首页 | 本学科首页   官方微博 | 高级检索  
     


Explicit Finite Element Models Accurately Predict Subject-Specific and Velocity-Dependent Kinetics of Sideways Fall Impact
Authors:Ingmar Fleps  Pierre Guy  Stephen J Ferguson  Peter A Cripton  Benedikt Helgason
Affiliation:1. Institute for Biomechanics, ETH Zürich, Zürich, Switzerland;2. Division of Orthopaedic Trauma, Department of Orthopaedics, University of British Columbia, Vancouver, BC, Canada;3. Orthopaedics and Injury Biomechanics Group, Department of Mechanical Engineering and Orthopaedics and School of Biomedical Engineering, University of British Columbia, Vancouver, BC, Canada
Abstract:The majority of hip fractures in the elderly are the result of a fall from standing or from a lower height. Current injury models focus mostly on femur strength while neglecting subject-specific loading. This article presents an injury modeling strategy for hip fractures related to sideways falls that takes subject-specific impact loading into account. Finite element models (FEMs) of the human body were used to predict the experienced load and the femoral strength in a single model. We validated these models for their predicted peak force, effective pelvic stiffness, and fracture status against matching ex vivo sideways fall impacts (n = 11) with a trochanter velocity of 3.1 m/s. Furthermore, they were compared to sideways impacts of volunteers with lower impact velocities that were previously conducted by other groups. Good agreement was found between the ex vivo experiments and the FEMs with respect to peak force (root mean square error [RMSE] = 10.7%, R2 = 0.85) and effective pelvic stiffness (R2 = 0.92, RMSE = 12.9%). The FEMs were predictive of the fracture status for 10 out of 11 specimens. Compared to the volunteer experiments from low height, the FEMs overestimated the peak force by 25% for low BMI subjects and 8% for high BMI subjects. The effective pelvic stiffness values that were derived from the FEMs were comparable to those derived from impacts with volunteers. The force attenuation from the impact surface to the femur ranged between 27% and 54% and was highly dependent on soft tissue thickness (R2 = 0.86). The energy balance in the FEMS showed that at the time of peak force 79% to 93% of the total energy is either kinetic or was transformed to soft tissue deformation. The presented FEMs allow for direct discrimination between fracture and nonfracture outcome for sideways falls and bridge the gap between impact testing with volunteers and impact conditions representative of real life falls. © 2019 American Society for Bone and Mineral Research.
Keywords:FRACTURE RISK ASSESSMENT  BIOMECHANICS  ORTHOPAEDICS  FRACTURE PREVENTION  BONE
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号