首页 | 本学科首页   官方微博 | 高级检索  
检索        


Risk Assessment of Coronary Obstruction During Transcatheter Aortic Valve Replacement: Insights From Post-BASILICA Computed Tomography
Institution:1. Department of Structural Heart Disease/Cardiology, Heart Center Leipzig at University of Leipzig, Leipzig, Germany;2. Department of Diagnostic and Interventional Radiology, Heart Center Leipzig at University of Leipzig, Leipzig, Germany;3. Department of Structural Heart Disease/Cardiac Surgery, Heart Center Leipzig at University of Leipzig, Leipzig, Germany;4. Department of Cardiology, Friedrich-Alexander-Universität Erlangen-Nürnberg, Erlangen, Germany
Abstract:ObjectivesThe aim of this study was to examine the predictive value of preprocedural computed tomography (CT)–based risk stratification of coronary obstruction during transcatheter aortic valve replacement (TAVR) on the basis of geometric measurements on postprocedural CT.BackgroundProper patient selection for additional procedures to prevent coronary obstruction during TAVR has not been adequately evaluated.MethodsPre- and postprocedural computed tomographic scans of 28 patients treated using bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction (BASILICA) and TAVR were analyzed. Using the postprocedural computed tomographic images, threatened coronary obstruction (TCO) was defined as: 1) ostial obstruction (adherence of the transcatheter heart valve THV] to the coronary ostium with leaflet extension above the ostium); and/or 2) sinus sequestration (THV adherence to the sinotubular junction STJ] with leaflet extension above the STJ) and was substratified into complete and incomplete types.ResultsA total of 51 leaflets were evaluated (88% surgical tissue valves) after excluding leaflets not visible on CT (n = 5). On postprocedural CT, complete TCO was observed in 25.4% (13 of 51 leaflets). On preprocedural CT, leaflets were at high risk for complete TCO (incidence 53%) if the virtual THV–to–coronary distance (VTC) was <3.0 mm, or if the virtual THV–to–STJ distance (VTSTJ) was <1.0 mm with STJ height ? leaflet length <0 mm (leaflet-STJ mismatch). Leaflets were at low risk (incidence 0%) if the VTC was ≥3 mm and VTSTJ was ≥3.0 mm or STJ height ? leaflet length was ≥+2.0 mm. Of 28 leaflets treated using BASILICA, complete TCO was seen in 35.7% (n = 10), due to sinus sequestration (100%) with coexisting ostial obstruction (30%). Actual coronary events occurred in 7.1% (n = 2) because of leaflet prolapse, corresponding to an absolute risk reduction by BASILICA of 29% (P = 0.021).ConclusionsRisk assessment of coronary obstruction after TAVR may improve with a multiparametric approach incorporating VTC, VTSTJ, and leaflet-STJ mismatch. BASILICA appeared to reduce actual coronary events even in leaflets with anticipated coronary obstruction.
Keywords:BASILICA  computed tomography  coronary obstruction  transcatheter aortic valve replacement  BASILICA"}  {"#name":"keyword"  "$":{"id":"kwrd0035"}  "$$":[{"#name":"text"  "_":"bioprosthetic or native aortic scallop intentional laceration to prevent iatrogenic coronary artery obstruction  CT"}  {"#name":"keyword"  "$":{"id":"kwrd0045"}  "$$":[{"#name":"text"  "_":"computed tomography  STJ"}  {"#name":"keyword"  "$":{"id":"kwrd0055"}  "$$":[{"#name":"text"  "_":"sinotubular junction  TAVR"}  {"#name":"keyword"  "$":{"id":"kwrd0065"}  "$$":[{"#name":"text"  "_":"transcatheter aortic valve replacement  TCO"}  {"#name":"keyword"  "$":{"id":"kwrd0075"}  "$$":[{"#name":"text"  "_":"threatened coronary obstruction  THV"}  {"#name":"keyword"  "$":{"id":"kwrd0085"}  "$$":[{"#name":"text"  "_":"transcatheter heart valve  VTC"}  {"#name":"keyword"  "$":{"id":"kwrd0095"}  "$$":[{"#name":"text"  "_":"virtual transcatheter heart valve–to–coronary distance  VTSTJ"}  {"#name":"keyword"  "$":{"id":"kwrd0105"}  "$$":[{"#name":"text"  "_":"virtual transcatheter heart valve–to–sinotubular junction distance
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号