首页 | 本学科首页   官方微博 | 高级检索  
     


1-Year Outcomes of Cardioband Tricuspid Valve Reconstruction System Early Feasibility Study
Affiliation:1. Lankenau Heart Institute, Wynnewood, Pennsylvania, USA;2. University of Virginia Health System Hospital, Charlottesville, Virginia, USA;3. Baylor Scott and White The Heart Hospital, Plano, Texas, USA;4. Columbia University Medical Center, New York, New York, USA;5. Atlantic Medical Group, Morristown Medical Center, Morristown, New Jersey, USA;6. Mayo Clinic, Rochester, Minnesota, USA;7. Intermountain Healthcare, Salt Lake City, Utah, USA;8. University of Washington, Seattle, Washington, USA;9. Cardiovascular Research Foundation, New York, New York, USA;10. Institut Universitaire de Cardiologie et de Pneumologie, Université Laval, Quebec, Canada;11. Northwestern University Feinberg School of Medicine, Chicago, Illinois, USA
Abstract:BackgroundTricuspid regurgitation (TR) is prevalent and undertreated, with mortality and morbidity increasing with TR severity. Given poor outcomes with medical therapy and high in-hospital mortality for isolated tricuspid valve surgery, emerging transcatheter repair devices offer a promising alternative.ObjectivesThe Edwards Cardioband Tricuspid Valve Reconstruction System Early Feasibility study (NCT03382457) evaluates the treatment of functional TR via annular reduction with the Cardioband Tricuspid Valve Reconstruction System (Edwards Lifesciences).MethodsPatients with ≥ moderate functional TR were eligible for this prospective, single-arm multicenter study. At 1 year, patients were evaluated for echocardiographic parameters, clinical and quality-of-life measures, and major adverse events.ResultsThe 37 patients enrolled had a mean age of 78 years; 76% were female; and they had ≥ severe functional (97.3%) or mixed (2.7%) TR, atrial flutter/fibrillation (97%), and New York Heart Association functional class III/IV (65%). At 1 year, 73.0% achieved ≤ moderate TR (P < 0.0001), and 73.1% had ≥2 grade reductions. Echocardiography showed significant reductions in the tricuspid annulus diameter (P < 0.0001), mean vena contracta (P < 0.0001), proximal isovelocity surface area effective regurgitant orifice area (P < 0.0001), right ventricular end-diastolic diameter (P < 0.0001), and inferior vena contracta (P = 0.0006). New York Heart Association functional class improved significantly (P < 0.0001), with 92.3% achieving class I/II, and Kansas City Cardiomyopathy Questionnaire scores improved by 19.0 points (P < 0.0001). One-year cardiovascular mortality was 8.1%, reinterventions were necessary in 5.4%, major access site complications occurred in 8.1%, and severe bleeding was noted in 35.1% of patients. Kaplan-Meier estimates of survival and freedom from heart failure rehospitalization were 85.9% and 88.7%, respectively.ConclusionsOne-year experience using the Cardioband system for tricuspid valve repair shows high survival and low rehospitalization rates with durable outcomes in TR reduction and echocardiographic, clinical, and quality-of-life outcomes.
Keywords:annular reduction  Cardioband  functional tricuspid regurgitation  transcatheter tricuspid valve interventions  tricuspid regurgitation  6MWD"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0040"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  six-minute walk distance  EROA"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0050"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  effective regurgitant orifice area  KCCQ"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0060"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  Kansas City Cardiomyopathy Questionnaire  LVEF"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0070"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  left ventricular ejection fraction  MAE"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0080"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  major adverse event(s)  NYHA"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0090"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  New York Heart Association  PISA"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0100"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  proximal isovelocity surface area  TEE"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0110"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  transesophageal echocardiography  TR"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0120"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  tricuspid regurgitation  TTE"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0130"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  transthoracic echocardiography  TV"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0140"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  tricuspid valve
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号