist to calculate the ID, which may influence uniform and reliable reporting because the updated Valve Academic Research Consortium (VARC-2) criteria do not provide specific instructions.MethodsThe clinical and hemodynamic outcomes of 258 patients undergoing TAVR with a third-generation self-expandable device were analyzed with regard to the method used to assess the ID as follows: arithmetic mean, the arithmetic mean of the measured distances from the noncoronary cusp and the left coronary cusp to the distal prosthesis end; noncoronary cusp distance, the distance from the noncoronary cusp to the distal prosthesis end; and deepest edge, the deepest edge of the distal prosthesis end.ResultsRegardless of the measurement method, the optimal ID (OID) was reached in <30% (arithmetic mean, 25.4%; noncoronary cusp distance, 28.4%; deepest edge, 20.5%; p = 0.008). The deepest edge method is the most stringent to differentiate the relevant outcome parameters, such as the need for permanent pacemaker implantation (OID 3.7% vs. no OID 14.6%; p = 0.033). The hemodynamic outcome (i.e., mean pressure gradient reduction after TAVR: OID 7.4 ± 3.4 mm Hg vs. no OID 8.3 ± 4.0 mm Hg; p = 0.093) was not affected.ConclusionsThe OID was reached in <30% of TAVR procedures. The various methods applied for ID calculation significantly influence the outcome reporting and do not allow a uniform perception of the ID. (Multi Modal Cardiac Imaging Prior Transcatheter Aortic Valve Implantation; NCT01805739)  相似文献   

12.
BackgroundIt is unknown whether the sex difference whereby female transcatheter aortic valve replacement (TAVR) candidates had a lower risk profile, a higher incidence of in-hospital complications, but more favorable short- and long-term survival observed in tricuspid cohorts undergoing TAVR would persist in patients with bicuspid aortic valves (BAVs).ObjectivesThe aim of this study was to reexamine the impact of sex on outcomes following TAVR in patients with BAVs.MethodsIn this single-center study, patients with BAVs undergoing TAVR for severe aortic stenosis from 2012 to 2021 were retrospectively included. Baseline characteristics, aortic root anatomy, and in-hospital and 1-year valve hemodynamic status and survival were compared between sexes.ResultsA total of 510 patients with BAVs were included. At baseline, women presented with fewer comorbidities. Men had a greater proportion of Sievers type 1 BAV, higher calcium volumes (549.2 ± 408.4 mm3 vs 920.8 ± 654.3 mm3; P < 0.001), and larger aortic root structures. Women experienced more vascular complications (12.9% vs 4.9%; P = 0.002) and bleeding (11.1% vs 5.3%; P = 0.019) and higher residual gradients (16.9 ± 7.7 mm Hg vs 13.2 ± 6.4 mm Hg; P < 0.001), while men were more likely to undergo second valve implantations during index TAVR (6.3% vs 15.9%; P = 0.001). Death at 1 year was not significantly different between sexes (HR: 1.15; 95% CI: 0.56-2.35; P = 0.70). Bleeding (adjusted HR: 4.62; 95% CI: 1.51-14.12; P = 0.007) was the single independent predictor of 1-year death for women.ConclusionsIn patients with BAVs undergoing TAVR, women presented with fewer comorbidities, while men had a greater proportion of type 1 BAV, more calcification, and larger aortic roots. In-hospital outcomes favored men, with fewer complications except for the need for second valve implantation, but 1-year survival was comparable between sexes.  相似文献   

13.
ObjectivesThe aim of this study was to compare 5-year cardiovascular, renal, and bioprosthetic valve durability outcomes in patients with severe aortic stenosis (AS) and chronic kidney disease (CKD) undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR).BackgroundPatients with severe AS and CKD undergoing TAVR or SAVR are a challenging, understudied clinical subset.MethodsIntermediate-risk patients with moderate to severe CKD (estimated glomerular filtration rate <60 mL/min/m2) from the PARTNER (Placement of Aortic Transcatheter Valve) 2A trial (patients randomly assigned to SAPIEN XT TAVR or SAVR) and SAPIEN 3 Intermediate Risk Registry were pooled. The composite primary outcome of death, stroke, rehospitalization, and new hemodialysis was evaluated using Cox regression analysis. Patients with and without perioperative acute kidney injury (AKI) were followed through 5 years. A core laboratory–adjudicated analysis of structural valve deterioration and bioprosthetic valve failure was also performed.ResultsThe study population included 1,045 TAVR patients (512 SAPIEN XT, 533 SAPIEN 3) and 479 SAVR patients. At 5 years, SAVR was better than SAPIEN XT TAVR (52.8% vs 68.0%; P = 0.04) but similar to SAPIEN 3 TAVR (52.8% vs 58.7%; P = 0.89). Perioperative AKI was more common after SAVR than TAVR (26.3% vs 10.3%; P < 0.001) and was independently associated with long-term outcomes. Compared with SAVR, bioprosthetic valve failure and stage 2 or 3 structural valve deterioration were significantly greater for SAPIEN XT TAVR (P < 0.05) but not for SAPIEN 3 TAVR.ConclusionsIn intermediate-risk patients with AS and CKD, SAPIEN 3 TAVR and SAVR were associated with a similar risk for the primary endpoint at 5 years. AKI was more common after SAVR than TAVR, and SAPIEN 3 valve durability was comparable with that of surgical bioprostheses.  相似文献   

14.
BackgroundTranscatheter aortic valve replacement (TAVR) is generally performed without control over the alignment of the bioprosthesis to the native aortic valve (AV) commissures. Data on the impact of commissural misalignment (CMA) on the clinical and hemodynamic outcome after TAVR are scarce.ObjectivesThe aim of this study was to investigate the impact of commissural misalignment (CMA) on the clinical and hemodynamic outcome in patients with severe tricuspid aortic stenosis undergoing TAVR using the balloon-expandable (BE) SAPIEN 3 valve (Edwards LifeSciences).MethodsClinical data of consecutive patients who underwent BE TAVR at Cedars-Sinai Medical Center (Los Angeles, California, USA) enrolled in the RESOLVE (Assessment of TRanscathetER and Surgical Aortic BiOprosthetic Valve Thrombosis and Its TrEatment With Anticoagulation) registry were retrospectively analyzed to evaluate CMA, which was defined as a neocommissure position >30° compared with native commissures on computed tomography.ResultsA total of 324 patients (36.6% female, median Society of Thoracic Surgeons score of 3.9%) were included in the analysis. CMA was present in 171 individuals (52.8%). At 30 days, rates of aortic regurgitation greater than mild (5.6%) and a residual AV gradient ≥20 mm Hg (7.4%) were not different between CMA and non-CMA patients. Commissural orientation was independently associated with a relative AV mean gradient increase >50% from discharge to 30 days (per increase of 10° misalignment; OR: 1.3; 95% CI: 1.0-1.4; P = 0.01). The long-term composite outcome of death or stroke was not different between groups (log-rank P = 0.29).ConclusionsIn patients with severe tricuspid aortic stenosis who undergo SAPIEN 3 TAVR, the neocommissures align randomly. Our data demonstrate that commissural alignment may impact device performance and clinical outcomes in patients undergoing BE TAVR. (Assessment of TRanscathetEr and Surgical Aortic BiOprosthetic VaLVve Dysfunction with Multimodality Imaging and Its TrEatment with Anticoagulation [RESOLVE]; NCT02318342)  相似文献   

15.
ObjectivesThis study sought to better understand out-of-hospital 30-day mortality following transfemoral transcatheter aortic valve replacement (TAVR) and identify factors associated with poor outcomes.BackgroundDespite improvements in outcomes with TAVR for severe aortic stenosis, out-of-hospital 30-day mortality has not been evaluated.MethodsThis study examined patients in the Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry undergoing TAVR for severe aortic stenosis from January 2015 to March 2018. Primary and secondary endpoints were 30-day out-of-hospital all-cause mortality and out-of-hospital cardiovascular mortality, respectively. Logistic regression models were used to assess association between pre-specified factors and endpoints.ResultsA total of 106,749 patients underwent TAVR and were eligible for analysis. Transfemoral TAVR was performed in 92.3% of patients. A total of 2,137 (2.2%) transfemoral patients died within 30 days of the procedure, and 623 (29%) patients of these patients experienced out-of-hospital 30-day mortality. Cardiovascular and pulmonary etiologies accounted for the majority of observed mortality. Multivariable regression analysis identified older age, gender, lower body surface area, lower left ventricular ejection fraction, lower hemoglobin, atrial fibrillation or flutter, severe lung disease, home oxygen use, lack of moderate-to-severe aortic insufficiency, urgent TAVR, lower Kansas City Cardiomyopathy Questionnaire score, longer hospital length of stay, and in-hospital complications as being independently associated with the primary endpoint. New onset or pre-existent atrial fibrillation or flutter was also independently associated with 30-day out-of-hospital cardiovascular mortality in the transfemoral population.ConclusionsWe identified 30-day all-cause mortality rate for TAVR of 2.2%. Approximately one-third of patients experienced out-of-hospital mortality at 30 days. Several factors were identified as being independently associated with 30-day out-of-hospital all-cause and cardiovascular mortality. Further work is needed to understand how best to improve out-of-hospital mortality following TAVR.  相似文献   

16.
ObjectivesThis study aimed to compare incidence and impact of measured prosthesis-patient mismatch (PPMM) versus predicted PPM (PPMP) after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR).BackgroundTAVR studies have used measured effective orifice area indexed (EOAi) to body surface area (BSA) to define PPM, but most SAVR series have used predicted EOAi. This difference may contribute to discrepancies in incidence and outcomes of PPM between series.MethodsThe study analyzed SAVR patients from the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and TAVR patients from the PARTNER 2 SAPIEN 3 Intermediate Risk registry. PPM was classified as moderate if EOAi ≤0.85 cm2/m2 (≤0.70 if obese: body mass index ≥30 kg/m2) and severe if EOAi ≤0.65 cm2/m2 (≤0.55 if obese). PPMM was determined by the core lab–measured EOAi on 30-day echocardiogram. PPMP was determined by 2 methods: 1) using normal EOA reference values previously reported for each valve model and size (PPMP1; n = 929 SAVR, 1,069 TAVR) indexed to BSA; and 2) using normal reference EOA predicted from aortic annulus size measured by computed tomography (PPMP2; n = 864 TAVR only) indexed to BSA. Primary endpoint was the composite of 5-year all-cause death and rehospitalization.ResultsThe incidence of moderate and severe PPMP was much lower than PPMM in both SAVR (PPMP1: 28.4% and 1.2% vs. PPMM: 31.0% and 23.6%) and TAVR (PPMP1: 21.0% and 0.1% and PPMP2: 17.0% and 0% vs. PPMM: 27.9% and 5.7%). The incidence of severe PPMM and severe PPMP1 was lower in TAVR versus SAVR (P < 0.001). The presence of PPM by any method was associated with higher transprosthetic gradient. Severe PPMP1 was independently associated with events in SAVR after adjustment for sex and Society of Thoracic Surgeons score (hazard ratio: 3.18;95% CI: 1.69-5.96; P < 0.001), whereas no association was observed between PPM by any method and outcomes in TAVR.ConclusionsEOAi measured by echocardiography results in a higher incidence of PPM following SAVR or TAVR than PPM based on predicted EOAi. Severe PPMP is rare (<1.5%), but is associated with increased all-cause death and rehospitalization after SAVR, whereas it is absent following TAVR.  相似文献   

17.
BackgroundThe 30-day rate of stroke after transcatheter aortic valve replacement (TAVR) has been suggested as a hospital quality metric. Thirty-day stroke rates for nonsurgical, high, and moderate-risk TAVR trials were 3.4% to 6.1%, whereas those in the national Transcatheter Valve Therapy (TVT) Registry for the same patient population were much lower. Hospital comprehensive stroke center (CSC) is the highest designation for integrated acute stroke recognition, management, and care.ObjectivesUsing Michigan TVT data, we assessed whether in-hospital post-TAVR stroke rates varied between CSC and non-CSC institutions.MethodsTVT data submitted from the 22 Michigan Transcatheter Aortic Valve Replacement Collaborative participating institutions between January 1, 2016, and June 30, 2019, were included (N = 6,231). Bayesian hierarchical regression models accounting for patient clinical characteristics and hospital clustering were fitted to assess the association between hospital CSC accreditation and in-hospital post-TAVR stroke. Adjusted ORs and 95% credible intervals were estimated. The University of Michigan Institutional Review Board has waived the need for the approval of studies based on the data collected by the Blue Cross Blue Shield of Michigan Cardiovascular Consortium registry.ResultsThere were 3,882 (62.3%) patients at 9 CSC sites and 2,349 (37.7%) patients at 13 non-CSC sites. CSC sites had significantly higher rates of in-hospital post-TAVR stroke (CSC: 2.65% vs non-CSC: 1.15%; P < 0.001). After adjustment, patients who underwent TAVR at a CSC hospital had a significantly higher risk of in-hospital stroke (adjusted OR: 2.21; 95% CI: 1.03-4.62). However, CSC designation was not significantly associated with other important post-TAVR clinical outcomes including 30-day mortality.ConclusionsReported Michigan Transcatheter Aortic Valve Replacement Collaborative TVT stroke rates were significantly higher at sites with Joint Hospital Commission stroke designation status; however, other reported important clinical outcomes did not differ significantly based on this designation. CSC designation is a possible factor in stroke rate detection differences between TAVR institutions and might be a factor in the observed differences in stroke rates between TAVR trials and those reported in TVT. In addition, these data suggest that comparison between hospitals based on post-TAVR stroke rates is potentially problematic.  相似文献   

18.
BackgroundTranscatheter aortic valve replacement (TAVR) for degenerated surgical bioprosthetic aortic valves is associated with favorable early outcomes. However, little is known about the durability and longer-term outcomes associated with this therapy.ObjectivesThe aim of this study was to examine late outcomes after valve-in-valve TAVR.MethodsPatients with symptomatic degeneration of surgical aortic bioprostheses at high risk (≥50% major morbidity or mortality) for reoperative surgery were prospectively enrolled in the multicenter PARTNER (Placement of Aortic Transcatheter Valves) 2 valve-in-valve and continued access registries. Three-year clinical and echocardiographic follow-up was obtained.ResultsValve-in-valve procedures were performed in 365 patients. The mean age was 78.9 ± 10.2 years, and the mean Society of Thoracic Surgeons score was 9.1 ± 4.7%. At 3 years, the overall Kaplan-Meier estimate of all-cause mortality was 32.7%. Aortic valve re-replacement was required in 1.9%. Mean transaortic gradient was 35.0 mm Hg at baseline, decreasing to 17.8 mm Hg at 30-day follow-up and 16.6 mm Hg at 3-year follow-up. Baseline effective orifice area was 0.93 cm2, increasing to 1.13 and 1.15 cm2 at 30 days and 3 years, respectively. Moderate to severe aortic regurgitation was reduced from 45.1% at pre-TAVR baseline to 2.5% at 3 years. Importantly, moderate or severe mitral and tricuspid regurgitation also decreased (33.7% vs. 8.6% [p < 0.0001] and 29.7% vs. 18.8% [p = 0.002], respectively). Baseline left ventricular ejection fraction was 50.7%, increasing to 54.7% at 3 years (p < 0.0001), while left ventricular mass index was 136.4 g/m2, decreasing to 109.1 g/m2 at 3 years (p < 0.0001). New York Heart Association functional class improved, with 90.4% in class III or IV at baseline and 14.1% at 3 years (p < 0.0001), and Kansas City Cardiomyopathy Questionnaire overall score increased (43.1 to 73.1; p < 0.0001).ConclusionsAt 3-year follow-up, TAVR for bioprosthetic aortic valve failure was associated with favorable survival, sustained improved hemodynamic status, and excellent functional and quality-of-life outcomes. (The PARTNER II Trial: Placement of Aortic Transcatheter Valves II - PARTNER II - Nested Registry 3/Valve-in-Valve [PII NR3/ViV]; NCT03225001)  相似文献   

19.
BackgroundSelf-expanding transcatheter heart valves (THVs) are associated with better echocardiographic hemodynamic performance than balloon-expandable THVs and are considered preferable in patients with small annuli.ObjectivesThis study sought to compare 5-year outcomes between self-expanding vs balloon-expandable THVs in severe aortic stenosis (AS) patients with small annuli.MethodsConsecutive severe AS patients with an aortic valve annulus area <430 mm2 who underwent transcatheter aortic valve replacement (TAVR) with either the CoreValve Evolut (Medtronic) or SAPIEN (Edwards Lifesciences) THV between 2012 and 2021 were enrolled from the Bern TAVI registry. A 1:1 propensity-matched analysis was performed to account for baseline differences between groups.ResultsA total of 723 patients were included, and propensity score matching resulted in 171 pairs. Technical success was achieved in over 85% of both groups with no significant difference. Self-expanding THVs were associated with a lower transvalvular gradient (8.0 ± 4.8 mm Hg vs 12.5 ± 4.5 mm Hg; P < 0.001), a larger effective orifice area (1.81 ± 0.46 cm2 vs 1.49 ± 0.42 cm2; P < 0.001), and a lower incidence of prosthesis-patient mismatch (19.7% vs 51.8%; P < 0.001) than balloon-expandable THVs. At 5 years, there were no significant differences in mortality (50.4% vs 39.6%; P = 0.269) between groups. Disabling stroke occurred more frequently in patients with a self-expanding THV than those with a balloon-expandable THV (6.6% vs 0.6%; P = 0.030). Similar results were obtained using inverse probability of treatment weighting in the Bern TAVI registry and the nationwide Swiss TAVI registry.ConclusionsThe echocardiographic hemodynamic advantage of self-expanding THVs was not associated with better clinical outcomes compared with balloon-expandable THVs up to 5 years in patients with small annuli. (Swiss TAVI Registry; NCT01368250)  相似文献   

20.
BackgroundIn patients with end-stage renal disease (ESRD), surgical aortic valve replacement is associated with higher early and late mortality, and adverse outcomes compared with patients without renal disease. Transcatheter aortic valve replacement (TAVR) offers another alternative, but there are limited reported outcomes.ObjectivesThe purpose of this study was to determine the outcomes of TAVR in patients with ESRD.MethodsAmong the first 72,631 patients with severe aortic stenosis (AS) treated with TAVR enrolled in the Society of Thoracic Surgeons (STS)/American College of Cardiology (ACC) TVT (Transcatheter Valve Therapies) registry, 3,053 (4.2%) patients had ESRD and were compared with patients who were not on dialysis for demographics, risk factors, and outcomes.ResultsCompared with the nondialysis patients, ESRD patients were younger (76 years vs. 83 years; p < 0.01) and had higher rates of comorbidities leading to a higher STS predicted risk of mortality (median 13.5% vs. 6.2%; p < 0.01). ESRD patients had a higher in-hospital mortality (5.1% vs. 3.4%; p < 0.01), although the observed to expected ratio was lower (0.32 vs. 0.44; p < 0.01). ESRD patients also had a similar rate of major vascular complications (4.5% vs. 4.6%; p = 0.86), but a higher rate of major bleeding (1.4% vs. 1.0%; p = 0.03). The 1-year mortality was significantly higher in dialysis patients (36.8% vs. 18.7%; p < 0.01).ConclusionsPatients undergoing TAVR with ESRD are at higher risk and had higher in-hospital mortality and bleeding, but similar vascular complications, when compared with those who are not dialysis dependent. The 1-year survival raises concerns regarding diminished benefit in this population. TAVR should be used judiciously after full discussion of the risk-benefit ratio in patients on dialysis.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号