首页 | 本学科首页   官方微博 | 高级检索  
     

酶免法检测HBeAg假阳性原因探讨
引用本文:王卉,任捷民. 酶免法检测HBeAg假阳性原因探讨[J]. 实用医技杂志, 2002, 9(1): 15-16
作者姓名:王卉  任捷民
作者单位:德州市临床检验中心,山东,德州,253014
摘    要:目的 :探讨酶免法检测 HBe Ag假阳性的原因。方法 :标本分别采用 30 0 0 rpm离心 0 ,6 ,9,12 ,15 ,18m in,取上清液检测。结果 :标本经离心 6 m im以上 ,本底皆干净 ,没有 HBe Ag假阳性结果。结论 :经过充分离心处理的标本无 HBe Ag假阳性检出。

关 键 词:HBeAg  酶免法  离心  假阳性

Discussion on Causes of HBeAg False Positive Reaction Detected by Enzyme Immunoassay
WANG Hui,REN Jie min. Discussion on Causes of HBeAg False Positive Reaction Detected by Enzyme Immunoassay[J]. Journal of Practical Medical Techniques, 2002, 9(1): 15-16
Authors:WANG Hui  REN Jie min
Abstract:This paper discusses the causes of HBeAg false positive reaction detected by enzyme immunoassay. The serum samples were separated by centrifugation at the speed of 3,000 rpm respectively for 0, 6, 12, 15 and 18 minutes, obtaining supernatant fluid for examination. Consequently, after centrifugalization for over 6 minutes, the background was very clean and no HBeAg false positive reaction was found. In conclusion, no HBeAg false positive reaction was detected from the centrifugalized samples.
Keywords:HBeAg  enzyme immunoassay  centrifugalization  false positive reaction  
本文献已被 CNKI 维普 万方数据 等数据库收录!