首页 | 本学科首页   官方微博 | 高级检索  
     


Quantitative analysis of liver function using superparamagnetic iron oxide- and Gd-EOB-DTPA-enhanced MRI: comparison with Technetium-99m galactosyl serum albumin scintigraphy
Authors:Nishie Akihiro  Ushijima Yasuhiro  Tajima Tsuyoshi  Asayama Yoshiki  Ishigami Kousei  Kakihara Daisuke  Nakayama Tomohiro  Takayama Yukihisa  Okamoto Daisuke  Abe Koichiro  Obara Makoto  Yoshimitsu Kengo  Honda Hiroshi
Affiliation:Department of Clinical Radiology, Graduate School of Medical Sciences, Kyushu University, 3-1-1 Maidashi, Higashi-ku, Fukuoka 812-8582, Japan. anishie@radiol.med.kyushu-u.ac.jp
Abstract:

Purpose

To examine whether or not the parameters regarding the signal intensity of the liver parenchyma on superparamagnetic iron oxide (SPIO)- and gadolinium ethoxybenzyl diethylenetriamine pentaacetic acid (Gd-EOB-DTPA)-enhanced MRI are correlated with the parameters of Technetium-99m galactosyl serum albumin (99mTc-GSA) scintigraphy.

Materials and methods

This retrospective study consisted of 55 and 33 patients who underwent SPIO- and Gd-EOB-DTPA-enhanced MRI in addition to 99mTc-GSA scintigraphy, respectively. For each patient, we calculated Pre R2* and Pre R2, which are equivalent to R2* (=1/T2*) and R2 (=1/T2) values of the liver parenchyma; ΔR2* and ΔR2, which represent differences in R2* and R2 values of the liver parenchyma before and after administration of SPIO; and the increase rates of both the liver-to-spleen signal intensity ratio (LSR) and the liver-to-major psoas muscle signal intensity ratio (LMR) on the hepatobiliary phase compared with the precontrast image. For 99mTc-GSA scintigraphy, the receptor index LHL15 and the blood clearance index HH15 were recorded.

Results

Regression analysis showed a moderate correlation between Pre R2* and LHL15 (P < 0.05). Mild to moderate correlations were also obtained between any combination of ΔR2* and ΔR2 on the one hand, and LHL15 and HH15 on the other (P < 0.05). There were moderate correlations between any combination of increase rates of LSR and LMR on the one hand, and LHL15 and HH15 on the other (P < 0.05–0.001).

Conclusion

Pre R2*, ΔR2*, ΔR2 and the increase rates of LSR and LMR could be used as quantitative indicators of liver function.
Keywords:Superparamagnetic iron oxide   T2* map   T2 map   Gd-EOB-DTPA   99mTc-GSA   Liver function
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏