首页 | 本学科首页   官方微博 | 高级检索  
     


A comparison of several modulated radiotherapy techniques for head and neck cancer and dosimetric validation of VMAT
Authors:Florian Stieler  Dirk WolffHeike Schmid  Grit WelzelFrederik Wenz  Frank Lohr
Affiliation:Department of Radiation Oncology, University of Heidelberg, Germany
Abstract:

Purpose

Volumetric modulated arc therapy (VMAT) has the potential to shorten treatment times for fluence modulated radiotherapy. We compared dose distributions of VMAT, step-and-shoot IMRT and serial tomotherapy for typical head and neck (H&N) planning target volumes (PTV) with sparing of one parotid, a complex paradigm and a situation often encountered in H&N radiotherapy. Finally, we validated the dosimetric accuracy of VMAT delivery.

Material and methods

Based on CT datasets of 10 patients treated for H&N cancer (PTV1:60 Gy/PTV2:56 Gy) with IMRT (7/9 fields), serial tomotherapy (MIMiC) and VMAT were compared with regard to plan quality and treatment efficiency. Plan quality was assessed by calculating homogeneity/conformity index (HI/CI), mean dose to parotid and brain stem and the maximum dose to the spinal cord. For plan efficiency evaluation, total treatment time (TTT) and number of monitor units (MU) were considered. A dosimetric evaluation of VMAT was performed using radiosensitive film, ion chamber and 2D-array.

Results

For MIMiC/IMRT7F/IMRT9F/VMAT, mean CI was 1.98/2.23/2.23/1.82, HIPTV1 was 1.12/1.20/1.20/1.11 and HIPTV2 was 1.11/1.15/1.13/1.12. Mean doses to the shielded parotid were 19.5 Gy/14.1 Gy/13.9 Gy/14.9 Gy and the spinal cord received maximum doses of 43.6 Gy/40.8 Gy/41.6 Gy/42.6 Gy. The mean MU’s were 2551/945/925/521 and the mean TTT was 12.8 min/7.6 min/8.5 min/4.32 min. The ion chamber measurements showed an absolute deviation of 0.08 ± 1.10% and 98.45 ± 3.25% pixels passed γ-analyses for 3%/3 mm and 99.95 ± 0.09% for 5%/5 mm for films. 2D-array measurements reported an agreement for 3%/3 mm of 95.65 ± 2.47%-98.33 ± 0.65% and for 5%/5 mm 99.79 ± 0.24%-99.92 ± 0.09% depending on the measurement protocol.

Conclusion

All treatment paradigms produced plans of excellent quality and dosimetric accuracy with IMRT providing best OAR sparing and VMAT being the most efficient treatment option in our comparison of treatment plans with high complexity.
Keywords:Volumetric modulated arc therapy (VMAT)   Intensity modulated radiotherapy (IMRT)   Sequential tomotherapy   Head and neck cancer
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号