首页 | 本学科首页   官方微博 | 高级检索  
     


Real-world comparison between the Tonopen and Goldmann applanation tonometry in a university glaucoma clinic
Authors:Blumberg  Max J.  Varikuti  Venkata N. V.  Weiner  Asher
Affiliation:1.Jacobs School of Medicine and Biomedical Sciences, University at Buffalo/State University of New York (SUNY), Buffalo, NY, USA
;3.Department of Ophthalmology and Ira G. Ross Eye Institute, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo/State University of New York (SUNY), 1176 Main Street, Buffalo, NY, 14209, USA
;
Abstract:Purpose

To determine whether Tonopen intraocular pressure (IOP) measurements by Ophthalmic technicians are interchangeable with Goldmann applanation tonometry (GAT) by a specialist in our glaucoma clinic.

Methods

Ophthalmic technician Tonopen and glaucoma specialist GAT IOP measurements were performed on both undilated eyes of 300 consecutive patients during the same visit to our glaucoma clinic.

Results

Among all 600 eyes of 300 patients (age 65.4, range: 23–92 years, male: 44.3%), Tonopen and GAT IOPs were similar (15.5?±?0.6 vs. 15.4?±?0.7 mmHg, respectively, p?=?0.63) and directly correlated (r2?=?0.58, p?p?=?0.024) and in the left eyes (17.0?±?1.0 vs. 16.3?±?1.0 mmHg, p?=?0.029). In all 300 right eyes, Tonopen underestimated IOP in 48.3% of eyes and overestimated in 39% (difference range: (???)14 to (?+?)12 mmHg), with IOP difference?>??±?3 mmHg in 34% of eyes. In eyes with GAT IOP?≥?22 mmHg, Tonopen IOP was significantly lower (24.7?±?2.6, range: 11–43 mmHg vs. 28.2?±?2.2, range: 22–43 mmHg, p?=?0.0002, mean difference:???3.6?±?1.7 mmHg), and the Tonopen measured IOP?≤?21 mmHg in 33.3% of eyes. In eyes with Tonopen IOP?≤?10 mmHg GAT measured IOP of 11–17 mmHg in 65.7% of eyes.

Conclusions

Tonopen may mask a third of eyes with elevated IOP and two third of eyes with potentially above-goal IOP. The Tonopen may not be interchangeable with GAT or sufficiently reliable for patient management or screening in our glaucoma clinic. However, further study is recommended to assess the limitations of the Tonopen IOP measurements in eyes with higher or lower GAT IOPs.

Clinical Trials Registration

The Institutional review board, Jacobs School of Medicine and Biomedical Sciences, University at Buffalo, State University of New York, Buffalo, NY does not require this retrospective study to register.

Keywords:
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号