首页 | 本学科首页   官方微博 | 高级检索  
     


International Hand Function Study Following Distal Radial Access: The RATATOUILLE Study
Affiliation:1. Division of Cardiology, Sant’Eugenio Hospital, Rome, Italy;2. Cardiology Department, St. Jansdal Hospital, Harderwijk, the Netherlands;3. Hartdokters, Amsterdam, the Netherlands;4. University Heart Center, Medical University of Graz, Graz, Austria;5. Gosford Hospital, Gosford, New South Wales, Australia;6. Cardiology Department, Athens Naval Hospital, Athens, Greece;7. Hospital Dona Helena, Joinville, Brazil;8. QRA Medicina Especializada, Universidad San Francisco, Quito, Ecuador;9. Clínica Cardiovascular del Caribe, Monteria, Colombia;10. Golden Jubilee National Hospital, Glasgow, United Kingdom;11. Independent Researcher, Bussum, the Netherlands;12. University of Amsterdam, Amsterdam, the Netherlands
Abstract:BackgroundDistal radial access (DRA) has been proposed to improve procedure ergonomics and favor radial artery patency. Although promising data, nothing is known on evolving hand function after DRA.ObjectivesThis study sought to comprehensively evaluate hand function in patients undergoing DRA.MethodsReal-world patients undergoing DRA undertook a thorough multimodality assessment of hand function implementing multidomain questionnaires (Disabilities of the Arm, Shoulder and Hand and Levine-Katz), and motor (pinch grip test) and sensory (Semmes-Weinstein monofilaments test) examinations of both hands. All assessments were performed at preprocedural baseline and planned at 1-, 6-, and 12-month follow-up (FU). Adverse clinical and procedural events were documented too.ResultsData of 313 patients (220 men, age 66 ± 10 years) from 9 international centers were analyzed. The Disabilities of the Arm, Shoulder and Hand and the Levine-Katz scores slightly improved from baseline to FU (P = 0.008 and P = 0.029, respectively). Pinch strength mildly improved from baseline to FU (P < 0.001 for both the left and right hands). Similarly, touch pressure threshold appeared to faintly improve in both the left and right hands (P < 0.012 for all the sites). For both motor and sensory function tests, comparable findings were found for the DRA hand and the contralateral one, with no significant differences between them. Repeated assessment of all tests over all FU time points similarly showed lack of worsening hand function. Access-related adverse events included 19 harmless bleedings and 3 forearm radial artery and 3 distal radial artery occlusions. None affected hand function at FU.ConclusionsIn a systematic multidimensional assessment, DRA was not associated with hand function impairment. Moreover, DRA emerges as a safe alternative vascular access.
Keywords:anatomical snuffbox  distal radial access  hand function  motor  sensory  transradial access  BARC"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0045"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  Bleeding Academic Research Consortium  DASH"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0055"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  Disabilities of the Arm, Shoulder and Hand  DRA"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0065"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  distal radial access  MCID"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0075"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  minimal clinically important difference  RAO"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0085"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  radial artery occlusion  TRA"  },{"  #name"  :"  keyword"  ,"  $"  :{"  id"  :"  kwrd0095"  },"  $$"  :[{"  #name"  :"  text"  ,"  _"  :"  transradial access
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号