首页 | 本学科首页   官方微博 | 高级检索  
     


Treatment of distal radius fractures with a low-profile dorsal plating system: an outcomes assessment
Authors:Simic Paul M  Robison Jason  Gardner Michael J  Gelberman Richard H  Weiland Andrew J  Boyer Martin I
Affiliation:Southern California Orthopaedic Institute, Van Nuys, CA, USA.
Abstract:PURPOSE: To evaluate objective functional and radiographic outcomes after internal fixation of acute, displaced, and unstable fractures of the distal aspect of the radius in adults by using a low-profile dorsal plating system. Our hypothesis was that the low-profile dorsal plating system would allow for a reduction of extensor tendon irritation and pain and provide stable osseous fixation. METHODS: Sixty consecutive unstable fractures in 59 patients were treated by open reduction internal fixation using a low-profile dorsal plating system. There were 29 type A, 14 type B, and 8 type C fractures (AO classification system). Fifty patients with 51 fractures returned for outcomes assessment by physical examination, plain radiographs, and completion of a validated musculoskeletal function assessment questionnaire. The minimum follow-up period was 1 year; the mean follow-up period was 24 months. Clinical evaluation was performed and plain radiographs were assessed for maintenance of immediate postoperative reduction and implant position. Objective functional assessment was obtained through the Disabilities of the Arm, Shoulder, and Hand questionnaire. RESULTS: Outcomes analysis showed no cases of extensor tendon irritation or rupture. Hardware removal was performed in 1 patient but no extensor tendon irritation or rupture was evidenced. The mean Disabilities of the Arm, Shoulder, and Hand score was 11.9; implant-related discomfort was minimal. All patients had an excellent (31 patients) or good (19 patients) result according to the scoring system of Gartland and Werley. The mean active range of motion was greater than 80% of that of the contralateral wrist in flexion/extension, pronation/supination, and ulnar/radial deviation. Extensor tendon function was unimpaired in all patients. Grip and pinch strength averaged 90% and 94% of the contralateral sides, respectively. Radiographic evaluation showed no change in fracture reduction or implant position. CONCLUSIONS: The treatment of distal radius fractures with a low-profile stainless steel dorsal plating system is a safe and effective method that provides stable internal fixation and allows for full extensor tendon glide and full metacarpophalangeal joint motion. Objective outcome testing showed uniformly good to excellent recovery of wrist and hand function in all patients. TYPE OF STUDY/LEVEL OF EVIDENCE: Therapeutic, Level IV.
Keywords:Distal radius   dorsal plating   low-profile plate
本文献已被 ScienceDirect PubMed 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号