A bacterial barrier dressing for skin donor sites |
| |
Authors: | Paul Nathan Edward C. Robb Bruce G. MacMillan |
| |
Affiliation: | The Shriners Burns Institute, Cincinnati Unit, and Departments of Physiology and Surgery, University of Cincinnati College of Medicine, USA |
| |
Abstract: | Although most skin donor sites heal uneventfully, some surgically prepared open areas become contaminated and are converted to full-thickness wounds. Accordingly, a synthetic bacterial barrier dressing (Hydron Burn Bandage) applied as a spray or a preformed sheet was compared with fine mesh gauze application on skin donor sites in a series of 50 burned children. Six of 19 control wounds demonstrated some bacterial contaminants. Only 2 out of 22 donor sites covered within 5 h after preparation contained any detectable bacterial contaminants. The Hydron bandage applied to skin donor sites adhered well, was easily removed at about 12 days and produced a barrier to bacterial contamination during the healing period. |
| |
Keywords: | Requests for reprints should be addressed to: Dr Paul Nathan Shriners Burns Institute 202 Goodman Street Cincinnati Ohio 45219 USA |
本文献已被 ScienceDirect 等数据库收录! |