Usefulness of administration of SPIO prior to RF ablation for evaluation of the therapeutic effect: an experimental study using miniature pigs |
| |
Authors: | Kakite Suguru Fujii Shinya Nakamatsu Satoru Kanasaki Yoshiko Yamashita Eijirou Matsusue Eiji Ouchi Yasufumi Kaminou Toshio Tokunaga Shiho Koda Masahiko Ogawa Toshihide |
| |
Affiliation: | a Division of Radiology, Department of Pathophysiological and Therapeutic Science, Faculty of Medicine, Tottori University, 36-1 Nishi-cho, Yonago 683-8503, Japan b Division of Medicine and Clinical Science, Department of Multidisciplinary Internal Medicine, Faculty of Medicine, Tottori University, 36-1 Nishi-cho, Yonago 683-8503, Japan |
| |
Abstract: | ObjectivesTo evaluate the usefulness of administration of superparamagnetic iron oxide (SPIO) and magnetic resonance (MR) imaging for assessing the efficacy of radiofrequency (RF) liver ablation.Material and methodsUsing a protocol approved by the animal research committee of our university, nine RF liver ablations were performed in three miniature pigs. Six ablations were performed after administration of SPIO in two pigs (group A). Three ablations were performed in the other pig without administration of SPIO (group B). All pigs were sacrificed 4 days after the procedure. Harvested livers were scanned with a 1.5 T MR system before and after fixation with 10% buffered formalin, and MR images were precisely compared with histological specimens.ResultsThere were no histological differences between the two groups. All ablated liver lesions showed coagulation necrosis at the external layer. There were no viable cells inside the coagulation necrosis. All ablated lesions had a hypointense rim on fast low angle shot (FLASH) images. The rims of group A were thicker than those of group B. The rims of group B corresponded histologically to congestion and hemorrhagic necrosis area. The rims of the group A corresponded to hemorrhagic necrosis and coagulation necrosis areas. In group A, the hypointense rim reflected necrotic Kupffer cells that took up SPIO before RF liver ablation.ConclusionAdministration of SPIO made it possible to precisely evaluate ablated liver parenchyma by hypointense rim on FLASH images. This method is helpful for the evaluation of safety margin after RF ablation for liver tumors. |
| |
Keywords: | Magnetic resonance imaging Superparamagnetic iron oxide Radiofrequency ablation Liver |
本文献已被 ScienceDirect PubMed 等数据库收录! |
|