The novel infra‐pectineal buttress plates used for internal fixation of elderly quadrilateral surface involved acetabular fractures |
| |
Authors: | Yizhou Wan Sheng Yao Yan Ma Lian Zeng Yulong Wang Yanzhen Qu Guixiong Huang Xiaodong Guo Kaifang Chen |
| |
Affiliation: | 1. Department of Orthopaedics, Union Hospital, Tongji Medical College, Huazhong University of Science & Technology, Wuhan China ; 2. The second clinical medical college, Tongji Medical College, Huazhong University of Science & Technology, Wuhan China |
| |
Abstract: | ObjectivesIn geriatric acetabular fractures, the quadrilateral surface (QLS) was frequently involved in acetabular fracture patterns and accompanied by medial displacement. It was important to buttress the medial displaced QLS and reconstruct the congruity of the affected acetabulum. To evaluate the clinical effectiveness of the novel infra‐pectineal quadrilateral surface buttress plates for the treatment of geriatric acetabular fractures.MethodsTwenty‐three geriatric patients who were treated for acetabular fractures involving QLS with the novel infra‐pectineal buttress plates (NIBP) through a single supra‐ilioinguinal approach between January 2015 and June 2019 were retrospectively analyzed; all patients received at least 1 year''s follow‐up. All patients were aged ≥60 years old and including 18 males and five females. Radiologic and clinical outcomes of patients involved in the study were collated and analyzed according to the Matta scoring system and the Merle D''Aubigné–Postel scoring system. The functional recovery scoring was compared using q‐test.ResultsAll 23 consecutive patients had relatively satisfactory clinical treatment effectiveness. Average ages, length of incision, operation time, and intraoperative blood loss were 69.8 ± 6.1 years, 12.1 ± 2.6 cm, 166.5 ± 43.5 min, and 500 (500,700) ml, respectively. According to the Matta scoring system, 14 cases of reduction were graded as excellent, five as good, and four as fair. At the last follow‐up, the clinical outcome evaluation was excellent in 13 cases, good in seven cases, and poor in three cases with the use of the Merle D''Aubigné–Postel scoring system. The difference of modified Merle D''Aubigne‐Postel score at 3 months, 6 months and last follow up was statistically significant (F = 21.56, p < 0.05). Postoperative lateral femoral cutaneous nerve injury occurred in three patients and heterotopic ossification occurred in one patient.ConclusionsFor the treatment of geriatric acetabular fractures, the NIBP could provide stable and effective fixation to the QLS involved acetabular fractures, and related satisfactory clinical results with few complications were noted. |
| |
Keywords: | Buttress Geriatric acetabular fractures Internal fixation Medial displacement Quadrilateral surface |
|
|