首页 | 本学科首页   官方微博 | 高级检索  
检索        

含氟人工唾液对选择性激光熔积钴铬合金耐腐蚀性的影响
引用本文:曾 丽,张 勇,杨 旭,等.含氟人工唾液对选择性激光熔积钴铬合金耐腐蚀性的影响[J].上海交通大学学报(医学版),2014(3):314-317,328.
作者姓名:曾 丽  张 勇  杨 旭  
作者单位:[1]上海交通大学医学院附属第九人民医院口腔特需门诊上海市口腔医学承点实验室,上海200011 [2]上海复星医疗系统有限公司,复星&贝格数宁化加工中心,上海200011
基金项目:上海市科委资助项目(12441903001.13140902701)
摘    要:目的观察含氟人工唾液对选择性激光熔积技术(SLM)制作的钴铬合金耐腐蚀性的影响。方法将具有相同成分的钻铬合金粉未和金属块,分别运用SLM技术(SLM组)和铸造工艺(对照组)制作试件,每组40个。分别在pH为5.0和2.5以及模拟口腔含氟0、0.05%、0.10%和0.20%的条件下,将试件置于Fusayam人工唾液中浸泡24h。采用极化曲线Tafel外延法求得两组试样的极化阻力Rp值,比较两组试件的耐腐蚀性。结果pH值为5.0时,在含氟0和0.05%的条件下,两组间Rp值比较差异无统计学意义(P〉0.05);而在含氟0.1%和0.2%的条件下,SLM组的Rp值显著大于对照组(P〈0.05),当pH为2.5时,往含氟0、0.05%、0.10%和0.20%的条件下,SLM组的Rp值均品著大于对照组(P〈0.05).结论氟化物能影响铺铬合金的耐腐蚀性能,SLM钴铬合会的耐腐蚀性优于铸造钻铬合金。

关 键 词:选择性激光熔积技术  钴铬合金  氟化物  耐腐蚀性

Effects of different fluorine-containing oral artificial saliva solution on anti-corrosion behavior of selective laser melting cobalt-chromium alloy
ZENG Li,ZHANG Yong,YANG Xu,XIN Xian-zhen,WEI Bin.Effects of different fluorine-containing oral artificial saliva solution on anti-corrosion behavior of selective laser melting cobalt-chromium alloy[J].Journal of Shanghai Jiaotong University:Medical Science,2014(3):314-317,328.
Authors:ZENG Li  ZHANG Yong  YANG Xu  XIN Xian-zhen  WEI Bin
Institution:1. Department of Stomatology Special Consultation Clininc, the Ninth People Hospital, Shanghai Jiao Tong University School ,f Medicine, Shanghai Key Laboratory of Stomatology, Shanghai 200011, China; 2. Shanghai Foshion & BEGO CAD/CAM Center, Shanghai Foshion Dental Division, Shanghai 200011, China)
Abstract:Objective To evaluate the effects of different fluoride-containing artificial saliva solution on the corrosion of the dental cobalt-chromium (Co-Cr) alloy fabricated by selective laser melting (SLM). Methods The study involved two groups, each group has 40 cylinder specimens and all specimens were fabricated by the same Co-Cr alloy. One group adopted SLM, while the other group used the cast method. Under conditions of two different pHs (2.5 and 5.0) and four different fluoride-containing artificial saliva solution concentration (0, 0. 05%, 0. 1%, and 0.2% ), polarization curve tests were performed to compare the anti-corrosion ability of two groups. Results For pH of 5. 0 (fluoride- containing artificial saliva solution concentrations were 0 and 0. 05% ), differences of Rp values between two groups were not statistically significant (P 〉 0. 05). For pH of 5. 0 (fluoride-containing artificial saliva solution concentration were 0. 1% and 0. 2% ) and pH of 2.5 (fluoride-containing artificial saliva solution concentration were 0, 0. 05%, 0. 1%, and 0. 2% ), the Rp value of SLM specimens were significantly higher than those of the cast ones (P 〈 0. 05). Conclusion Fluorine can affect the anti-corrosion ability of Co-Cr alloy. SLM specimens exhibited a significantly better anti-corrosion ability than cast ones.
Keywords:selective laser melting  Cobalt-chromium alloy  fluoride  anti-corrosion behavior
本文献已被 CNKI 维普 等数据库收录!