首页 | 本学科首页   官方微博 | 高级检索  
     


A new surgical technique using steel suture for trans-scleral fixation of posterior chamber intraocular lenses
Authors:Jagat Ram  Nishant Gupta  Manish Chaudhary  Neelam Verma
Affiliation:Advanced Eye Centre, Post Graduate Institute of Medical Education and Research, Chandigarh, India
Abstract:

Background:

A new emerging complication of trans-scleral fixation of posterior chamber (PC) intraocular lens (IOL) with polypropylene suture is high rates of spontaneous dislocation of the IOL due to disintegration or breakage of suture.

Materials:

We report a new surgical technique of trans-scleral fixation of posterior chamber intraocular lens (SF PCIOL) with steel suture to eliminate the complication of dislocation of IOL fixed with polypropylene suture in one adult and a child.

Results:

We successfully achieved stable fixation and good centration of IOL after SF PCIOL with steel suture in these patient having inadequate posterior capsular support. Both eyes achieved best corrected visual acuity 20/40 at 18 months follow-up.

Conclusions:

Steel suture is a viable option for trans-scleral fixation of posterior chamber intraocular lens.
Keywords:Aphakia   inadequate capsular support   pediatric aphakia   secondary intraocular lens implantation   steel suture   trans-scleral fixation   vanadium steel
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号