首页 | 本学科首页   官方微博 | 高级检索  
检索        


Polymer-Free Biolimus-Eluting Stents or Polymer-Based Zotarolimus-Eluting Stents for Coronary Bifurcation Lesions
Institution:1. MedStar Center for Health Equity Research, MedStar Health Research Institute, United States of America;2. Georgetown University, United States of America;3. MedStar National Center for Human Factors in Healthcare, United States of America;4. MedStar Health Research Institute, United States of America
Abstract:BackgroundA polymer-free biolimus-eluting stent (PF-BES) and a zotarolimus-eluting stent (ZES) recently showed similar clinical profiles and appear to be competing options in specific clinical settings of patients undergoing percutaneous coronary intervention (PCI). Whether they perform similarly also in complex procedural settings as coronary bifurcation lesions remains unaddressed.MethodsAll consecutive patients undergoing coronary bifurcation PCI with PF-BES or the new iteration of the ZES from three large multicenter real-world registries were included. The primary outcome was major adverse cardiovascular events (MACE), a composite of all-cause death, myocardial infarction (MI), target lesion revascularization (TLR) and stent thrombosis (ST). Multiple analyses to adjust for baseline differences were carried out including propensity-score matching, propensity-score stratification and inverse-probability-weighting. Outcomes are reported according to Cox proportional hazard models censored at 400-day follow-up.Results1169 patients treated with PF-BES (n = 440) or ZES (n = 729) on the main branch of a coronary bifurcation lesion were included (mean age 69 ± 11 years, 75.4% male, 53.8% acute coronary syndrome at presentation, 26.6% left main bifurcation, median dual antiplatelet therapy duration 12 range 12–12] months). MACE, all-cause death, TLR and ST tended towards non-statistically higher rates with the PF-BES as compared to the ZES. Higher MI and target vessel revascularization occurrence was observed with PF-BES.ConclusionsIn this large contemporary cohort of patients undergoing coronary bifurcation PCI, the occurrence of MACE was non-statistically different with the use of PF-BES and ZES devices. However, differences favoring the ZES device that may entail clinical relevance were observed. Further studies are needed to confirm these findings and explore whether they remain valid when a short dual antiplatelet therapy is adopted.
Keywords:
本文献已被 ScienceDirect 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号