首页 | 本学科首页   官方微博 | 高级检索  
检索        


Thallium-201 scintigraphy in bone and soft-tissue tumors: a comparison of dynamic, early and delayed scans
Authors:Yoshifumi Sugawara  Takanori Kikuchi  Makoto Kajihara  Takatoshi Semba  Takashi Ochi  Takashi Fujii  Teruhito Mochizuki  Kenshi Sakayama  Shigeru Nakata
Institution:Department of Radiology, Ehime University School of Medicine, Shitsukawa, Toon, Ehime 791-0295, Japan. sugawara@m.ehime-u.ac.jp
Abstract:OBJECTIVE: It has been reported that delayed scan of thallium-201 (201Tl) scintigraphy is useful for differentiating malignant tumors from benign lesions and for evaluating treatment response. However, physiological muscle uptake which usually increases in delayed scans, often makes it difficult to evaluate 201Tl uptake and its washout in bone and soft-tissue tumors. The purpose of this study was to evaluate whether the delayed scan is necessary and whether a dynamic scan is useful in the evaluation of bone and soft-tissue tumors. METHODS: We studied 175 cases of bone and soft-tissue tumors (malignant 45, benign 130). Dynamic scans were acquired every 5 seconds for 10 minutes after 201Tl injection, and time activity curves (TACs) were generated by adaptive smoothing methods. Early and delayed scans were acquired at 10-15 minutes and 2 hours after injection. 201Tl images were visually interpreted and the radioactivity count ratio (T/N) of tumors to normal tissues and washout rate WR = (early T/N - delayed T/N)/early T/N] were defined. RESULTS: When there were no 201Tl uptake in dynamic (n = 67) and early scans (n = 68), no tumor uptake was also appreciated in delayed scans, and all but two cases of negative scans were benign. In 107 lesions, although there were significant differences in T/Ns between malignant and benign lesions both on early scans (2.84 +/- 1.45 vs. 2.05 +/- 1.13, p < 0.05) and delayed scans (2.17 +/- 1.03 vs. 1.58 +/- 0.64, p < 0.05), there was a substantial overlap. The T/Ns decreased in delayed scans (i.e., WR > 0) in 100 of 107 cases due to increase of surrounding muscle uptake, and there was no difference in WR between malignant tumors and benign lesions (0.21 +/- 0.14 vs. 0.19 +/- 0.14). CONCLUSIONS: For evaluating bone and soft-tissue tumors, delayed scan had little clinical usefulness and it may be time consuming. Dynamic scan would be useful for demonstrating the differences between tumor blood flow and 201Tl uptake in tumors.
Keywords:bone tumor  soft-tissue tumor  thallium-201  dynamic scan  delayed scan
本文献已被 PubMed SpringerLink 等数据库收录!
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号