Differences in ion release after ceramic-on-ceramic and metal-on-metal total hip replacement. Medium-term follow-up |
| |
Authors: | Savarino L Greco M Cenni E Cavasinni L Rotini R Baldini N Giunti A |
| |
Institution: | The Rizzoli Orthopaedic Institute, Bologna, Italy. lucia.savarino@ior.it |
| |
Abstract: | Modern metal-on-metal bearings produce less wear debris and osteolysis, but have the potential adverse effect of release of ions. Improved ceramic-on-ceramic bearings have the lowest wear of all, but the corrosion process has not been analysed. Our aim was to measure the serum ion release (ng/ml) in 23 patients having stable hip prostheses with a ceramic-on-ceramic coupling (group A) and to compare it with the release in 42 patients with a metal-on-metal bearing (group B) in the medium term. Reference values were obtained from a population of 47 healthy subjects (group C). The concentrations of chromium, cobalt, aluminium and titanium were measured. There was a significant increase of cobalt, chromium and aluminium levels (p < 0.05) in group B compared with groups A and C. Group A did not differ significantly from the control group. Despite the apparent advantage of a metal-on-metal coupling, especially in younger patients with a long life expectancy, a major concern arises regarding the extent and duration of ion exposure. For this reason, the low corrosion level in a ceramic-on-ceramic coupling could be advantageous. |
| |
Keywords: | |
本文献已被 PubMed 等数据库收录! |
|