1.
BackgroundIn low surgical risk patients with symptomatic severe aortic stenosis, the PARTNER 3 (Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis) trial demonstrated superiority of transcatheter aortic valve replacement (TAVR) versus surgery for the primary endpoint of death, stroke, or re-hospitalization at 1 year.ObjectivesThis study determined both clinical and echocardiographic outcomes between 1 and 2 years in the PARTNER 3 trial.MethodsThis study randomly assigned 1,000 patients (1:1) to transfemoral TAVR with the SAPIEN 3 valve versus surgery (mean Society of Thoracic Surgeons score: 1.9%; mean age: 73 years) with clinical and echocardiography follow-up at 30 days and at 1 and 2 years. This study assessed 2-year rates of the primary endpoint and several secondary endpoints (clinical, echocardiography, and quality-of-life measures) in this as-treated analysis.ResultsPrimary endpoint follow-up at 2 years was available in 96.5% of patients. The 2-year primary endpoint was significantly reduced after TAVR versus surgery (11.5% vs. 17.4%; hazard ratio: 0.63; 95% confidence interval: 0.45 to 0.88; p = 0.007). Differences in death and stroke favoring TAVR at 1 year were not statistically significant at 2 years (death: TAVR 2.4% vs. surgery 3.2%; p = 0.47; stroke: TAVR 2.4% vs. surgery 3.6%; p = 0.28). Valve thrombosis at 2 years was increased after TAVR (2.6%; 13 events) compared with surgery (0.7%; 3 events; p = 0.02). Disease-specific health status continued to be better after TAVR versus surgery through 2 years. Echocardiographic findings, including hemodynamic valve deterioration and bioprosthetic valve failure, were similar for TAVR and surgery at 2 years.ConclusionsAt 2 years, the primary endpoint remained significantly lower with TAVR versus surgery, but initial differences in death and stroke favoring TAVR were diminished and patients who underwent TAVR had increased valve thrombosis. (Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis [PARTNER 3]; NCT02675114)  相似文献   

2.
BackgroundThe extent of extravalvular cardiac damage is associated with increased risk of adverse events among patients with severe aortic stenosis undergoing aortic valve replacement (AVR).ObjectivesThe goal was to describe the association of cardiac damage on health status before and after AVR.MethodsPatients from the PARTNER (Placement of Aortic Transcatheter Valves) 2 and 3 trials were pooled and classified by echocardiographic cardiac damage stage at baseline and 1 year as previously described (stage 0-4). We examined the association between baseline cardiac damage and 1-year health status (assessed by the Kansas City Cardiomyopathy Questionnaire Overall Score [KCCQ-OS]).ResultsAmong 1,974 patients (794 surgical AVR, 1,180 transcatheter AVR), the extent of cardiac damage at baseline was associated with lower KCCQ scores both at baseline and at 1 year after AVR (P < 0.0001) and with increased rates of a poor outcome (death, KCCQ-OS <60, or a decrease in KCCQ-OS of ≥10 points) at 1 year (stages 0-4: 10.6% vs 19.6% vs 29.0% vs 44.7% vs 39.8%; P < 0.0001). In a multivariable model, each 1-stage increase in baseline cardiac damage was associated with a 24% increase in the odds of a poor outcome (95% CI: 9%-41%; P = 0.001). Change in stage of cardiac damage at 1 year after AVR was associated with the extent of improvement in KCCQ-OS over the same period (mean change in 1-year KCCQ-OS: improvement of ≥1 stage +26.8 [95% CI: 24.2-29.4] vs no change +21.4 [95% CI: 20.0-22.7] vs deterioration of ≥1 stage +17.5 [95% CI: 15.4-19.5]; P < 0.0001).ConclusionsThe extent of cardiac damage before AVR has an important impact on health status outcomes, both cross-sectionally and after AVR. (PARTNER II Trial: Placement of AoRTic TraNscathetER Valves II - XT Intermediate and High Risk (PII A), NCT01314313; The PARTNER II Trial: Placement of AoRTic TraNscathetER Valves - PII B [PARTNERII B], NCT02184442; PARTNER 3 Trial: Safety and Effectiveness of the SAPIEN 3 Transcatheter Heart Valve in Low Risk Patients With Aortic Stenosis [P3], NCT02675114)  相似文献   

3.
ObjectivesThe aim of this study was to report the outcomes of valve-in-valve (ViV) transcatheter aortic valve replacement (TAVR) at 5 years.BackgroundTAVR for degenerated surgical bioprostheses in patients at high risk for reoperative surgery is an important treatment option that may delay or obviate the need for surgical intervention; however, long-term outcomes of this procedure are unknown.MethodsThe PARTNER (Placement of Aortic Transcatheter Valves) 2 ViV and continued access registries prospectively enrolled patients with failed surgical bioprostheses at high risk for reoperation. Five-year clinical and echocardiographic follow-up data were obtained in 95.9% of patients.ResultsIn 365 (96 registry and 269 continued access) patients, the mean age was 78.9 ± 10.2 years, the mean Society of Thoracic Surgeons predicted risk of surgical mortality score was 9.1 ± 4.7%, and New York Heart Association functional class was III or IV in 90.4%. At 5 years, the Kaplan-Meier rates of all-cause mortality and any stroke were 50.6% and 10.5%, respectively. Using Valve Academic Research Consortium 3 definitions, the incidence of structural valve deterioration, related hemodynamic valve deterioration, or bioprosthetic valve failure at 5 years was 6.6%. Aortic valve re-replacement was performed in 6.3% (n = 14), the majority of which was due to stenosis (n = 6) and combined aortic insufficiency/paravalvular regurgitation (n = 3). The mean gradient, Doppler velocity index, paravalvular regurgitation, and quality of life measured by Kansas City Cardiomyopathy Questionnaire scores in survivors remained stable from 30 days postprocedure through 5 years.ConclusionsAt the 5-year follow-up, TAVR for bioprosthetic aortic valve failure in high surgical risk patients was associated with sustained improvement in clinical and echocardiographic outcomes.  相似文献   

4.
ObjectivesThe aim of this study was to assess the evolution of early outcomes for 3 iterative self-expanding transcatheter aortic valves.BackgroundOver the past decade there have been rapid advancements in transcatheter aortic valve replacement (TAVR) technologies, including 3 generations of supra-annular self-expanding transcatheter systems.MethodsData from the Society of Thoracic Surgeons/American College of Cardiology TVT (Transcatheter Valve Therapy) Registry for patients undergoing TAVR with CoreValve, Evolut R, or Evolut PRO valves to treat tricuspid aortic stenosis between January 2014 and September 2017 were obtained. Patient risk and echocardiographic data are site reported. Valves analyzed included 23-, 26-, and 29-mm sizes to fit 18- to 26-mm annular diameters. Propensity score matching was performed using the Evolut PRO group as the common reference.ResultsOf 18,874 patients undergoing TAVR at 381 centers, 5,514 patients were implanted with CoreValve, 11,295 with Evolut R, and 2,065 with Evolut PRO valves. At 30 days, there were significantly fewer patients with more than mild aortic regurgitation for the unmatched (7.8% CoreValve, 5.2% Evolut R, and 2.8% Evolut PRO; p < 0.001) and matched populations (8.3% CoreValve, 5.4% Evolut R, and 3.4% Evolut PRO; p = 0.032). The mean aortic valve gradients at 30 days in the matched populations were <8 mm Hg for all 3 valves (7.3 mm Hg CoreValve, 7.5 mm Hg Evolut R, 7.2 mm Hg Evolut PRO).ConclusionsAdvancements in transcatheter valve technologies and expanding indications for TAVR have resulted in improved outcomes for patients undergoing TAVR in the United States with self-expanding, supra-annular valves. In particular, the addition of an outer pericardial tissue wrap designed to enhance sealing at the level of the aortic annulus has resulted in very low rates of significant aortic regurgitation while maintaining excellent hemodynamic status.  相似文献   

5.
ObjectivesThe aim of this study was to compare 5-year cardiovascular, renal, and bioprosthetic valve durability outcomes in patients with severe aortic stenosis (AS) and chronic kidney disease (CKD) undergoing transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR).BackgroundPatients with severe AS and CKD undergoing TAVR or SAVR are a challenging, understudied clinical subset.MethodsIntermediate-risk patients with moderate to severe CKD (estimated glomerular filtration rate <60 mL/min/m2) from the PARTNER (Placement of Aortic Transcatheter Valve) 2A trial (patients randomly assigned to SAPIEN XT TAVR or SAVR) and SAPIEN 3 Intermediate Risk Registry were pooled. The composite primary outcome of death, stroke, rehospitalization, and new hemodialysis was evaluated using Cox regression analysis. Patients with and without perioperative acute kidney injury (AKI) were followed through 5 years. A core laboratory–adjudicated analysis of structural valve deterioration and bioprosthetic valve failure was also performed.ResultsThe study population included 1,045 TAVR patients (512 SAPIEN XT, 533 SAPIEN 3) and 479 SAVR patients. At 5 years, SAVR was better than SAPIEN XT TAVR (52.8% vs 68.0%; P = 0.04) but similar to SAPIEN 3 TAVR (52.8% vs 58.7%; P = 0.89). Perioperative AKI was more common after SAVR than TAVR (26.3% vs 10.3%; P < 0.001) and was independently associated with long-term outcomes. Compared with SAVR, bioprosthetic valve failure and stage 2 or 3 structural valve deterioration were significantly greater for SAPIEN XT TAVR (P < 0.05) but not for SAPIEN 3 TAVR.ConclusionsIn intermediate-risk patients with AS and CKD, SAPIEN 3 TAVR and SAVR were associated with a similar risk for the primary endpoint at 5 years. AKI was more common after SAVR than TAVR, and SAPIEN 3 valve durability was comparable with that of surgical bioprostheses.  相似文献   

6.
ObjectivesThe aim of this study was to assess the outcomes of severe prosthesis-patient mismatch (PPM) in the TVT (Transcatheter Valve Therapy) Registry in patients undergoing supra-annular transcatheter aortic valve replacement (TAVR) for de novo stenosis or failed surgical bioprostheses (transcatheter aortic valve [TAV]–in–surgical aortic valve [SAV]).BackgroundSevere PPM has been associated with adverse outcomes following TAVR, yet the clinical outcome of severe PPM after supra-annular TAVR is largely unknown.MethodsSupra-annular TAVR was performed in patients enrolled in the TVT Registry with de novo stenosis (n = 42,174) or TAV-in-SAV (n = 5,446). Valve Academic Research Consortium-3 criteria were used to define severe PPM. The clinical impact of severe PPM on 1-year mortality and valve-related readmission was assessed using multivariate regression. A generalized linear mixed model was used to evaluate predictors of severe PPM.ResultsSevere PPM was found in 5.3% of patients undergoing de novo TAVR and 27.0% of patients undergoing TAV-in-SAV. The presence of severe PPM was not significantly associated with 1-year mortality or valve-related readmissions in both groups. Mean aortic gradients were higher in patients with severe PPM than in those without severe PPM at 1 month (9.7 ± 5.7 mm Hg vs. 7.3 ± 4.0 mm Hg; p < 0.001) and 1 year (10.2 ± 6.4 mm Hg vs. 8.0 ± 4.3 mm Hg; p < 0.001). Pre-procedural factors, including a <20-mm aortic annulus, were positive predictors of severe PPM in patients undergoing de novo TAVR (area under the curve = 0.795) and TAV-in-SAV (area under the curve = 0.764).ConclusionsSevere PPM after supra-annular TAVR was not associated with increased 1-year mortality or valve-related readmissions. Longer-term follow-up is needed to determine if higher residual gradients in patients with severe PPM predict long-term outcomes. (STS/ACC Transcatheter Valve Therapy Registry [TVT Registry]; NCT01737528)  相似文献   

7.
BackgroundGreater early left ventricular mass index (LVMi) regression is associated with fewer hospitalizations 1 year after transcatheter aortic valve replacement (TAVR). The association between LVMi regression and longer-term post-TAVR outcomes is unclear.ObjectivesThe purpose of this study was to determine the association between LVMi regression at 1-year post-TAVR and clinical outcomes between 1 and 5 years.MethodsAmong intermediate- and high-risk patients who received TAVR in the PARTNER (Placement of Aortic Transcatheter Valves) I, II, and S3 trials or registries and were alive at 1 year, we included patients with baseline moderate or severe left ventricular hypertrophy (LVH) and paired measurements of LVMi at baseline and 1 year. The associations between LVMi regression (percent change between baseline and 1 year) and death or rehospitalization from 1 to 5 years were examined.ResultsAmong 1,434 patients, LVMi was 146 g/m2 (interquartile range [IQR]: 133 to 168 g/m2) at baseline and decreased 14.5% (IQR: 4.2% to 26.1%) to 126 g/m2 (IQR: 106 to 148 g/m2) at 1 year. After adjustment, greater LVMi regression at 1 year was associated with lower all-cause death (adjusted hazard ratio [aHR]: 0.95 per 10% decrease in LVMi; 95% confidence interval [CI]: 0.91 to 0.98; p = 0.004; aHR of the quartile with greatest vs. least LVMi regression: 0.61; 95% CI: 0.43 to 0.86; p = 0.005). Severe LVH at 1 year was observed in 39%, which was independently associated with increased all-cause death (aHR of severe LVH vs. no LVH: 1.71; 95% CI: 1.20 to 2.44; p = 0.003). Similar associations were found for rates of cardiovascular mortality and rehospitalization.ConclusionsAmong patients with moderate or severe LVH treated with TAVR who are alive at 1 year, greater LVMi regression at 1 year is associated with lower death and hospitalization rates to 5 years. These findings may have implications for the timing of valve replacement and the role of adjunctive medical therapy after TAVR.  相似文献   

8.
BackgroundSurgical aortic valve replacement and transcatheter aortic valve replacement (TAVR) are now both used to treat aortic stenosis in patients in whom life expectancy may exceed valve durability. The choice of initial bioprosthesis should therefore consider the relative safety and efficacy of potential subsequent interventions.ObjectivesThe aim of this study was to compare TAVR in failed transcatheter aortic valves (TAVs) versus surgical aortic valves (SAVs).MethodsData were collected on 434 TAV-in-TAV and 624 TAV-in-SAV consecutive procedures performed at centers participating in the Redo-TAVR international registry. Propensity score matching was applied, and 330 matched (165:165) patients were analyzed. Principal endpoints were procedural success, procedural safety, and mortality at 30 days and 1 year.ResultsFor TAV-in-TAV versus TAV-in-SAV, procedural success was observed in 120 (72.7%) versus 103 (62.4%) patients (p = 0.045), driven by a numerically lower frequency of residual high valve gradient (p = 0.095), ectopic valve deployment (p = 0.081), coronary obstruction (p = 0.091), and conversion to open heart surgery (p = 0.082). Procedural safety was achieved in 116 (70.3%) versus 119 (72.1%) patients (p = 0.715). Mortality at 30 days was 5 (3%) after TAV-in-TAV and 7 (4.4%) after TAV-in-SAV (p = 0.570). At 1 year, mortality was 12 (11.9%) and 10 (10.2%), respectively (p = 0.633). Aortic valve area was larger (1.55 ± 0.5 cm2 vs. 1.37 ± 0.5 cm2; p = 0.040), and the mean residual gradient was lower (12.6 ± 5.2 mm Hg vs. 14.9 ± 5.2 mm Hg; p = 0.011) after TAV-in-TAV. The rate of moderate or greater residual aortic regurgitation was similar, but mild aortic regurgitation was more frequent after TAV-in-TAV (p = 0.003).ConclusionsIn propensity score–matched cohorts of TAV-in-TAV versus TAV-in-SAV patients, TAV-in-TAV was associated with higher procedural success and similar procedural safety or mortality.  相似文献   

9.
ObjectivesThe aim of this study was to assess the incidence and prognostic impact of early and late postoperative atrial fibrillation or flutter (POAF) in patients with severe aortic stenosis (AS) treated with transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR).BackgroundThere is an ongoing controversy regarding the incidence, recurrence rate, and prognostic impact of early (in-hospital) POAF and late (postdischarge) POAF in patients with AS undergoing TAVR or SAVR.MethodsIn the PARTNER (Placement of Aortic Transcatheter Valve) 3 trial, patients with severe AS at low surgical risk were randomized to TAVR or SAVR. Analyses were performed in the as-treated population excluding patients with preexistent atrial fibrillation or flutter.ResultsAmong 781 patients included in the analysis, early POAF occurred in 152 (19.5%) (18 of 415 [4.3%] and 134 of 366 [36.6%] following TAVR and SAVR, respectively). Following discharge, 58 new or recurrent late POAF events occurred within 1 year following the index procedure in 55 of 781 patients (7.0%). Early POAF was not an independent predictor of late POAF following discharge (odds ratio: 1.04; 95% CI: 0.52-2.08; P = 0.90). Following adjustment, early POAF was not an independent predictor of the composite outcome of death, stroke, or rehospitalization (hazard ratio: 1.10; 95% CI: 0.64-1.92; P = 0.72), whereas late POAF was associated with an increased adjusted risk for the composite outcome (hazard ratio: 8.90; 95% CI: 5.02-15.74; P < 0.0001), irrespective of treatment modality.ConclusionsIn the PARTNER 3 trial, early POAF was more frequent following SAVR compared with TAVR. Late POAF, but not early POAF, was significantly associated with worse outcomes at 2 years, irrespective of treatment modality.  相似文献   

10.
ObjectivesThe purpose of this study was to evaluate clinical and echocardiographic outcome data of the CHOICE (Randomized Comparison of Transcatheter Heart Valves in High Risk Patients with Severe Aortic Stenosis: Medtronic CoreValve Versus Edwards SAPIEN XT) trial at 5 years.BackgroundThe CHOICE trial was designed to compare device performance of a balloon-expandable (BE) transcatheter heart valve (THV) versus a self-expanding (SE) THV.MethodsThe CHOICE trial is an investigator-initiated trial that randomized 241 high-risk patients with severe symptomatic aortic stenosis and an anatomy suitable for treatment with both BE and SE THVs to transfemoral transcatheter aortic valve replacement with either device. The primary endpoint was device success. Patients were followed up to 5 years, with assessment of clinical outcomes, and echocardiographic evaluation of valve function and THV durability.ResultsAfter 5 years, there were no statistically significant differences between BE and SE valves in the cumulative incidence of death from any cause (53.4% vs. 47.6%; p = 0.38), death from cardiovascular causes (31.6% vs. 21.5%; p = 0.12), all strokes (17.5% vs. 16.5%; p = 0.73), and repeat hospitalization for heart failure (28.9% vs. 22.5%; p = 0.75). SE patients had larger prosthetic valve area (1.6 ± 0.5 cm2 vs. 1.9 ± 0.5 cm2; p = 0.02) with a lower mean transprosthetic gradient (12.2 ± 8.7 mm Hg vs. 6.9 ± 2.7 mm Hg; p = 0.001) at 5 years. No differences were observed in the rates of paravalvular regurgitation. Clinical valve thrombosis occurred in 7 BE patients (7.3%) and 1 SE patient (0.8%; p = 0.06), and moderate or severe structural valve deterioration in 6 BE patients (6.6%) and no SE patient (0%; p = 0.018). The rate of bioprosthetic valve failure was low and not significantly different between both groups (4.1% vs. 3.4%; p = 0.63).ConclusionsFive-year follow-up of patients in the CHOICE trial revealed clinical outcomes after transfemoral transcatheter aortic valve replacement with early-generation BE and SE valves that were not statistically significantly different, with limited statistical power. Forward flow hemodynamics were significantly better with the SE valve. Moderate or severe structural valve deterioration was uncommon but occurred more frequently with the BE valve. (A Comparison of Transcatheter Heart Valves in High Risk Patients With Severe Aortic Stenosis: The CHOICE Trial [CHOICE]; NCT01645202)  相似文献   

11.
ObjectivesThe aim of this study was to evaluate and compare the outcomes of transcatheter self-expandable prostheses in patients with small annuli.BackgroundTranscatheter aortic heart valves appear to have better performance than surgical valves in terms of prosthesis-patient mismatch, especially in patients with aortic stenosis with small aortic annuli.MethodsTAVI-SMALL (International Multicenter Registry to Evaluate the Performance of Self-Expandable Valves in Small Aortic Annuli) is a retrospective registry of patients with severe aortic stenosis and small annuli (annular perimeter <72 mm or area <400 mm2 on computed tomography) treated with transcatheter self-expandable valves (n = 859; Evolut R, n = 397; Evolut PRO, n = 84; ACURATE, n = 201; Portico, n = 177). Primary endpoints were post-procedural mean aortic gradient, indexed effective orifice area, and rate of severe prosthesis-patient mismatch.ResultsPre-discharge gradients were consistently low in every group, with a slight benefit with the Evolut R (8.1 mm Hg; 95% confidence interval [CI]: 7.7 to 8.5 mm Hg) and Evolut PRO (6.9 mm Hg; 95% CI: 6.3 to 7.6 mm Hg) compared with the ACURATE (9.6 mm Hg; 95% CI: 8.9 to 10.2 mm Hg) and Portico (8.9 mm Hg; 95% CI: 8.2 to 9.6 mm Hg) groups (p < 0.001). Mean indexed effective orifice area was 1.04 cm2/m2 (95% CI: 1.01 to 1.08 cm2/m2) with a trend toward lower values with the Portico. No significant differences were reported in terms of severe prosthesis-patient mismatch (overall rate 9.4%; p = 0.134), permanent pacemaker implantation (15.6%), and periprocedural and 1-year adverse events. Pre-discharge more than mild paravalvular leaks were significantly more common with the Portico (19.2%) and less common with the Evolut PRO (3.6%) compared with the Evolut R (11.8%) and ACURATE (9%) groups.ConclusionsTranscatheter self-expandable valves showed optimal clinical and echocardiographic results in patients with small aortic annuli, although supra-annular functioning transcatheter heart valves seemed to slightly outperform intra-annular functioning ones. The role of transcatheter aortic valve replacement with self-expandable valves for the treatment of aortic stenosis in patients with small annuli needs to be confirmed in larger trials.  相似文献   

12.
ObjectivesThe aims of this study were to investigate the feasibility of coronary ostia cannulation after transcatheter aortic valve replacement (TAVR) and to assess potential predictors of coronary access impairment.BackgroundCertain data concerning the feasibility and reproducibility of coronary cannulation after TAVR are lacking.MethodsRE-ACCESS (Reobtain Coronary Ostia Cannulation Beyond Transcatheter Aortic Valve Stent) was an investigator-driven, single-center, prospective, registry-based study that enrolled consecutive patients undergoing TAVR using all commercially available devices. All patients underwent coronary angiography before and after TAVR. The primary endpoint was the rate of unsuccessful coronary ostia cannulation after TAVR. Secondary endpoints were the identification of factors associated with the inability to selectively cannulate coronary ostia after TAVR.ResultsAmong 300 patients enrolled in the RE-ACCESS study from December 2018 to January 2020, a total of 23 cases (7.7%) of unsuccessful coronary cannulation after TAVR were documented. This issue occurred in 22 of 23 cases with the use of Evolut R/PRO transcatheter aortic valves (TAVs) (17.9% vs. 0.4%; p < 0.01). In multivariate analysis, the use of Evolut R/PRO TAVs (odds ratio [OR]: 29.6; 95% confidence interval [CI]: 2.6 to 335.0; p < 0.01), the TAV–sinus of Valsalva relation (OR: 1.1 per 1-mm increase; 95% CI: 1.0 to 1.2; p < 0.01), and the mean TAV implantation depth (OR: 1.7 per 1-mm decrease; 95% CI: 1.3 to 2.3; p < 0.01) were found to be independent predictors of unsuccessful coronary cannulation after TAVR. A model combining these factors was demonstrated to predict with very high accuracy the risk for unsuccessful coronary cannulation after TAVR (area under the curve: 0.94; p < 0.01).ConclusionsUnsuccessful coronary cannulation following TAVR was observed in 7.7% of patients and occurred almost exclusively in those receiving Evolut TAVs. The combination of Evolut TAV, a higher TAV–sinus of Valsalva relation, and implantation depth predicts with high accuracy the risk for unsuccessful coronary cannulation after TAVR. (Reobtain Coronary Ostia Cannulation Beyond Transcatheter Aortic Valve Stent [RE-ACCESS]; NCT04026204)  相似文献   

13.
BackgroundTranscatheter aortic valve replacement (TAVR) use is increasing in patients with longer life expectancy, yet robust data on the durability of transcatheter heart valves (THVs) are limited. Redo-TAVR may play a key strategy in treating patients in whom THVs fail.ObjectivesThe authors sought to examine outcomes following redo-TAVR.MethodsThe Redo-TAVR registry collected data on consecutive patients who underwent redo-TAVR at 37 centers. Patients were classified as probable TAVR failure or probable THV failure if they presented within or beyond 1 year of their index TAVR, respectively.ResultsAmong 63,876 TAVR procedures, 212 consecutive redo-TAVR procedures were identified (0.33%): 74 within and 138 beyond 1 year of the initial procedure. For these 2 groups, TAVR-to-redo-TAVR time was 68 (38 to 154) days and 5 (3 to 6) years. The indication for redo-TAVR was THV stenosis in 12 (16.2%) and 51 (37.0%) (p = 0.002) and regurgitation or combined stenosis–regurgitation in 62 (83.8%) and 86 (62.3%) (p = 0.028), respectively. Device success using VARC-2 criteria was achieved in 180 patients (85.1%); most failures were attributable to high residual gradients (14.1%) or regurgitation (8.9%). At 30-day and 1-year follow-up, residual gradients were 12.6 ± 7.5 mm Hg and 12.9 ± 9.0 mm Hg; valve area 1.63 ± 0.61 cm2 and 1.51 ± 0.57 cm2; and regurgitation ≤mild in 91% and 91%, respectively. Peri-procedural complication rates were low (3 stroke [1.4%], 7 valve malposition [3.3%], 2 coronary obstruction [0.9%], 20 new permanent pacemaker [9.6%], no mortality), and symptomatic improvement was substantial. Survival at 30 days was 94.6% and 98.5% (p = 0.101) and 83.6% and 88.3% (p = 0.335) at 1 year for patients presenting with early and late valve dysfunction, respectively.ConclusionsRedo-TAVR is a relatively safe and effective option for selected patients with valve dysfunction after TAVR. These results are important for applicability of TAVR in patients with long life expectancy in whom THV durability may be a concern.  相似文献   

14.
BackgroundCurrent expected normal echocardiographic measures of transcatheter heart valve (THV) function were derived from pooled cohorts of the randomized trials; however, THV function by flow state before or following transcatheter aortic valve replacement (TAVR) has not been previously reported.ObjectivesThis study sought to assess the expected normal echocardiographic hemodynamics for the balloon-expandable THV grouped by stroke volume index (SVI).MethodsPatients with severe aortic stenosis enrolled in PARTNER (Placement of Aortic Transcatheter Valves) 1 (high/extreme surgical risk), PARTNER 2 (intermediate surgical risk), or PARTNER 3 (low surgical risk) trials with complete core laboratory echocardiography were included. Patients were grouped by low-flow (SVILOW <35 mL/m2) and normal-flow (SVINORMAL ≥35 mL/m2). Mean gradient, effective orifice area (EOA), and Doppler velocity index (DVI) were collected at baseline and at 30 days post-TAVR. Prosthesis-patient mismatch (PPM) was both calculated and predicted from normative data, using defined criteria.ResultsIn the entire population (N = 4,991), mean age was 81.8 years, 58% of patients were male, and 42% had low flow. Compared with patients with baseline SVINORMAL, those with SVILOW were more likely to be male; have more comorbidities; and lower left ventricular ejection fraction, mean gradient, and EOA. Post-TAVR, SVILOW increased to SVINORMAL in 17.3% and SVINORMAL decreased to SVILOW in 12.3% of patients. Using baseline SVI, follow-up EOA, mean gradient, and DVI for patients with SVILOW tended to be lower than for patients with SVINORMAL. Using the post-TAVR SVI, follow-up EOA, mean gradient, and DVI were significantly lower for patients with SVILOW than for those with SVINORMAL (P < 0.001 for all). The incidence of calculated, but not predicted, severe PPM was higher in patients with low flow than it was in patients with normal flow, suggesting pseudo-PPM in the presence of low flow.ConclusionsThis study demonstrates that flow affects THV hemodynamics and both baseline and follow-up SVI should be considered when predicting THV hemodynamics prior to TAVR, as well as assessing valve function following valve implantation.  相似文献   

15.
ObjectivesThis study sought to evaluate the association between severity of left ventricular hypertrophy (LVH) before transcatheter aortic valve replacement (TAVR) and outcomes out to 5 years.BackgroundPrior studies assessing the association between baseline LVH and outcomes after surgical or TAVR for aortic stenosis (AS) have yielded conflicting results.MethodsPatients with severe symptomatic AS at intermediate or high risk in the PARTNER (Placement of Aortic Transcatheter Valve) 1, 2, and S3 trials and registries who received TAVR and had baseline measurements for left ventricular mass index (LVMi) were analyzed. The presence and severity of LVH was determined by LVMi using American Society of Echocardiography sex-specific cutoffs.ResultsAmong 4,280 patients, those with no (n = 1,325), mild (n = 777), moderate (n = 628), and severe (n = 1,550) LVH had 5-year rates of death of 32.8%, 37.3%, 37.2%, and 44.8%, respectively (p < 0.001), and 5-year rates of cardiovascular (CV) death or rehospitalization of 33.6%, 39.2%, 42.4%, and 49.2%, respectively (p < 0.001). After adjustment, severe LVH (compared with no LVH) was associated with increased all-cause death (adjusted hazard ratio: 1.16; 95% confidence interval: 1.00 to 1.34; p = 0.04) and CV death or rehospitalization (adjusted hazard ratio: 1.34; 95% confidence interval: 1.16 to 1.54; p < 0.001), but no increased hazard was observed for mild or moderate LVH. In spline analyses performed in males and females separately, there was a consistent linear association between increased LVMi and an increased adjusted hazard of CV mortality or rehospitalization. A similar relationship was observed for all-cause death in females, but not males.ConclusionsSevere baseline LVH is associated with higher 5-year death and rehospitalization rates after TAVR. These findings may have implications for the optimal timing of valve replacement and the potential role for medical therapy to slow or prevent LVH as AS progresses before valve replacement, but further studies are needed.  相似文献   

16.
ObjectivesThis study aimed to compare incidence and impact of measured prosthesis-patient mismatch (PPMM) versus predicted PPM (PPMP) after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR).BackgroundTAVR studies have used measured effective orifice area indexed (EOAi) to body surface area (BSA) to define PPM, but most SAVR series have used predicted EOAi. This difference may contribute to discrepancies in incidence and outcomes of PPM between series.MethodsThe study analyzed SAVR patients from the PARTNER (Placement of Aortic Transcatheter Valves) 2A trial and TAVR patients from the PARTNER 2 SAPIEN 3 Intermediate Risk registry. PPM was classified as moderate if EOAi ≤0.85 cm2/m2 (≤0.70 if obese: body mass index ≥30 kg/m2) and severe if EOAi ≤0.65 cm2/m2 (≤0.55 if obese). PPMM was determined by the core lab–measured EOAi on 30-day echocardiogram. PPMP was determined by 2 methods: 1) using normal EOA reference values previously reported for each valve model and size (PPMP1; n = 929 SAVR, 1,069 TAVR) indexed to BSA; and 2) using normal reference EOA predicted from aortic annulus size measured by computed tomography (PPMP2; n = 864 TAVR only) indexed to BSA. Primary endpoint was the composite of 5-year all-cause death and rehospitalization.ResultsThe incidence of moderate and severe PPMP was much lower than PPMM in both SAVR (PPMP1: 28.4% and 1.2% vs. PPMM: 31.0% and 23.6%) and TAVR (PPMP1: 21.0% and 0.1% and PPMP2: 17.0% and 0% vs. PPMM: 27.9% and 5.7%). The incidence of severe PPMM and severe PPMP1 was lower in TAVR versus SAVR (P < 0.001). The presence of PPM by any method was associated with higher transprosthetic gradient. Severe PPMP1 was independently associated with events in SAVR after adjustment for sex and Society of Thoracic Surgeons score (hazard ratio: 3.18;95% CI: 1.69-5.96; P < 0.001), whereas no association was observed between PPM by any method and outcomes in TAVR.ConclusionsEOAi measured by echocardiography results in a higher incidence of PPM following SAVR or TAVR than PPM based on predicted EOAi. Severe PPMP is rare (<1.5%), but is associated with increased all-cause death and rehospitalization after SAVR, whereas it is absent following TAVR.  相似文献   

17.
ObjectivesThe aim of this study was to assess the association between Doppler velocity index (DVI) and 2-year outcomes for balloon-expandable SAPIEN 3 transcatheter aortic valve replacement (TAVR) and for surgical aortic valve replacement (SAVR).BackgroundDVI >0.35 is normal for a prosthetic valve, but recent studies suggest that DVI <0.50 is associated with poor outcomes following TAVR.MethodsPatients with severe aortic stenosis enrolled in the PARTNER (Placement of Aortic Transcatheter Valve) 2 (intermediate surgical risk) or PARTNER 3 (low surgical risk) trial undergoing TAVR (n = 1,450) or SAVR (n = 1,303) were included. Patients were divided into 3 DVI groups on the basis of core laboratory–assessed discharge or 30-day echocardiograms: DVILOW (≤0.35), DVIINTERMEDIATE (>0.35 to ≤0.50), and DVIHIGH (>0.50). Two-year outcomes were assessed.ResultsFollowing TAVR, there were no differences among the 3 DVI groups in composite outcomes of death, stroke, or rehospitalization or in any individual components of 2-year outcomes (P > 0.70 for all). Following SAVR, there was no difference among DVI groups in the composite outcome (P = 0.27), but there was a significant association with rehospitalization (P = 0.02). Restricted cubic-spline analysis for combined outcomes showed an increased risk with post-SAVR DVI ≤0.35 but no relationship post-TAVR. DVI ≤0.35 was associated with increased 2-year composite outcome for SAVR (HR: 1.81; 95% CI: 1.29–2.54; P < 0.001), with no adverse outcomes for TAVR (P = 0.86).ConclusionsIn intermediate- and low-risk cohorts of the PARTNER trials, DVI ≤0.35 predicted worse 2-year outcomes following SAVR, driven primarily by rehospitalization, with no adverse outcomes associated with DVI following TAVR with the balloon-expandable SAPIEN 3 valve.  相似文献   

18.
ObjectivesThis study sought to predict whether different methods of calculating the implantation depth (ID) influence clinical and hemodynamic outcome reporting in patients undergoing transcatheter aortic valve replacement (TAVR) with a self-expandable device.BackgroundDifferent approaches exist to calculate the ID, which may influence uniform and reliable reporting because the updated Valve Academic Research Consortium (VARC-2) criteria do not provide specific instructions.MethodsThe clinical and hemodynamic outcomes of 258 patients undergoing TAVR with a third-generation self-expandable device were analyzed with regard to the method used to assess the ID as follows: arithmetic mean, the arithmetic mean of the measured distances from the noncoronary cusp and the left coronary cusp to the distal prosthesis end; noncoronary cusp distance, the distance from the noncoronary cusp to the distal prosthesis end; and deepest edge, the deepest edge of the distal prosthesis end.ResultsRegardless of the measurement method, the optimal ID (OID) was reached in <30% (arithmetic mean, 25.4%; noncoronary cusp distance, 28.4%; deepest edge, 20.5%; p = 0.008). The deepest edge method is the most stringent to differentiate the relevant outcome parameters, such as the need for permanent pacemaker implantation (OID 3.7% vs. no OID 14.6%; p = 0.033). The hemodynamic outcome (i.e., mean pressure gradient reduction after TAVR: OID 7.4 ± 3.4 mm Hg vs. no OID 8.3 ± 4.0 mm Hg; p = 0.093) was not affected.ConclusionsThe OID was reached in <30% of TAVR procedures. The various methods applied for ID calculation significantly influence the outcome reporting and do not allow a uniform perception of the ID. (Multi Modal Cardiac Imaging Prior Transcatheter Aortic Valve Implantation; NCT01805739)  相似文献   

19.
ObjectivesThe aim of this study was to evaluate device success of transcatheter aortic valve replacement (TAVR) using new-generation balloon-expandable prostheses with or without balloon aortic valvuloplasty (BAV).BackgroundRandomized studies are lacking comparing TAVR without BAV against the conventional technique of TAVR with BAV.MethodsDIRECTAVI (Direct Transcatheter Aortic Valve Implantation) was an open-label noninferiority study that randomized patients undergoing TAVR using the Edwards SAPIEN 3 valve with or without prior balloon valvuloplasty. The primary endpoint was the device success rate according to Valve Academic Research Consortium-2 criteria, which was evaluated using a 7% noninferiority margin. The secondary endpoint included procedural and 30-day adverse events.ResultsDevice success was recorded for 184 of 236 included patients (78.0%). The rate of device success in the direct implantation group (n = 97 [80.2%]) was noninferior to that in the BAV group (n = 87 [75.7%]) (mean difference 4.5%; 95% confidence interval: −4.4% to 13.4%; p = 0.02 for noninferiority). No severe prosthesis-patient mismatch or severe aortic regurgitation occurred in any group. In the direct implantation group, 7 patients (5.8%) required BAV to cross the valve. Adverse events were related mainly to pacemaker implantation (20.9% in the BAV group vs. 19.0% in the direct implantation group; p = 0.70). No significant difference was found between the 2 strategies in duration of procedure, contrast volume, radiation exposure, or rate of post-dilatation.ConclusionsDirect TAVR without prior BAV was noninferior to the conventional strategy using BAV with new-generation balloon-expandable valves, but without procedural simplification. BAV was needed to cross the valve in a few patients, suggesting a need for upstream selection on the basis of patient anatomy. (TAVI Without Balloon Predilatation [of the Aortic Valve] SAPIEN 3 [DIRECTAVI]; NCT02729519)  相似文献   

20.
BackgroundThe randomized SOLVE-TAVI (compariSon of secOnd-generation seLf-expandable vs. balloon-expandable Valves and gEneral vs. local anesthesia in Transcatheter Aortic Valve Implantation) trial compared newer-generation self-expanding valves (SEV) and balloon-expandable valves (BEV) as well as local anesthesia with conscious sedation (CS) and general anesthesia (GA) in patients undergoing transfemoral transcatheter aortic valve replacement (TAVR). Both strategies showed similar outcomes at 30 days.ObjectivesThe purpose of this study was to compare clinical outcomes during 1-year follow-up in the randomized SOLVE-TAVI trial.MethodsUsing a 2 × 2 factorial design 447 intermediate- to high-risk patients with severe, symptomatic aortic stenosis were randomly assigned to transfemoral TAVR using either the SEV (Evolut R, Medtronic Inc., Minneapolis, Minnesota) or the BEV (Sapien 3, Edwards Lifesciences, Irvine, California) as well as CS or GA at 7 sites.ResultsIn the valve-comparison strategy, rates of the combined endpoint of all-cause mortality, stroke, moderate or severe paravalvular leakage, and permanent pacemaker implantation were similar between the BEV and SEV group (n = 84, 38.3% vs. n = 87, 40.4%; hazard ratio: 0.94; 95% confidence interval: 0.70 to 1.26; p = 0.66) at 1 year. Regarding the anesthesia comparison, the combined endpoint of all-cause mortality, stroke, myocardial infarction, and acute kidney injury occurred with similar rates in the GA and CS groups (n = 61, 25.7% vs. n = 54, 23.8%; hazard ratio: 1.09; 95% confidence interval: 0.76 to 1.57; p = 0.63).ConclusionsIn intermediate- to high-risk patients undergoing transfemoral TAVR, newer-generation SEV and BEV as well as CS and GA showed similar clinical outcomes at 1 year using a combined clinical endpoint. (SecOnd-generation seLf-expandable Versus Balloon-expandable Valves and gEneral Versus Local Anesthesia in TAVI [SOLVE-TAVI]; NCT02737150)  相似文献   