首页 | 本学科首页   官方微博 | 高级检索  
检索        

Comparison of higher-order aberrations and contrast sensitivity between Tecnis Z9001 and CeeOn 911A intraocular lenses: a prospective randomized study
作者姓名:Chen WR  Ye HH  Qian YY  Yang WH  Lin ZH
作者单位:[1]Zhongshan Ophthalmic Center of Sun Yat-sen University, Guangzhou 510060, China [2]Department of Ophthalmology, People's Hospital of Dongshan District, Guangzhou 510080, China
摘    要:Background The advent of wavefront technology in the past five years has provided some insight into the optical outcomes of cataract surgery. The Tecnis Z9001 intraocular lens (Tecnis IOL, AMO) with a modified prolate anterior surface was claimed to reduce or even eliminate ocular spherical aberration to improve the visual quality. The purpose of this study was to determine whether Tecnis IOLs can improve the quality of vision as evaluated by measuring visual acuity, wavefront aberration, and contrast sensitivity. Methods In an intraindividual prospective study, 20 patients with bilateral cataract were randomly assigned to receive a modified prolate anterior surface IOL (Tecnis Z9001, AMO) in one eye and a biconvex spherical surface IOL (CeeOn 911A, AMO) in the other. After 3 months, the following were investigated: best corrected visual acuity, pupil diameter, photopic and mesopic contrast sensitivity, and wavefront aberration of the whole eye (ocular), cornea, and internal plane. Results The differences in the best corrected visual acuity and pupil diameter between the two groups were not statistically significant. Negative 4th-order spherical aberration (Z4^0) was found in the Tecnis group, whereas positive Z4^0 found in the CeeOn group for the internal and ocular plane. Statistically significant differences were found at the ocular higher-aberrations between the two IOLs. Contrast sensitivity testing showed significantly better results in the Tecnis group at visual angles higher than 1.0 degree under photopic conditions and at visual angles higher than 1.6 degree under mesopic conditions both without glare and with glare in comparison with the CeeOn group. Conclusions The Tecnis Z9001 IOL with a modified prolate anterior surface produces negative spherical aberration and consequently reduces the higher-order aberrations in pseudophakic eyes. This leads to enhanced contrast sensitivity and improved functional vision compared to conventional spherical IOLs.

关 键 词:灵敏度  眼内疾病  检查方法  病理
收稿时间:2006-03-16

Comparison of higher-order aberrations and contrast sensitivity between Tecnis Z9001 and CeeOn 911A intraocular lenses: a prospective randomized study
Chen WR,Ye HH,Qian YY,Yang WH,Lin ZH.Comparison of higher-order aberrations and contrast sensitivity between Tecnis Z9001 and CeeOn 911A intraocular lenses: a prospective randomized study[J].Chinese Medical Journal,2006,119(21):1779-1784.
Authors:Chen Wei-rong  Ye He-hua  Qian Yi-yong  Yang Wen-hui  Lin Zhi-hong
Institution:1. Zhongshan Ophthalmic Center of Sun Yat-sen University,Guangzhou 510060, China
2. Department of Ophthalmology, People's Hospital of Dongshan District, Guangzhou 510080, China
Abstract:Background The advent of wavefront technology in the past five years has provided some insight into the optical outcomes of cataract surgery. The Tecnis Z9001 intraocular lens (Tecnis IOL, AMO) with a modified prolate anterior surface was claimed to reduce or even eliminate ocular spherical aberration to improve the visual quality. The purpose of this study was to determine whether Tecnis IOLs can improve the quality of vision as evaluated by measuring visual acuity, wavefront aberration, and contrast sensitivity.Methods In an intraindividual prospective study, 20 patients with bilateral cataract were randomly assigned to receive a modified prolate anterior surface IOL (Tecnis Z9001, AMO) in one eye and a biconvex spherical surface IOL (CeeOn 911A, AMO) in the other. After 3 months, the following were investigated: best corrected visual acuity, pupil diameter, photopic and mesopic contrast sensitivity, and wavefront aberration of the whole eye (ocular), cornea, and internal plane.Results The differences in the best corrected visual acuity and pupil diameter between the two groups were not statistically significant. Negative 4th-order spherical aberration (Z(4)(0)) was found in the Tecnis group, whereas positive Z(4)(0) found in the CeeOn group for the internal and ocular plane. Statistically significant differences were found at the ocular higher-aberrations between the two IOLs. Contrast sensitivity testing showed significantly better results in the Tecnis group at visual angles higher than 1.0 degree under photopic conditions and at visual angles higher than 1.6 degree under mesopic conditions both without glare and with glare in comparison with the CeeOn group.Conclusions The Tecnis Z9001 IOL with a modified prolate anterior surface produces negative spherical aberration and consequently reduces the higher-order aberrations in pseudophakic eyes. This leads to enhanced contrast sensitivity and improved functional vision compared to conventional spherical IOLs.
Keywords:aspheric intraocular lens  higher-order aberrations  contrast sensitivity
本文献已被 CNKI 维普 万方数据 PubMed 等数据库收录!
点击此处可从《中华医学杂志(英文版)》浏览原始摘要信息
点击此处可从《中华医学杂志(英文版)》下载免费的PDF全文
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号