首页 | 本学科首页   官方微博 | 高级检索  
     


Comparison of intensity-modulated radiotherapy, adaptive radiotherapy, proton radiotherapy, and adaptive proton radiotherapy for treatment of locally advanced head and neck cancer
Authors:Charles B. Simone IIDavid Ly,Tu D. DanJohn Ondos,Holly NingArnaud Belard,John O&rsquo  ConnellRobert W. Miller,Nicole L. Simone
Affiliation:a National Cancer Institute, Radiation Oncology Branch, Bethesda, USA
b Henry M. Jackson Foundation for the Advancement of Military Medicine, Washington, USA
c Walter Reed Army Medical Center, Radiation Oncology, Washington, DC, USA
Abstract:

Background and purpose

Various radiotherapy planning methods for locally advanced squamous cell carcinoma of the head and neck (SCCHN) have been proposed to decrease normal tissue toxicity. We compare IMRT, adaptive IMRT, proton therapy (IMPT), and adaptive IMPT for SCCHN.

Materials and methods

Initial and re-simulation CT images from 10 consecutive patients with SCCHN were used to quantify dosimetric differences between photon and proton therapy. Contouring was performed on both CTs, and plans (n = 40 plans) and dose-volume histograms were generated.

Results

The mean GTV volume decreased 53.4% with re-simulation. All plans provided comparable PTV coverage. Compared with IMRT, adaptive IMRT significantly reduced the maximum dose to the mandible (p = 0.020) and mean doses to the contralateral parotid gland (p = 0.049) and larynx (p = 0.049). Compared with IMRT and adaptive IMRT, IMPT significantly lowered the maximum doses to the spinal cord (p < 0.002 for both) and brainstem (p < 0.002 for both) and mean doses to the larynx (p < 0.002 for both) and ipsilateral (p = 0.004 IMRT, p = 0.050 adaptive) and contralateral (p < 0.002 IMRT, p = 0.010 adaptive) parotid glands. Adaptive IMPT significantly reduced doses to all critical structures compared with IMRT and adaptive IMRT and several critical structures compared with non-adaptive IMPT.

Conclusions

Although adaptive IMRT reduced dose to several normal structures compared with standard IMRT, non-adaptive proton therapy had a more favorable dosimetric profile than IMRT or adaptive IMRT and may obviate the need for adaptive planning. Protons allowed significant sparing of the spinal cord, parotid glands, larynx, and brainstem and should be considered for SCCHN to decrease normal tissue toxicity while still providing optimal tumor coverage.
Keywords:Head and neck cancer   Proton therapy   Adaptive radiotherapy   IMRT   Treatment planning
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号