Endoscopic clip application for closure of esophageal perforations caused by EMR |
| |
Authors: | Shimizu Yuichi Kato Mototsugu Yamamoto Junji Nakagawa Souichi Komatsu Yoshito Tsukagoshi Hiroyuki Fujita Masahiro Hosokawa Masao Asaka Masahiro |
| |
Affiliation: | Third Department of Internal Medicine, Hokkaido University School of Medicine, Sapporo, Japan. |
| |
Abstract: | BACKGROUND: With increasing use of EMR for early stage esophageal carcinoma, the number of cases of iatrogenic esophageal perforation is likely to increase. This study evaluated the results of endoscopic clip application for treatment of perforations caused by EMR in patients with esophageal carcinoma. METHODS: Among 185 patients who underwent EMR for esophageal carcinoma, esophageal perforation occurred in 3 patients (1.6%). Metallic clips were immediately applied endoscopically to close the perforations. OBSERVATIONS: All 3 patients were observed closely and were managed conservatively (intravenous hyperalimentation, antibiotics) after closure of the perforation. They were discharged without any further serious complication. CONCLUSIONS: When esophageal perforation caused by EMR is immediately recognized, endoscopic application of metallic clips is appropriate therapy. However, patients must be carefully monitored for the development of generalized mediastinitis. |
| |
Keywords: | |
本文献已被 ScienceDirect PubMed 等数据库收录! |
|