首页 | 本学科首页   官方微博 | 高级检索  
检索        

模型基础的迭代重建算法优化腹部静脉成像质量
引用本文:曹宏志,刘岳峰,梁福兵,宋建文.模型基础的迭代重建算法优化腹部静脉成像质量[J].中国医学影像技术,2013,29(3):472-475.
作者姓名:曹宏志  刘岳峰  梁福兵  宋建文
作者单位:北京市房山区第一医院放射科,北京,102400
摘    要:目的 探讨应用模型基础的迭代重建(MBIR)算法优化腹部CT静脉成像(CTV)图像质量的价值.方法 应用自动管电流调节技术对27例可疑腹部病变患者行腹部CT扫描,分别采用滤波反投影技术(FBP组)、50%自适应统计迭代重建(ASiR组)和MBIR(MBIR组)3种算法对原始数据进行重建;测量背部肌肉、背部脂肪、肝实质、胰腺实质、脾实质的噪声及CT值,计算门静脉、胰静脉、脾静脉及下腔静脉的CNR;采用5分制对图像质量进行评分.采用方差分析和秩和检验对数据进行统计学分析.结果 3组图像CT值的差异无统计学意义(P均>0.05).MBIR组图像噪声低于ASiR组(P<0.001),而二者均低于FBP组(P均<0.05);与FBP组图像相比,ASiR组和MBIR组图像噪声分别降低28.61%和53.53%,CNR分别增加40.92%和158.85%.MBIR组、ASiR组和FBP组的主观评分分别为(4.64±0.31)分、(3.74±0.54)分及(3.22±0.60)分,差异有统计学意义(P=0.008).结论 MBIR重建算法可以明显提高腹部CTV图像质量,并具有降低腹部CTV辐射剂量的潜能.

关 键 词:体层摄影术  X线计算机  腹部  静脉造影术  自动管电流调节  模型  迭代重建
收稿时间:7/2/2012 12:00:00 AM
修稿时间:2012/12/21 0:00:00

Model-based iterative reconstruction in optimizing image quality of abdomen CT venography
CAO Hong-zhi,LIU Yue-feng,LIANG Fu-bing and SONG Jian-wen.Model-based iterative reconstruction in optimizing image quality of abdomen CT venography[J].Chinese Journal of Medical Imaging Technology,2013,29(3):472-475.
Authors:CAO Hong-zhi  LIU Yue-feng  LIANG Fu-bing and SONG Jian-wen
Institution:Department of Radiology, the First Hospital of Fangshan District, Beijing 102400, China;Department of Radiology, the First Hospital of Fangshan District, Beijing 102400, China;Department of Radiology, the First Hospital of Fangshan District, Beijing 102400, China;Department of Radiology, the First Hospital of Fangshan District, Beijing 102400, China
Abstract:Objective: To explore the value of model-based iterative reconstruction (MBIR) in optimizing image quality of abdomen CT venography (CTV). Methods: Totally 27 consecutive patients were chosen and underwent plain and contrast-enhanced abdomen CT with automated tube current modulation. The images were reconstructed with filtered back projection (FBP group), adaptive statistical iterative reconstruction (ASiR group) 50% and MBIR (MBIR group), respectively. Image noises and CT values of muscle, fat tissue, liver, kidney and spleen, as well as CNR for portal veins, inferior vena cava, pancreatic veins and splenic veins were measured. The image quality was evaluated using 5-point scale. Those results among the 3 different reconstructions were compared by one-way ANOVA and Wilcoxon signed-rank tests. Results: CT value in three groups had no significant difference (P>0.05). The image noise in MBIR group was lower than that in ASiR group (P<0.001), and both of them were lower than that in FBP group (both P<0.05). Compared with FBP group, the average SD reduction rate of ASiR group and MBIR group was 28.61% and 53.53%, the increase rate of CNR was 40.92% and 158.85%, respectively. The average subjective score of MBIR group, ASiR group and FBP group was 4.64±0.31, 3.74±0.54 and 3.22±0.60, respectively (P=0.008). Conclusion: MBIR can improve the overall image quality and has potential in decreasing radiation dose of abdomen CTV.
Keywords:Tomography  X-ray computed  Abdomen  Phlebography  Automated tube current modulation  Models  Iterative reconstruction
本文献已被 万方数据 等数据库收录!
点击此处可从《中国医学影像技术》浏览原始摘要信息
点击此处可从《中国医学影像技术》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号