On-Line Automated Border Detection for Echocardiographic Quantification of Right Ventricular Size and Function in Children
Authors:W.A. Helbing  H.G. Bosch  C. Maliepaard  K.H. Zwinderman  S.A. Rebergen  J. Ottenkamp  A. de Roos  J.H.C. Reiber
Affiliation:(1) Department of Pediatrics (Division of Pediatric Cardiology), University Hospital Leiden, Albinusdreetz, J-6-S, 2333 ZA Leiden, The Netherlands, NL;(2) Department of Diagnostic Radiology and Nuclear Medicine, University Hospital Leiden, Albinusdreetz, J-6-S, 2333 ZA Leiden, The Netherlands, NL;(3) Department of Medical Statistics, University Hospital Leiden, Albinusdreetz, J-6-S, 2333 ZA Leiden, The Netherlands, NL
Abstract:Rapid, accurate assessment of right ventricular (RV) size is important for the management of children with congenital heart disease. The usefulness of the Acoustic Quantification system of automated border detection (ABD) and on-line quantification (AQ) for assessment of RV size was tested in 36 children. AQ data were compared to ``corrected AQ' measurements (after correction for cavity areas erroneously included in the region of interest) required for AQ. Furthermore, the influence of necessary changes to gain settings was tested in ``lateral gain control' (LGC) images obtained by removal of ABD overlays. All results were compared to conventional echocardiography (echo), and agreement with magnetic resonance imaging (MRI) RV areas was assessed. Systematic differences (±) limits of agreement with MRI (transverse plane) for conventional echo and AQ (apical four-chamber view) were as follows: end-diastolic −0.8 ± 3.8 (conventional echo) versus −1.7 ± 4.6 (AQ) cm2/m2 (p < 0.001); end-systolic −1.3 ± 3.2 versus −4.9 ± 5.8 (AQ) cm2/m2 (p < 0.001); fractional area change 7.8 ± 17.0% versus 26.9 ± 31.4% (AQ) (p < 0.001). Differences between conventional echo, LGC, and corrected AQ areas were not statistically significant. The best agreement between MRI and echocardiography was with conventional echo. We conclude that automated border detection of the RV can be performed successfully with the AQ system at a fixed point in the cardiac cycle. For adequate assessment of RV function manual corrections of online AQ results are still required, which results in an important reduction of the time gain of on-line quantification.
Keywords:: Right ventricular function —   Congenital heart disease —   Echocardiograph —   Automated border detection —   Acoustic quantification
本文献已被 SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号