首页 | 本学科首页   官方微博 | 高级检索  
     

Array多焦点人工晶状体的初步观察
引用本文:林振德 冯波 等. Array多焦点人工晶状体的初步观察[J]. 眼科新进展, 2001, 21(1): 30-32
作者姓名:林振德 冯波 等
作者单位:林振德(510060 广州市,中山医科大学中山眼科中心)      冯波(510060 广州市,中山医科大学中山眼科中心)      刘奕志(510060 广州市,中山医科大学中山眼科中心)      程冰(510060 广州市,中山医科大学中山眼科中心)      邹玉平(510060 广州市,中山医科大学中山眼科中心)
摘    要:目的 初步评估Array多焦点人工晶状体的有效性。方法 从我院住院的白内障患者中选择合适的病例。男4例4眼,女6例7眼,行标准超声乳化白内障摘出术联合Array人工晶状体植入术,观察患者术后的远、近视力,角膜曲率,及视觉症状,结果 术后最好视力平均值:非矫正远视力为0.8,最佳矫正远视力为0.9,非矫正近视力为0.5,用视远的矫正度数矫正的近视力为0.6,最佳矫正近视力为0.9。角膜散光术前及术后无法小于1.5D。1例(9.1%)患者夜间有眩光。结论 Array人工晶状体可以同时提供良好的远视力和近视力,进一步的结论还有待大组病例的长期观察。

关 键 词:超声乳化术 多焦点人工晶状体 白内障 Array
文章编号:1003-5141(2001)01-0030-03
修稿时间:2000-10-08

Preliminary clinicalobservation of Array multifocal intraocular lens implantation
LIN Zhen De,FENG Bo,LIU Yi Zhi,CHENG Bing,ZOU Yu PingFromtheZhongshanOphthalmicCenterofSunYat-SenUniversityofMedicalSciences,Guangzhou,GuangdongProvince,China. Preliminary clinicalobservation of Array multifocal intraocular lens implantation[J]. Recent Advances in Ophthalmology, 2001, 21(1): 30-32
Authors:LIN Zhen De  FENG Bo  LIU Yi Zhi  CHENG Bing  ZOU Yu PingFromtheZhongshanOphthalmicCenterofSunYat-SenUniversityofMedicalSciences  Guangzhou  GuangdongProvince  China
Affiliation:LIN Zhen De,FENG Bo,LIU Yi Zhi,CHENG Bing,ZOU Yu PingFromtheZhongshanOphthalmicCenterofSunYat-SenUniversityofMedicalSciences,Guangzhou510060,GuangdongProvince,China
Abstract:Objective To evaluate the clinical effects of Array multifocal intraocular lens.Methods Ten cases (11 eyes) of cataract patients, including 4 males (4 eyes) and 6 females(7 eyes), were involved in this study. All patients underwent standard phacoemulsification with Array multifocal intraocular lens implantation. The complications during operation, postoperative distant visual acuity, near visual acuity, corneal curvature and visual symptoms were observed. Results The mean value of best postoperative visual acuity was recorded as follows: uncorrected distant visual acuity was0 8, the best corrected distant visual acuity was 0.9, uncorrected near visual acuity was 0.5, near visual acuity with distant corrected was 0 6, the best corrected near visual acuity was 0.9. The astigmatism of cornea was less than 1 5D pre operatively and post operatively. One patient (9.1%) complained glare. Conclusion Array multifocal intraocular lens can provide good distant and near visual acuity. With more cases and longer follow up, we can draw a further conclusion.
Keywords:ultrasonic phacoemulsification  multifocal intraocular lens  cataract  
本文献已被 CNKI 维普 等数据库收录!